AUTO-PEEP AND DYNAMIC HYPERINFLATION IN COPD PATIENTS DURING CONTROLLED MECHANICAL VENTILATION AND HIGH-FREQUENCY JET VENTILATION

被引:10
|
作者
CONTI, G
BUFI, M
ROCCO, M
CALZECCHI, E
DEBLASI, RA
ANTONELLI, M
PELAIA, P
GASPARETTO, A
机构
[1] Istituto di Anestesia e Rianimazione, Università 'La Sapienza', Rome
关键词
Auto-PEEP; COPD; High frequency jet ventilation;
D O I
10.1007/BF02575298
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We investigated the levels of auto-PEEP and dynamic hyperinflation during high frequency jet ventilation (HFJV) and controlled mechanical ventilation (CMV) in six patients with chronic obstructive pulmonary disease within the first 36 h of acute exacerbation. The comparative evaluation was performed at similar conditions of gas exchange in HFJV and CMV: PaO2 77.6±11 mmHg vs 80.8±12 mmHg; PaCO2 46.8±2.5 mmHg vs 47±2.8 mmHg; pH 7.38 vs 7.38. In this situation, the values of auto-PEEP and dynamic hyperinflation, expressed as Δ over the apneic functional residual capacity (FRC) did not differ: (auto-PEEPHFJV 8.9±3.8 cmH2O; auto-PEEPCMV 8.8±4.7 cmH2O; ΔFRCHFJV 0.56±0.19 l; ΔFRCCMV 0.54±0.2 l). This result suggests that, with a suitable machine setting and similar gas exchanges, HFJV produces the same level of auto-PEEP and dynamic hyperinflation as CMV in patients with chronic obstructive pulmonary disease. © 1990 Springer-Verlag.
引用
收藏
页码:81 / 84
页数:4
相关论文
共 50 条
  • [1] AUTO-PEEP, HIGH-FREQUENCY JET VENTILATION
    HWANG, NC
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (03) : 430 - 430
  • [2] HIGH-FREQUENCY JET VENTILATION PRODUCES AUTO-PEEP
    BEAMER, WC
    PROUGH, DS
    ROYSTER, RL
    JOHNSTON, WE
    JOHNSON, JC
    CRITICAL CARE MEDICINE, 1984, 12 (09) : 734 - 737
  • [3] VOLUME-CONTROLLED INVERSE RATIO VENTILATION - EFFECT ON DYNAMIC HYPERINFLATION AND AUTO-PEEP
    VALTA, P
    TAKALA, J
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (04) : 323 - 328
  • [4] DYNAMIC HYPERINFLATION AND INTRINSIC PEEP DURING MECHANICAL VENTILATION
    ROMAND, JA
    SUTER, PM
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1994, 11 (01) : 25 - 28
  • [5] DOES MEASURED AUTO-PEEP (AP) ACCURATELY REFLECT THE DEGREE OF DYNAMIC HYPERINFLATION (DH) DURING MECHANICAL VENTILATION (MV) OF STATUS ASTHMA (SA)
    LEATHERMAN, JW
    RAVENSCRAFT, SA
    IBER, C
    DAVIES, S
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A877 - A877
  • [6] DETERMINANTS OF VENTILATION DURING HIGH-FREQUENCY JET VENTILATION
    GUNTUPALLI, KK
    PINSKY, MR
    MARQUEZ, J
    KRUGER, K
    GANDHI, A
    KLAIN, MM
    JOURNAL OF CRITICAL CARE, 1987, 2 (02) : 93 - 100
  • [7] Intrinsic (or auto-) PEEP during controlled mechanical ventilation
    Brochard, L
    INTENSIVE CARE MEDICINE, 2002, 28 (10) : 1376 - 1378
  • [8] Intrinsic (or auto-) PEEP during controlled mechanical ventilation
    Laurent Brochard
    Intensive Care Medicine, 2002, 28 : 1376 - 1378
  • [9] Effect of external PEEP in patients under controlled mechanical ventilation with an auto-PEEP of 5 cmH2O or higher
    Natalini, Giuseppe
    Tuzzo, Daniele
    Rosano, Antonio
    Testa, Marco
    Grazioli, Michele
    Pennestri, Vincenzo
    Amodeo, Guido
    Berruto, Francesco
    Fiorillo, Marialinda
    Peratoner, Alberto
    Tinnirello, Andrea
    Filippini, Matteo
    Marsilia, Paolo F.
    Minelli, Cosetta
    Bernardini, Achille
    ANNALS OF INTENSIVE CARE, 2016, 6
  • [10] Effect of external PEEP in patients under controlled mechanical ventilation with an auto-PEEP of 5 cmH2O or higher
    Giuseppe Natalini
    Daniele Tuzzo
    Antonio Rosano
    Marco Testa
    Michele Grazioli
    Vincenzo Pennestrì
    Guido Amodeo
    Francesco Berruto
    Marialinda Fiorillo
    Alberto Peratoner
    Andrea Tinnirello
    Matteo Filippini
    Paolo F. Marsilia
    Cosetta Minelli
    Achille Bernardini
    Annals of Intensive Care, 6