Main peak interleaved sampling (MPIS) strategy: Effect of stimulation rate variations on speech perception in adult cochlear implant recipients using the Digisonic SP cochlear implant

被引:18
|
作者
Di Lella, Filippo [1 ]
Bacciu, Andrea [1 ]
Pasanisi, Enrico [1 ]
Vincenti, Vincenzo [1 ]
Guida, Maurizio [1 ]
Bacciu, Salvatore [1 ]
机构
[1] Univ Parma, Dept Otolaryngol Head & Neck Surg, Sect Middle Ear Microsurg & Otoneurosurg, I-43100 Parma, Italy
关键词
Cochlear implant; speech coding strategies; main peak interleaved sampling strategy; high rate simulation; ELECTROPHYSIOLOGICAL RESPONSES; ELECTRICAL-STIMULATION; STIMULUS MANIPULATION; SYSTEM; ACE; RECOGNITION;
D O I
10.3109/00016480902896113
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusion: Data obtained from a cohort of 10 post-lingually deaf adult patients indicated that use of a higher stimulation rate, in the setting of the main peak interleaved sampling (MPIS) strategy coupled with the Neurelec-MXM Digisonic SP cochlear implant system, gives a significant advantage in terms of speech perception if compared with a lower rate, especially in a noisy environment. Objectives: To evaluate speech recognition performances in post-lingually deaf adult cochlear implant recipients using two different stimulation rates (260 pps/e and 600 pps/e) in the setting of the MPIS strategy combined with the MXM-Neurelec Digisonic SP cochlear implant system. Patients and methods: Ten post-lingually deaf adults who consecutively received a Neurelec-MXM Digisonic SP device at the Cl Center of the University of Parma participated in the study. The study was conducted prospectively as a within-subject repeated measures (ABA protocol) between January 2007 and January 2008. Each subject was exposed to and sequentially tested with two different rates of stimulation (260 pps/e and 600 pps/e), in quiet and in a noisy environment. Statistical analysis was performed on the data obtained. Results: Subjects using the MPIS strategy with a stimulation rate of 600 pps/e performed significantly better in words and phrases recognition tests in both a noisy and a quiet environment.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 41 条
  • [21] Speech perception results in children using the Clarion® Multi-Strategy™ Cochlear Implant
    Osberger, MJ
    Kalberer, A
    Zimmerman-Phillips, S
    Barker, MJ
    Geier, L
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 75 - 77
  • [22] Effect of reducing electrical stimulation rate on hearing performance of Nucleus® cochlear implant recipients
    Arora, Komal
    Plant, Kerrie
    Dawson, Pam
    Cowan, Robert
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2025, 64 (02) : 173 - 182
  • [23] The Effect of Interdevice Interval on Speech Perception Performance Among Bilateral, Pediatric Cochlear Implant Recipients
    Kocdor, Pelin
    Iseli, Claire E.
    Teagle, Holly F.
    Woodard, Jennifer
    Park, Lisa
    Zdanski, Carlton J.
    Brown, Kevin D.
    Adunka, Oliver F.
    Buchman, Craig A.
    LARYNGOSCOPE, 2016, 126 (10): : 2389 - 2394
  • [24] Speech Perception Performance as a Function of Age at Implantation Among Postlingually Deaf Adult Cochlear Implant Recipients
    Mahmoud, Ahmad F.
    Ruckenstein, Michael J.
    OTOLOGY & NEUROTOLOGY, 2014, 35 (10) : E286 - E291
  • [25] Predicting Postoperative Speech Perception and Audiometric Thresholds Using Intracochlear Electrocochleography in Cochlear Implant Recipients
    Panario, Jared
    Bester, Christofer
    O'Leary, Stephen
    EAR AND HEARING, 2024, 45 (05): : 1173 - 1190
  • [26] Speech perception abilities of adult and pediatric Nucleus implant recipients using the Spectral Peak (SPEAK) coding strategy
    Staller, S
    Menapace, C
    Domico, E
    Mills, D
    Dowell, RC
    Geers, A
    Pijl, S
    Hasenstab, S
    Justus, M
    Brunelli, T
    Adam, A
    Borton, T
    Lemay, M
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (03) : 236 - 242
  • [27] The effect of a coding strategy that removes temporally masked pulses on speech perception by cochlear implant users
    Lamping, Wiebke
    Goehring, Tobias
    Marozeau, Jeremy
    Carlyon, Robert P.
    HEARING RESEARCH, 2020, 391
  • [28] Speech Perception and Localisation with SCORE Bimodal: A Loudness Normalisation Strategy for Combined Cochlear Implant and Hearing Aid Stimulation
    Francart, Tom
    McDermott, Hugh
    PLOS ONE, 2012, 7 (10):
  • [29] Influence of automatic gain control parameter settings on speech understanding of cochlear implant users employing the continuous interleaved sampling strategy
    Stöbich, B
    Zierhofer, CM
    Hochmair, ES
    EAR AND HEARING, 1999, 20 (02): : 104 - 116
  • [30] Melodic Contour Training and Its Effect on Speech in Noise, Consonant Discrimination, and Prosody Perception for Cochlear Implant Recipients
    Lo, Chi Yhun
    McMahon, Catherine M.
    Looi, Valerie
    Thompson, William F.
    BEHAVIOURAL NEUROLOGY, 2015, 2015