Determination of talinolol in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry: Application to pharmacokinetic study

被引:6
|
作者
He Juan
Terhaag, Bernd
Yang Li-Ying
Zhang Bi-Kui
Su Fen-Li
Zhu Yun-Gui
Song Juan
Tang Jing
Liu Xiao-Lei
Peng Wen-Xing [1 ]
机构
[1] Cent S Univ, Second Xiangya Hosp, Clin Pharm & Pharmacol Inst, Changsha 410011, Peoples R China
[2] Arzneimittelwerk Dresden GmbH, D-01445 Radebeul, Germany
[3] Hosp Tsing Hua Univ, Dept Pharmaceut, Beijing 100084, Peoples R China
关键词
talinolol; pharmacokinetics; HPLC-MS/ESI;
D O I
10.1016/j.jchromb.2007.03.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive method for determination and screening in human plasma of talinolol is described using propranolol as the internal standard. The analytes in plasma were extracted by liquid-liquid extraction using methyl t-butyl ether. After removed and dried the upper organic phase, the extracts were reconstituted with a fixed volume of buffer of ammonium acetate and acetonitrile (60:40, v/v). The extracts were analyzed by a HPLC coupled to electrospray ionization mass spectrometry (HPLC-MS/ESI). The HPLC separation of the analytes was performed on a Phenomenex C 18 (250 mm x 4.6 mm, 5 mu m, USA) column, with a flow rate of 0.85 mL/mm. The complete elution was obtained within 5.5 min. The calibration curve was linear in the 1.0-400.0 ng/mL range for talinolol, with a coefficient of determination of 0.9996. The average extraction recovery was above 83%. The methodology recovery was between 101% and 102%. The limit of detection (LOD) was 0.3 ng/mL for talinolol. The intraday and inter-day coefficients of variation were less than 6%. This HPLC-MS/ESI procedure was used to assess the pharmacokinetics of talinolol. A single oral 50 mg dose of talinolol tablet was administered to 12 healthy Chinese volunteers, the main pharmacokinetic data are as follows: Cm, was 147.8 +/- 63.8 ng/mL; t(max) was 2.0 +/- 0.7 h; t(1/2) was 12.0 +/- 2.6 h. The method is accurate, sensitive and simple for the pharmacokinetic study of talinolol. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 50 条
  • [1] Determination and pharmacokinetic study of amlodipine in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry
    Ma, Yuanyuan
    Qin, Feng
    Sun, Xiaohong
    Lu, Xiumei
    Li, Famei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1540 - 1545
  • [2] Determination of isotretinoin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Wu, Lili
    Wu, Jingjing
    Zhou, Ke
    Cheng, Fang
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (02) : 324 - 329
  • [3] Determination of enalapril in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Yoon, KH
    Kim, W
    Park, J
    Kim, HJ
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (06): : 878 - 880
  • [4] Determination of cyclobenzaprine in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study
    Xiang, Yi
    Zhou, Liping
    Qian, Zhenyu
    Peng, Kelong
    Li, Dongyan
    Chen, Xiaomei
    Jiang, Hongliang
    Zheng, Heng
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (09) : 1083 - 1088
  • [5] Determination of penciclovir in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study
    Kanneti, Ravi
    Bhavesh, Dasandi
    Paramar, Dharmesh
    Shivaprakash, R.
    Bhatt, Parloop A.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (04) : 458 - 465
  • [6] Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study
    Chen, Lingyun
    Qin, Feng
    Ma, Yuanyuan
    Li, Famei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 255 - 261
  • [7] Determination of vinflunine in rat plasma by liquid chromatography-electrospray ionization mass spectrometry for a pharmacokinetic study
    Zhao, Xiaoping
    Liu, Xiaoquan
    Wang, Yongsheng
    Zhong, Jiao
    Chen, Yan
    Wang, Guangji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 906 - 911
  • [8] Determination of lafutidine in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry: application to a bioequivalence study
    Wu, LL
    Zhang, ZJ
    Tian, Y
    Li, W
    Xu, FG
    Chen, Y
    Wei, HL
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12): : 1637 - 1643
  • [9] Determination of apomorphine in canine plasma by liquid chromatography-electrospray ionization mass spectrometry and its application to pharmacokinetic study
    Yang, Bei
    Yu, Yunqiu
    Cai, Lei
    Deng, Chunhui
    Duan, Gengli
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (14) : 2173 - 2178
  • [10] Determination of raltitrexed in human plasma by high performance liquid chromatography-electrospray ionization-mass spectrometry
    Hu, Jingjing
    Ding, Li
    Song, Qinxin
    Gao, Ying
    Qing, Shukui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 147 - 153