Comparison between Deff and Dw approaches for estimation of size-specific dose in paediatric CT imaging

被引:6
|
作者
Abdulkadir, Muhammad Kabir [1 ,2 ]
Shuaib, Ibrahim Lutfi [1 ]
Nasirudin, R. A. [1 ]
Samsudin, Ahmad Hadif Zaidin [3 ]
Osman, Noor Diyana [1 ,4 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Bertam 13200, Penang, Malaysia
[2] Univ Ilorin, Fac Basic Clin Sci, Dept Med Radiog, Ilorin 240213, Nigeria
[3] Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Kubang Kerian 16150, Kelantan, Malaysia
[4] Univ Sains Malaysia, Adv Med & Dent Inst, Oncol & Radiol Sci Cluster, Bertam 13200, Penang, Malaysia
关键词
Computed tomography; Size-specific dose estimate; Paediatric; Water-equivalent diameter; Effective diameter; ABDOMEN; CHEST; HEAD;
D O I
10.1016/j.radphyschem.2022.110205
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Individual patient size is an important determinant for size-specific dose estimate (SSDE) since the size correction factors are highly dependent on this factor. This study aims to compare two approaches for patient size measurement, the effective diameter (Deff) and water-equivalent diameter (Dw) for estimation of paediatric SSDE. The individual size of 318 paediatric patients (160 head and 158 abdomen CT) aged 0-12 years were measured retrospectively. The patient size was estimated using attenuation-based; Dw approach and geometry-based; Deff approach using anteroposterior (AP) and lateral dimensions on CT axial images. A comparative study was performed to determine the difference and association between these two approaches and their effects on SSDE. The measured patient size using Dw was higher than Deff by an average difference of about 12.8% and 9.3% for head and abdomen, respectively. There were high positive correlations between both approaches, head (R2 = 0.9176) and abdomen (R2 = 0.9491). The difference between measured Dw and Deff were observed by the Bland-Altman's analysis that showed good agreement between Dw and Deff. The overall disparity in SSDE calculated using Deff and Dw was less than 10%. The disparity was higher in head CT SSDE as compared to abdomen CT SSDE, due to lesser correlation between Dw and Deff in head CT scan. Our findings show Deff and Dw to be comparable size metrics for size-specific dose estimate in paediatric CT. The discrepancy between both dose metrics led to slight difference in SSDE calculated using Deff and Dw.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Advancing size-specific dose estimates in CT examinations: Dose estimates at longitudinal positions of scans
    Li, Xinhua
    Marschall, Theodore A.
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2022, 49 (02) : 1303 - 1311
  • [32] Dosimetric comparison of three different cardiac CT angiography techniques in a dual-source scanner using size-specific dose estimation (SSDE)
    Robatjazi, Mostafa
    Alizadeh, Navid Sarmast
    Molazadeh, Mikaeil
    Shokoohy, Fatemeh
    Javadinia, Seyed Alireza
    Dareyni, Amir
    Mosavi, Maryam
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [33] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    Larson, David B.
    PEDIATRIC RADIOLOGY, 2014, 44 : 501 - 505
  • [34] Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
    Zarei F.
    Nasiri M.
    Etemadi Z.
    Haghighi R.R.
    Chatterjee S.
    Khaneghah P.A.
    Chatterjee V.V.
    Iranian Journal of Medical Physics, 2022, 19 (05): : 315 - 321
  • [35] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Boaz Karmazyn
    Huisi Ai
    Paul Klahr
    Fangqian Ouyang
    S. Gregory Jennings
    Pediatric Radiology, 2016, 46 : 1234 - 1240
  • [36] Influence of wide beams of CT scans on size-specific dose estimate (SSDE)
    Abuhaimed, A.
    Martin, C. J.
    Demirkaya, O.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S475 - S476
  • [37] Size-specific dose estimates in pediatric brain CT in relation to age and weight
    Fujii, Kaoru
    Inoue, Yusuke
    Itoh, Hiroyasu
    Sasa, Ryosuke
    Hata, Hirofumi
    Mitsui, Kohei
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (10) : 1075 - 1081
  • [38] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    David B. Larson
    Pediatric Radiology, 2014, 44 : 501 - 505
  • [39] Effect of X-ray spectrum on size-specific dose estimates (SSDEs) for paediatric and adult patients undergoing CT scans
    Abuhaimed, Abdullah
    Martin, Colin J.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 179
  • [40] Improved Estimates of Trunk and Head CT Radiation Dose: Development of Size-Specific Dose Estimate
    Strauss, Keith J.
    McKenney, Sarah E.
    Brady, Samuel L.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (04) : 560 - 562