Quantitative determination of armodafinil in human plasma by liquid chromatography-electrospray mass spectrometry: Application to a clinical study

被引:3
|
作者
Chandasana, Hardik [1 ]
Kast, Johannes [1 ]
Bittman, Janina A. [1 ]
Derendorf, Hartmut [1 ]
机构
[1] Univ Florida, Dept Pharmaceut, 1345 Ctr Dr,POB 100494, Gainesville, FL 32611 USA
关键词
Ar; modafinil; clinical study; LC-MS/MS; pharmacokinetics; EXCESSIVE SLEEPINESS; MODAFINIL; URINE; VALIDATION; METABOLITE; SINGLE; ACID;
D O I
10.1002/bmc.4342
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Armodafinil is a wake-promoting agent approved in 2007 by the US Food and Drug Administration for the treatment of excessive sleepiness. A rapid, sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of armodafinil in human plasma was developed and validated. Armodafinil and internal standard (armodafinil d-10) were extracted from human plasma using protein precipitation combined with liquid-liquid extraction. This developed method only requires 50 mu L of plasma for the analysis. The chromatographic separation was performed with a Waters symmetry, C-18, 4.6 x 150 mm, 5 mu m column using formic acid, water and acetonitrile as solvent delivered at a 0.7 mL/min flow rate. The total run time of the method was 3 min. The method was validated according to regulatory guidance in terms of specificity, selectivity, linearity, matrix effect, recovery and stability. Optimized Q1/Q3 mass transitions for armodafinil and armodafinil d-10 were 274.1/167.2 (m/z) and 284.4/177.4 (m/z) respectively. The method showed linearity within the tested concentration range of 10-10,000 ng/mL. The method was successfully applied to quantify armodafinil concentrations after single oral administration of a 250 mg tablet in a clinical study conducted in healthy volunteers. Significant advantages of this method are minimal sample volume, short run time and a lower LLOQ.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantitative determination of rocuronium in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Farenc, C
    Enjalbal, C
    Sanchez, P
    Bressolle, F
    Audran, M
    Martinez, J
    Aubagnac, JL
    JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) : 61 - 67
  • [2] Determination of penciclovir in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study
    Kanneti, Ravi
    Bhavesh, Dasandi
    Paramar, Dharmesh
    Shivaprakash, R.
    Bhatt, Parloop A.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (04) : 458 - 465
  • [3] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [4] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [5] Quantitative determination of capsaicinoids by liquid chromatography-electrospray mass spectrometry
    Thompson, RQ
    Phinney, KW
    Welch, MJ
    White, VE
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (07) : 1441 - 1451
  • [6] Determination of dimenhydrinate in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a relative bioavailability study
    Tavares, V.
    Macedo, C. C.
    Montanhez, L.
    Barros, F. A. P.
    Meurer, E. C.
    Campos, D. R.
    Coelho, E. C.
    Calaffati, S. A.
    Pedrazzoli, J., Jr.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 127 - 132
  • [8] Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study
    Chen, Lingyun
    Qin, Feng
    Ma, Yuanyuan
    Li, Famei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 255 - 261
  • [9] Determination of berberine in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Hua, Wenyan
    Ding, Li
    Chen, Yan
    Gong, Bin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 931 - 937
  • [10] Determination of talinolol in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry: Application to pharmacokinetic study
    He Juan
    Terhaag, Bernd
    Yang Li-Ying
    Zhang Bi-Kui
    Su Fen-Li
    Zhu Yun-Gui
    Song Juan
    Tang Jing
    Liu Xiao-Lei
    Peng Wen-Xing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 275 - 280