The interaction between applied peep and auto-peep during one-lung ventilation

被引:39
|
作者
Slinger, PD
Hickey, DR
机构
[1] Univ Toronto, Toronto Hosp, Dept Anaesthesia, Toronto, ON M5G 2C4, Canada
[2] McGill Univ, Montreal Gen Hosp, Dept Anaesthesia, Montreal, PQ H3G 1A4, Canada
关键词
thoracic anesthesia; positive end-expiratory pressure; thoracic surgery; one-lung ventilation;
D O I
10.1016/S1053-0770(98)90318-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate the relationship between applied external positive end-expiratory pressure (PEEP) and auto-PEEP and the resultant total PEEP experienced by the patient during one-lung ventilation (OLV). Design: A prospective clinical study. Setting: A university hospital. Participants: Ten adult patients undergoing elective thoracotomies. Interventions: End-expiratory airway occlusion and measurement of plateau pressure during two-lung ventilation (TLV) and OLV with and without the application of 5 cm H2O of external PEEP via the anesthetic ventilator. The effect of variation of the inspiratory-expiratory ratio on total PEEP with and without applied external PEEP was also studied. Main Results: The mean level (+/-SD) of auto-PEEP changing from two-lung to one-lung ventilation rose from 0.9 (+/-0.8) cm H2O to 6.0 (+/-3.0) cm H2O at an inspiratory-expiratory ratio of 1:2. The application of 5 cm H2O external PEEP did not increase the total PEEP (7.3 +/- 2.0 cm H2O) significantly. The total PEEP increased significantly when the duration of expiration was decreased, and decreased when expiratory time increased. The change in total PEEP caused by the application of external PEEP during OLV correlated inversely with the preexisting level of auto-PEEP (r = -0.84). Conclusion: The change in end-expiratory pressure experienced by the ventilated lung during OLV when external PEEP is applied depends on the preexisting level of auto-PEEP. This may explain some of the inconsistencies in the clinical results of application of external PEEP during OLV. The total PEEP delivered to the patient should be measured whenever external PEEP is applied during OLV. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:133 / 136
页数:4
相关论文
共 50 条
  • [31] AUTO-PEEP DURING CPR - AN OCCULT CAUSE OF ELECTROMECHANICAL DISSOCIATION
    ROGERS, PL
    SCHLICHTIG, R
    MIRO, A
    PINSKY, M
    CHEST, 1991, 99 (02) : 492 - 493
  • [32] Auto-PEEP to Treat Obstructive Sleep Apnea
    White, David P.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2009, 5 (06): : 538 - 539
  • [33] Occult, occult auto-PEEP in status asthmaticus
    Stewart, TE
    Slutsky, AS
    CRITICAL CARE MEDICINE, 1996, 24 (03) : 379 - 380
  • [34] AUTO-PEEP CONTRIBUTING TO FAILED APNEA TEST
    Burr, Andrew
    Denny, John
    Pantin, Enrique
    Hylton, Andre
    Denny, Angela
    Ginsberg, Steven
    Hunter, Chris
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U321 - U321
  • [35] It's Time to Reappraise the Impact of Auto-PEEP
    Ku, Shih-Chi
    RESPIRATORY CARE, 2016, 61 (02) : 258 - 259
  • [36] AUTO-PEEP - INCIDENCE, MAGNITUDE, AND CONTRIBUTING FACTORS
    WRIGHT, J
    GONG, H
    HEART & LUNG, 1990, 19 (04): : 352 - 357
  • [37] Effects of tidal volume and PEEP on arterial blood gases and pulmonary mechanics during one-lung ventilation
    Sang Hun Kim
    Ki Tae Jung
    Tae Hun An
    Journal of Anesthesia, 2012, 26 : 568 - 573
  • [38] Effects of tidal volume and PEEP on arterial blood gases and pulmonary mechanics during one-lung ventilation
    Kim, Sang Hun
    Jung, Ki Tae
    An, Tae Hun
    JOURNAL OF ANESTHESIA, 2012, 26 (04) : 568 - 573
  • [39] Effect of external PEEP in patients under controlled mechanical ventilation with an auto-PEEP of 5 cmH2O or higher
    Natalini, Giuseppe
    Tuzzo, Daniele
    Rosano, Antonio
    Testa, Marco
    Grazioli, Michele
    Pennestri, Vincenzo
    Amodeo, Guido
    Berruto, Francesco
    Fiorillo, Marialinda
    Peratoner, Alberto
    Tinnirello, Andrea
    Filippini, Matteo
    Marsilia, Paolo F.
    Minelli, Cosetta
    Bernardini, Achille
    ANNALS OF INTENSIVE CARE, 2016, 6
  • [40] AUTO-PEEP AND DYNAMIC HYPERINFLATION IN COPD PATIENTS DURING CONTROLLED MECHANICAL VENTILATION AND HIGH-FREQUENCY JET VENTILATION
    CONTI, G
    BUFI, M
    ROCCO, M
    CALZECCHI, E
    DEBLASI, RA
    ANTONELLI, M
    PELAIA, P
    GASPARETTO, A
    INTENSIVE CARE MEDICINE, 1990, 16 (02) : 81 - 84