Evaluation of the Accuracy of Digital Impressions Obtained from Intraoral and Extraoral Dental Scanners with Different CAD/CAM Scanning Technologies: An In Vitro Study

被引:21
|
作者
Ellakany, Passent [1 ]
El Tantawi, Maha [2 ]
Mahrous, Amr A. [1 ]
Al-Harbi, Fahad [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Substitut Dent Sci, POBox 1982, Dammam, Saudi Arabia
[2] Alexandria Univ, Fac Dent, Dept Pediat Dent & Dent Publ Hlth, Alexandria, Egypt
关键词
Computer-aided design; computer-aided manufacturing (CAD; CAM); intraoral scanner; extraoral scanner; digital impression; conventional impression; CONVENTIONAL IMPRESSIONS; PREPARED TEETH; REPRODUCIBILITY;
D O I
10.1111/jopr.13400
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the accuracy of intraoral and extraoral scanners (IOSs and EOSs) with different scanning technologies. Material and Methods A phantom cast was used to simulate the patient's mouth. Polyether impression was made of the phantom cast and poured to fabricate stone casts. The stone casts were scanned by two IOSs (3shape Trios 3, 3S and Dental Wings, DW) and two EOSs (S600 Arti Zirkonzahn, ZK and Ceramill map 600 Amann Girrbach, AG) to obtain digital casts. Reference teeth (canines, premolar, and molars) dimensions were measured on the digital casts by Geomagic software and compared to measurements of the stone cast done by stereomicroscope. The dimensions were occluso-cervical mesio-distal, and bucco-lingual and their average was calculated. Differences between digital and stereoscopic measurements were assessed using paired t-test. Discrepancies between these measurements were calculated as differences and were compared among the four scanners using ANOVA. Results The differences among the discrepancies of the four scanners were not significant overall (p = 0.969), in premolars (p = 0.932) or molars (p = 0.069) but significant in canines (p = 0.025). The discrepancies of the EOSs were <= 0.01 mm in canines and molars. DW had the greatest discrepancy in canines and molars. Conclusions The IOSs and EOSs had similar accuracy except in canines where EOSs performed better. The accuracy of scanning is affected by the smoothness and regularity of the teeth surfaces as in case of the canine.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 50 条
  • [41] Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards
    Jeon, Jin-Hun
    Hwang, Seong-Sig
    Kim, Ji-Hwan
    Kim, Woong-Chul
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (05): : 335 - 339
  • [42] The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
  • [43] Evaluation of the accuracy of 2 digital intraoral scanners: A 3D analysis study
    Alzahrani, Saeed J.
    EL-Hammali, Hind
    Morgano, Steven M.
    Elkassaby, Heba
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06): : 787 - 792
  • [44] Accuracy of 3-dimensional printed dental models reconstructed from digital intraoral impressions
    Brown, Gregory B.
    Currier, G. Frans
    Kadioglu, Onur
    Kierl, J. Peter
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 154 (05) : 733 - 739
  • [45] Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study
    Motel, Constantin
    Kirchner, Elena
    Adler, Werner
    Wichmann, Manfred
    Matta, Ragai Edward
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 309 - 314
  • [46] Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners
    Revilla-Leon, Marta
    Jiang, Peng
    Sadeghpour, Mehrad
    Piedra-Cascon, Wenceslao
    Zandinejad, Amirali
    Oezcan, Mutlu
    Krishnamurthy, Vinayak R.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03): : 372 - 378
  • [47] The role of artificial intelligence in intraoral scanning for complete-arch digital impressions: An in vitro study
    Roth, Ivett
    Geczi, Zoltan
    Vegh, Daniel Csaba
    Hegedus, Tamas
    Pal, Adrienn
    Hermann, Peter
    Schmalzl, Judit
    JOURNAL OF DENTISTRY, 2025, 156
  • [48] Evaluation of the accuracy of direct intraoral scanner impressions for digital post and core in various post lengths: An in-vitro study
    Almalki, A.
    Conejo, J.
    Kutkut, N.
    Blatz, M.
    Hai, Q.
    Anadioti, E.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (04) : 673 - 679
  • [49] Measurement of Tooth Wear by Means of Digital Impressions: An In-Vitro Evaluation of Three Intraoral Scanning Systems
    Kuehne, Christina
    Lohbauer, Ulrich
    Raith, Stefan
    Reich, Sven
    APPLIED SCIENCES-BASEL, 2021, 11 (11):
  • [50] Three-Dimensional Scanning Accuracy of Intraoral Scanners for Dental Implant Scan Bodies-An Original Study
    Rotaru, Cristian
    Bica, Elena Adina
    Butnarasu, Cristian
    Sandulescu, Mihai
    MEDICINA-LITHUANIA, 2023, 59 (11):