Evaluation of the Accuracy of Digital Impressions Obtained from Intraoral and Extraoral Dental Scanners with Different CAD/CAM Scanning Technologies: An In Vitro Study

被引:21
|
作者
Ellakany, Passent [1 ]
El Tantawi, Maha [2 ]
Mahrous, Amr A. [1 ]
Al-Harbi, Fahad [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Substitut Dent Sci, POBox 1982, Dammam, Saudi Arabia
[2] Alexandria Univ, Fac Dent, Dept Pediat Dent & Dent Publ Hlth, Alexandria, Egypt
关键词
Computer-aided design; computer-aided manufacturing (CAD; CAM); intraoral scanner; extraoral scanner; digital impression; conventional impression; CONVENTIONAL IMPRESSIONS; PREPARED TEETH; REPRODUCIBILITY;
D O I
10.1111/jopr.13400
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the accuracy of intraoral and extraoral scanners (IOSs and EOSs) with different scanning technologies. Material and Methods A phantom cast was used to simulate the patient's mouth. Polyether impression was made of the phantom cast and poured to fabricate stone casts. The stone casts were scanned by two IOSs (3shape Trios 3, 3S and Dental Wings, DW) and two EOSs (S600 Arti Zirkonzahn, ZK and Ceramill map 600 Amann Girrbach, AG) to obtain digital casts. Reference teeth (canines, premolar, and molars) dimensions were measured on the digital casts by Geomagic software and compared to measurements of the stone cast done by stereomicroscope. The dimensions were occluso-cervical mesio-distal, and bucco-lingual and their average was calculated. Differences between digital and stereoscopic measurements were assessed using paired t-test. Discrepancies between these measurements were calculated as differences and were compared among the four scanners using ANOVA. Results The differences among the discrepancies of the four scanners were not significant overall (p = 0.969), in premolars (p = 0.932) or molars (p = 0.069) but significant in canines (p = 0.025). The discrepancies of the EOSs were <= 0.01 mm in canines and molars. DW had the greatest discrepancy in canines and molars. Conclusions The IOSs and EOSs had similar accuracy except in canines where EOSs performed better. The accuracy of scanning is affected by the smoothness and regularity of the teeth surfaces as in case of the canine.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 50 条
  • [21] Performance and perception of dental students using three intraoral CAD/CAM scanners for full-arch scanning
    Ahmed, Khaled E.
    Wang, Ting
    Li, Kar Yan
    Luk, Wai Kuen
    Burrow, Michael F.
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (02) : 167 - 172
  • [22] In vitro Evaluation of Accuracy of Single Dies Captured by Two Intraoral Digital Scanners
    Burde, Alexandru Victor
    Gasparik, Cristina
    Moldovan, Marioara
    Baciu, Sorana
    Cosma, Cosmin
    MATERIALE PLASTICE, 2018, 55 (02) : 176 - 178
  • [23] Clinical Evaluation of CAD/CAM Metal-Ceramic Posterior Crowns Fabricated from Intraoral Digital Impressions
    Tamim, Hazem
    Skjerven, Henrik
    Ekfeldt, Anders
    Ronold, Hans Jacob
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (04) : 331 - 337
  • [24] Accuracy of various intraoral scanners in scanning post space preparation: An in vitro study
    Abouseif, Abanoub M.
    Abdelkader, Sanaa H.
    Abdelraheem, Islam M.
    JOURNAL OF DENTISTRY, 2025, 155
  • [25] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64
  • [26] Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies
    Hardan, Louis
    Bourgi, Rim
    Lukomska-Szymanska, Monika
    Hernandez-Cabanillas, Juan Carlos
    Zamarripa-Calderon, Juan Eliezer
    Jorquera, Gilbert
    Ghishan, Sinan
    Cuevas-Suarez, Carlos Enrique
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (06): : 315 - 332
  • [27] Clinical evaluation of the accuracy of two face scanners with different scanning technologies
    Srinivasan, Murali
    Leles, Claudio Rodrigues
    Berisha, Florentin
    Bronzino, Innocenzo
    Milhomens, Yasmin
    Kim, Sung-Jin
    Park, Koungjin
    Lee, Jae-Hyun
    JOURNAL OF DENTISTRY, 2025, 153
  • [28] Scanning accuracy and scanning area discrepancies of intraoral digital scans acquired at varying scanning distances and angulations among 4 different intraoral scanners
    Button, Heather
    Kois, John C.
    Barmak, Abdul B.
    Zeitler, Jonathan M.
    Rutkunas, Vygandas
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 1044 - 1060
  • [29] Accuracy of digital impressions of multiple dental implants: an in vitro study
    Vandeweghe, Stefan
    Vervack, Valentin
    Dierens, Melissa
    De Bruyn, Hugo
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (06) : 648 - 653
  • [30] Accuracy of digital implant impressions obtained using intraoral scanners: a systematic review and meta-analysis of in vivo studies
    Ma, Jie
    Zhang, Binghua
    Song, Hao
    Wu, Dongle
    Song, Tao
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)