High-throughput flow cytometry: Validation in microvolume bioassays

被引:44
|
作者
Ramirez, S [1 ]
Aiken, CT [1 ]
Andrzejewski, B [1 ]
Sklar, LA [1 ]
Edwards, BS [1 ]
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Pathol, Canc Res & Treatment Ctr, Albuquerque, NM 87131 USA
关键词
flow cytometry; automation; drug discovery; biomolecular screening; SELECTIN GLYCOPROTEIN LIGAND-1; P-SELECTIN; DRUG DISCOVERY;
D O I
10.1002/cyto.a.10035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. Methods: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. Results: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. Hyper-Cyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 mul/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Temsaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 X 10(5) to 20 X 10(6) beads/ml) that linearly correlated with manual analysis results. Conclusions: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample thoughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-mul volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods. Cytometry Part A 53A:55-65, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 50 条
  • [41] Flow cytometry for drug discovery, receptor pharmacology and high-throughput screening
    Sklar, Larry A.
    Carter, Mark B.
    Edwards, Bruce S.
    CURRENT OPINION IN PHARMACOLOGY, 2007, 7 (05) : 527 - 534
  • [42] Picophytoplankton identification by flow cytometry and high-throughput sequencing in a clean reservoir
    Ning, Man
    Li, Huimin
    Xu, Zheng
    Chen, Lei
    He, Yiliang
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2021, 216
  • [43] High throughput flow cytometry
    Kuckuck, FW
    Edwards, BS
    Sklar, LA
    CYTOMETRY, 2001, 44 (01): : 83 - 90
  • [44] Performance of in-line microfluidic mixers in laminar flow for high-throughput flow cytometry
    Jackson, WC
    Bennett, TA
    Edwards, BS
    Prossnitz, E
    Lopez, GP
    Sklar, LA
    BIOTECHNIQUES, 2002, 33 (01) : 220 - 226
  • [45] Automated High-Throughput Flow Cytometry for High-Content Screening in Antibody Development
    Wang, Yana
    Yoshihara, Tomoki
    King, Samson
    Tinh Le
    Leroy, Patrick
    Zhao, Xiansi
    Chan, Ching Kit
    Yan, Zhong-Hua
    Menon, Saurabh
    SLAS DISCOVERY, 2018, 23 (07) : 656 - 666
  • [46] A novel high-throughput analytical method to quantify microplastics in water by flow cytometry
    Li, Chaoran
    Campos, Luiza C.
    Busquets, Rosa
    GREEN ANALYTICAL CHEMISTRY, 2023, 5
  • [47] Application of flow cytometry for rapid, high-throughput, multiparametric analysis of environmental microbiomes
    Priyadarsini, Madhumita
    Kushwaha, Jeetesh
    Pandey, Kailash Pati
    Rani, Jyoti
    Dhoble, Abhishek S.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2023, 214
  • [48] Deformability Measurement of Single-Cells at High-Throughput With Imaging Flow Cytometry
    Eluru, Gangadhar
    Srinivasan, Rajesh
    Gorthi, Sai Siva
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2015, 33 (16) : 3475 - 3480
  • [49] Application of High-Throughput Flow Cytometry in Early Drug Discovery: An AstraZeneca Perspective
    Ding, Mei
    Clark, Roger
    Bardelle, Catherine
    Backmark, Anna
    Norris, Tyrrell
    Williams, Wendy
    Wigglesworth, Mark
    Howes, Rob
    SLAS DISCOVERY, 2018, 23 (07) : 719 - 731
  • [50] High-throughput imaging flow cytometry by optofluidic time-stretch microscopy
    Lei, Cheng
    Kobayashi, Hirofumi
    Wu, Yi
    Li, Ming
    Isozaki, Akihiro
    Yasumoto, Atsushi
    Mikami, Hideharu
    Ito, Takuro
    Nitta, Nao
    Sugimura, Takeaki
    Yamada, Makoto
    Yatomi, Yutaka
    Di Carlo, Dino
    Ozeki, Yasuyuki
    Goda, Keisuke
    NATURE PROTOCOLS, 2018, 13 (07) : 1603 - 1631