Long-term Assessment of Tilt of Glued Intraocular Lenses An Optical Coherence Tomography Analysis 5 Years after Surgery

被引:34
|
作者
Kumar, Dhivya Ashok [1 ]
Agarwal, Amar [1 ]
Agarwal, Athiya [1 ]
Chandrasekar, Radika [1 ]
Priyanka, Vijetha [1 ]
机构
[1] Dr Agarwals Eye Hosp & Eye Res Ctr, Madras 600086, Tamil Nadu, India
关键词
ULTRASOUND BIOMICROSCOPY; INTRASCLERAL FIXATION; ASTIGMATISM ANALYSIS; CAPSULAR SUPPORT; CATARACT-SURGERY; ANTERIOR-CHAMBER; VISUAL OUTCOMES; FIBRIN SEALANT; IMPLANTATION; EYES;
D O I
10.1016/j.ophtha.2014.07.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Long-term assessment of the optic position of glued transscleral fixated intraocular lens (IOL) with optical coherence tomography (OCT). Design: Prospective observational case series. Participants: Patients with a minimum 5 years' follow-up after glued IOL surgery were included. Methods: Postoperatively, IOL position was examined by anterior segment OCT (Carl Zeiss Meditec) and the scans were analyzed in 2 axes (180 degrees-0 degrees and 270 degrees-90 degrees) using MatLab (Mathworks). Best-corrected visual acuity (BCVA; Snellen's charts), Orbscan, retinoscopy, refraction, and slit-lamp biomicroscopy were performed. Main Outcome Measures: The distance between the iris margin and the anterior IOL optic (D1, D2), slope of the line across the iris and IOL, the slope ratio between the IOL and iris, IOL tilt, and optic surface changes were determined and correlated with the astigmatism and vision. Results: A total of 60 eyes (mean follow-up of 5.9 +/- 0.2 years; range, 5-6 years) were evaluated. There was a significant correlation (P = 0.000) between the slope of iris and the IOL in horizontal and vertical axes. The mean D1 and D2 were 0.94 +/- 0.36 and 0.95 +/- 0.36 mm, respectively. Nine of 60 eyes (15%) had pigment dispersed on the IOL surface. Twenty-one eyes (35%) had optic tilt detected on OCT and 65% of eyes had no optic tilt. The mean angle between the IOL and the iris was noted to be 3.2 +/- 2.7 degrees and 2.9 +/- 2.6 degrees in horizontal and vertical axes, respectively. The mean ocular residual astigmatism (ORA) was 0.53 +/- 0.5 diopters. There was no difference in the ORA between the eyes with and without tilt (P = 0.762). There was no correlation (P = 0.348) between the ORA and BCVA. Position of the IOL was not dependent on the type of lens, age of the patient, or the preoperative surgical indication. Conclusions: Long-term analysis with OCT demonstrated good IOL positioning without any significant optic tilt in patients with glued IOL fixation. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [41] Long-Term Changes in the Coronary Artery Structure After Heart Transplantation: A Prospective Optical Coherence Tomography Study
    Bjerre, K. P.
    Clemmensen, T. S.
    Poulsen, S.
    Christiansen, E.
    Neghabat, O.
    Holm, N.
    Hvas, A.
    Grove, E. L.
    Kristensen, S. D.
    Eiskjaer, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S127 - S127
  • [42] Fully Automated Biometry of In Situ Intraocular Lenses Using Long Scan Depth Spectral-Domain Optical Coherence Tomography
    Chen, Qi
    Leng, Lin
    Zhu, Dexi
    Wang, Yaozeng
    Shao, Yilei
    Wang, Jianhua
    Lu, Fan
    Shen, Meixiao
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (01): : 37 - 45
  • [43] Assessment of macular profile using optical coherence tomography after epiretinal membrane surgery
    Mazit, C.
    Scholtes, F.
    Rabaut, C.
    Jallet, G.
    Cochereau, I.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (07): : 667 - 672
  • [44] Chronic Total Occlusion 5 Years After Bioresorbable Vascular Scaffold Implantation: A Serial Optical Coherence Tomography Assessment
    Ochijewicz, Dorota
    Tomaniak, Mariusz
    Koltowski, Lukasz
    Kochman, Janusz
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (05): : E141 - E141
  • [45] Analysis of the macula with optical coherence tomography after successful surgery for proliferative vitreoretinopathy
    Benson, SE
    Grigoropoulos, V
    Schlottmann, PG
    Bunce, C
    Charteris, DG
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) : 1651 - 1656
  • [46] Optical coherence tomography analysis of the macula after vitrectomy surgery for retinal detachment
    Benson, SE
    Schlottmann, PG
    Bunce, C
    Xing, W
    Charteris, DG
    OPHTHALMOLOGY, 2006, 113 (07) : 1179 - 1183
  • [47] Long-term repeatability of peripapillary optical coherence tomography angiography measurements in healthy eyes
    Lee, Woo Hyuk
    Lee, Min-Woo
    Kim, Min-Su
    Ryu, Cheon Kuk
    Kim, Jung-Yeul
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Long-term repeatability of peripapillary optical coherence tomography angiography measurements in healthy eyes
    Woo Hyuk Lee
    Min-Woo Lee
    Min-Su Kim
    Cheon Kuk Ryu
    Jung-Yeul Kim
    Scientific Reports, 11
  • [49] Long-term reproducibility of optical coherence tomography angiography in healthy and stable glaucomatous eyes
    Nishida, Takashi
    Moghimi, Sasan
    Hou, Huiyuan
    Proudfoot, James A.
    Chang, Aimee C.
    David, Ryan Caezar C.
    Kamalipour, Alireza
    El-Nimri, Nevin
    Rezapour, Jasmin
    Bowd, Christopher
    Zangwill, Linda M.
    Weinreb, Robert N.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (05) : 657 - 662
  • [50] Optical coherence tomography changes in ankylosing spondylitis patients on long-term adalimumab treatment
    Yavuz, Nurce Cilesizoglu
    Ozer, Murat Atabey
    Sari, Ilker Fatih
    Kulakli, Sevgi
    Tatli, Samet
    Ogut, Halil
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2022, 68 (12): : 1626 - 1630