Determination of talinolol in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry: Application to pharmacokinetic study

被引:6
|
作者
He Juan
Terhaag, Bernd
Yang Li-Ying
Zhang Bi-Kui
Su Fen-Li
Zhu Yun-Gui
Song Juan
Tang Jing
Liu Xiao-Lei
Peng Wen-Xing [1 ]
机构
[1] Cent S Univ, Second Xiangya Hosp, Clin Pharm & Pharmacol Inst, Changsha 410011, Peoples R China
[2] Arzneimittelwerk Dresden GmbH, D-01445 Radebeul, Germany
[3] Hosp Tsing Hua Univ, Dept Pharmaceut, Beijing 100084, Peoples R China
关键词
talinolol; pharmacokinetics; HPLC-MS/ESI;
D O I
10.1016/j.jchromb.2007.03.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive method for determination and screening in human plasma of talinolol is described using propranolol as the internal standard. The analytes in plasma were extracted by liquid-liquid extraction using methyl t-butyl ether. After removed and dried the upper organic phase, the extracts were reconstituted with a fixed volume of buffer of ammonium acetate and acetonitrile (60:40, v/v). The extracts were analyzed by a HPLC coupled to electrospray ionization mass spectrometry (HPLC-MS/ESI). The HPLC separation of the analytes was performed on a Phenomenex C 18 (250 mm x 4.6 mm, 5 mu m, USA) column, with a flow rate of 0.85 mL/mm. The complete elution was obtained within 5.5 min. The calibration curve was linear in the 1.0-400.0 ng/mL range for talinolol, with a coefficient of determination of 0.9996. The average extraction recovery was above 83%. The methodology recovery was between 101% and 102%. The limit of detection (LOD) was 0.3 ng/mL for talinolol. The intraday and inter-day coefficients of variation were less than 6%. This HPLC-MS/ESI procedure was used to assess the pharmacokinetics of talinolol. A single oral 50 mg dose of talinolol tablet was administered to 12 healthy Chinese volunteers, the main pharmacokinetic data are as follows: Cm, was 147.8 +/- 63.8 ng/mL; t(max) was 2.0 +/- 0.7 h; t(1/2) was 12.0 +/- 2.6 h. The method is accurate, sensitive and simple for the pharmacokinetic study of talinolol. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 50 条
  • [41] Quantitation of tamsulosin in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Ding, L
    Li, LM
    Tao, P
    Yang, J
    Zhang, ZX
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01): : 75 - 81
  • [42] Quantification of zolmitriptan in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Zhang, ZJ
    Xu, FG
    Tian, Y
    Li, W
    Mao, GG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 227 - 233
  • [43] Determination of fumonisin in food by high performance liquid chromatography-electrospray ionization tandem mass spectrometry
    Liu, CL
    Xu, WN
    Kofoet, A
    Liu, FM
    Pan, CP
    Xu, YJ
    Jiang, SR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (11) : 1619 - 1622
  • [44] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [45] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [46] Quantitative determination of armodafinil in human plasma by liquid chromatography-electrospray mass spectrometry: Application to a clinical study
    Chandasana, Hardik
    Kast, Johannes
    Bittman, Janina A.
    Derendorf, Hartmut
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (11)
  • [47] Determination of lovastatin in human plasma by ultra-performance liquid chromatography - electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study
    Yuan, Haiyan
    Wang, Feng
    Tu, Jiying
    Peng, Wenxing
    Li, Huande
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) : 808 - 813
  • [48] Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study
    Zhang, Lu
    Tian, Yuan
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2): : 91 - 98
  • [49] Determination of roxatidine in human plasma by liquid chromatography/electrospray mass spectrometry and application to a clinical pharmacokinetic study
    Shin, Beom Soo
    Choi, Jin Won
    Balthasar, Joseph P.
    Hong, Deok Ki
    Kim, Jung Jun
    Yoo, Sun Dong
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (03) : 329 - 335
  • [50] Determination of zaltoprofen in human plasma by liquid chromatography with electrospray tandem mass spectrometry: application to a pharmacokinetic study
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Kim, Yong-Won
    Jeong, Seo-Young
    Lee, Kyung-Tae