Long-term Assessment of Tilt of Glued Intraocular Lenses An Optical Coherence Tomography Analysis 5 Years after Surgery

被引:34
|
作者
Kumar, Dhivya Ashok [1 ]
Agarwal, Amar [1 ]
Agarwal, Athiya [1 ]
Chandrasekar, Radika [1 ]
Priyanka, Vijetha [1 ]
机构
[1] Dr Agarwals Eye Hosp & Eye Res Ctr, Madras 600086, Tamil Nadu, India
关键词
ULTRASOUND BIOMICROSCOPY; INTRASCLERAL FIXATION; ASTIGMATISM ANALYSIS; CAPSULAR SUPPORT; CATARACT-SURGERY; ANTERIOR-CHAMBER; VISUAL OUTCOMES; FIBRIN SEALANT; IMPLANTATION; EYES;
D O I
10.1016/j.ophtha.2014.07.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Long-term assessment of the optic position of glued transscleral fixated intraocular lens (IOL) with optical coherence tomography (OCT). Design: Prospective observational case series. Participants: Patients with a minimum 5 years' follow-up after glued IOL surgery were included. Methods: Postoperatively, IOL position was examined by anterior segment OCT (Carl Zeiss Meditec) and the scans were analyzed in 2 axes (180 degrees-0 degrees and 270 degrees-90 degrees) using MatLab (Mathworks). Best-corrected visual acuity (BCVA; Snellen's charts), Orbscan, retinoscopy, refraction, and slit-lamp biomicroscopy were performed. Main Outcome Measures: The distance between the iris margin and the anterior IOL optic (D1, D2), slope of the line across the iris and IOL, the slope ratio between the IOL and iris, IOL tilt, and optic surface changes were determined and correlated with the astigmatism and vision. Results: A total of 60 eyes (mean follow-up of 5.9 +/- 0.2 years; range, 5-6 years) were evaluated. There was a significant correlation (P = 0.000) between the slope of iris and the IOL in horizontal and vertical axes. The mean D1 and D2 were 0.94 +/- 0.36 and 0.95 +/- 0.36 mm, respectively. Nine of 60 eyes (15%) had pigment dispersed on the IOL surface. Twenty-one eyes (35%) had optic tilt detected on OCT and 65% of eyes had no optic tilt. The mean angle between the IOL and the iris was noted to be 3.2 +/- 2.7 degrees and 2.9 +/- 2.6 degrees in horizontal and vertical axes, respectively. The mean ocular residual astigmatism (ORA) was 0.53 +/- 0.5 diopters. There was no difference in the ORA between the eyes with and without tilt (P = 0.762). There was no correlation (P = 0.348) between the ORA and BCVA. Position of the IOL was not dependent on the type of lens, age of the patient, or the preoperative surgical indication. Conclusions: Long-term analysis with OCT demonstrated good IOL positioning without any significant optic tilt in patients with glued IOL fixation. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [21] Assessment of long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery
    Michael Burgmüller
    Kata Mihaltz
    Christopher Schütze
    Bernhard Angermann
    Veronika Vécsei-Marlovits
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2018, 256 : 2361 - 2367
  • [22] Prognostic Utility of Optical Coherence Tomography for Long-Term Visual Recovery Following Pituitary Tumor Surgery
    Wang, Michael T. M.
    King, James
    Symons, R. C. Andrew
    Stylli, Stanley S.
    Meyer, Joos
    Daniell, Mark D.
    Savino, Peter J.
    Kaye, Andrew H.
    Danesh-Meyer, Helen, V
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 247 - 254
  • [23] Analysis of Intraocular Lens Biofilms and Fluids After Long-Term Uncomplicated Cataract Surgery
    Mazoteras, Paloma
    Quiles, Milene Goncalves
    Martins Bispo, Paulo Jose
    Hofling-Lima, Ana Luisa
    Pignatari, Antonio C.
    Casaroli-Marano, Ricardo P.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 46 - 57
  • [24] Anatomical optical coherence tomography for long-term, portable, quantitative endoscopy
    Leigh, Matthew S.
    Armstrong, Julian J.
    Paduch, Alexandre
    Walsh, Jennifer H.
    Hillman, David R.
    Eastwood, Peter R.
    Sampson, David D.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (04) : 1438 - 1446
  • [25] LONG-TERM STABILITY OF INTRAOCULAR LENSES - LITERATURE-REVIEW, ASSESSMENT, AND TESTING PROTOCOL
    BRUCK, SD
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1993, 3 (04) : 333 - 350
  • [26] Tilt and decentration of posterior and anterior iris-claw intraocular lenses: a pilot study using anterior segment optical coherence tomography
    Giacomo Calzetti
    Carlo Bellucci
    Salvatore Antonio Tedesco
    Maurizio Rossi
    Stefano Gandolfi
    Paolo Mora
    BMC Ophthalmology, 22
  • [27] Tilt and decentration of posterior and anterior iris-claw intraocular lenses: a pilot study using anterior segment optical coherence tomography
    Calzetti, Giacomo
    Bellucci, Carlo
    Tedesco, Salvatore Antonio
    Rossi, Maurizio
    Gandolfi, Stefano
    Mora, Paolo
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [28] Long-Term Follow-Up of Macular Perfusion Evaluated by Optical Coherence Tomography Angiography after Rhegmatogenous Retinal Detachment Surgery
    Bartolome-Sese, Isabel
    Diaz-Barreda, Maria D.
    Orduna-Hospital, Elvira
    Boned-Murillo, Ana
    Ascaso, Francisco J.
    Pinilla, Isabel
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (22)
  • [29] Long-Term Visual Acuity and Optical Coherence Tomography Changes After Vitrectomy for Idiopathic Epiretinal Membranes
    Abu -Ain, Mohammad
    Shatnawi, Raed
    Shehadeh, Ibrahim
    Khan, Mohammad Irfan
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 693 - 700
  • [30] Long-Term Results after Intraocular Surgery in Treated Retinoblastoma Eyes
    Rating, Philipp
    Bornfeld, Norbert
    Schlueter, Sabrina
    Westekemper, Henrike
    Kiefer, Tobias
    Stuschke, Martin
    Goericke, Sophia
    Ketteler, Petra
    Ting, Saskia
    Metz, Klaus A.
    Bechrakis, Nikolaos E.
    Biewald, Eva
    OCULAR ONCOLOGY AND PATHOLOGY, 2022, 8 (03) : 161 - 167