Comparison between Deff and Dw approaches for estimation of size-specific dose in paediatric CT imaging

被引:6
|
作者
Abdulkadir, Muhammad Kabir [1 ,2 ]
Shuaib, Ibrahim Lutfi [1 ]
Nasirudin, R. A. [1 ]
Samsudin, Ahmad Hadif Zaidin [3 ]
Osman, Noor Diyana [1 ,4 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Bertam 13200, Penang, Malaysia
[2] Univ Ilorin, Fac Basic Clin Sci, Dept Med Radiog, Ilorin 240213, Nigeria
[3] Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Kubang Kerian 16150, Kelantan, Malaysia
[4] Univ Sains Malaysia, Adv Med & Dent Inst, Oncol & Radiol Sci Cluster, Bertam 13200, Penang, Malaysia
关键词
Computed tomography; Size-specific dose estimate; Paediatric; Water-equivalent diameter; Effective diameter; ABDOMEN; CHEST; HEAD;
D O I
10.1016/j.radphyschem.2022.110205
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Individual patient size is an important determinant for size-specific dose estimate (SSDE) since the size correction factors are highly dependent on this factor. This study aims to compare two approaches for patient size measurement, the effective diameter (Deff) and water-equivalent diameter (Dw) for estimation of paediatric SSDE. The individual size of 318 paediatric patients (160 head and 158 abdomen CT) aged 0-12 years were measured retrospectively. The patient size was estimated using attenuation-based; Dw approach and geometry-based; Deff approach using anteroposterior (AP) and lateral dimensions on CT axial images. A comparative study was performed to determine the difference and association between these two approaches and their effects on SSDE. The measured patient size using Dw was higher than Deff by an average difference of about 12.8% and 9.3% for head and abdomen, respectively. There were high positive correlations between both approaches, head (R2 = 0.9176) and abdomen (R2 = 0.9491). The difference between measured Dw and Deff were observed by the Bland-Altman's analysis that showed good agreement between Dw and Deff. The overall disparity in SSDE calculated using Deff and Dw was less than 10%. The disparity was higher in head CT SSDE as compared to abdomen CT SSDE, due to lesser correlation between Dw and Deff in head CT scan. Our findings show Deff and Dw to be comparable size metrics for size-specific dose estimate in paediatric CT. The discrepancy between both dose metrics led to slight difference in SSDE calculated using Deff and Dw.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Size-Specific Dose Estimates for Evaluation of Individual Patient Dose in CT Protocol for Renal Colic
    Waszczuk, Lukasz A.
    Guzinski, Maciej
    Czarnecka, Anna
    Sasiadek, Marek J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 100 - 105
  • [42] Dose-Reduced Kidney Stone CT Protocol Optimized with Size-Specific Dose Estimate
    Deng, S.
    Kulkarni, A.
    Harris, N.
    Zimmermann, L.
    Al Helo, R.
    Jordan, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E395 - E395
  • [43] Estimation of radiation dose associated with bone SPECT/CT and establishing local diagnostic reference levels using size-specific dose estimate
    Alrehily, Faisal
    Alshamrani, Abdullah F.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (01)
  • [44] Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy
    Martin, C. J.
    Abuhaimed, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [45] Influence of Water Equivalent Diameter (Dw) Variability Inside the Scan Area on Size-Specific Dose Estimates (SSDE)
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E540 - E540
  • [46] An Investigation of Using a Single CT Image to Assess Size-Specific Dose Estimates (SSDE)
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E514 - E514
  • [47] Patient Size-Specific Analysis of Dose Indexes From CT Lung Cancer Screening
    Fujii, Keisuke
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Christopher
    McNitt-Gray, Michael
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (01) : 144 - 149
  • [48] Size-specific dose estimates in chest, abdomen, and pelvis CT examinations of pediatric patients
    Ozsoykal, Ismail
    Yurt, Aysegul
    Akgungor, Kadir
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2018, 24 (04): : 243 - 248
  • [49] Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan
    Tsai, H.
    Hwang, Y.
    Hu, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3643 - 3643
  • [50] CNN application for automated determination of the patient's size to obtain the size-specific dose estimated in CT
    Hernandez-Davila, Erik R.
    Torres-Garcia, Eugenio
    Aranda-Lara, Liliana
    Roldan-Valadez, Ernesto
    Isaac-Olive, Keila
    Flores-Reyes, Mario
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)