Main peak interleaved sampling (MPIS) strategy: Effect of stimulation rate variations on speech perception in adult cochlear implant recipients using the Digisonic SP cochlear implant

被引:18
|
作者
Di Lella, Filippo [1 ]
Bacciu, Andrea [1 ]
Pasanisi, Enrico [1 ]
Vincenti, Vincenzo [1 ]
Guida, Maurizio [1 ]
Bacciu, Salvatore [1 ]
机构
[1] Univ Parma, Dept Otolaryngol Head & Neck Surg, Sect Middle Ear Microsurg & Otoneurosurg, I-43100 Parma, Italy
关键词
Cochlear implant; speech coding strategies; main peak interleaved sampling strategy; high rate simulation; ELECTROPHYSIOLOGICAL RESPONSES; ELECTRICAL-STIMULATION; STIMULUS MANIPULATION; SYSTEM; ACE; RECOGNITION;
D O I
10.3109/00016480902896113
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusion: Data obtained from a cohort of 10 post-lingually deaf adult patients indicated that use of a higher stimulation rate, in the setting of the main peak interleaved sampling (MPIS) strategy coupled with the Neurelec-MXM Digisonic SP cochlear implant system, gives a significant advantage in terms of speech perception if compared with a lower rate, especially in a noisy environment. Objectives: To evaluate speech recognition performances in post-lingually deaf adult cochlear implant recipients using two different stimulation rates (260 pps/e and 600 pps/e) in the setting of the MPIS strategy combined with the MXM-Neurelec Digisonic SP cochlear implant system. Patients and methods: Ten post-lingually deaf adults who consecutively received a Neurelec-MXM Digisonic SP device at the Cl Center of the University of Parma participated in the study. The study was conducted prospectively as a within-subject repeated measures (ABA protocol) between January 2007 and January 2008. Each subject was exposed to and sequentially tested with two different rates of stimulation (260 pps/e and 600 pps/e), in quiet and in a noisy environment. Statistical analysis was performed on the data obtained. Results: Subjects using the MPIS strategy with a stimulation rate of 600 pps/e performed significantly better in words and phrases recognition tests in both a noisy and a quiet environment.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 41 条
  • [41] Relationships Between the Auditory Nerve Sensitivity to Amplitude Modulation, Perceptual Amplitude Modulation Rate Discrimination Sensitivity, and Speech Perception Performance in Postlingually Deafened Adult Cochlear Implant Users
    He, Shuman
    Skidmore, Jeffrey
    Koch, Brandon
    Chatterjee, Monita
    Carter, Brittney L.
    Yuan, Yi
    EAR AND HEARING, 2023, 44 (02): : 371 - 384