Development of implantable real time micro dosimeter system

被引:0
|
作者
Yamada, Shogo [1 ]
Nakata, Eiko [2 ]
Momose, Genki [3 ]
Kikuchi, Youhei [3 ]
Ogawa, Yoshihiro [1 ]
Mori, Issei [2 ]
Oishi, Mikio [2 ]
Ishii, Keizo [3 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Radiat Oncol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9810872, Japan
[2] Tohoku Univ, Sch Med, Dept Hlth Sci, Sendai, Miyagi, Japan
[3] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Sendai, Miyagi, Japan
关键词
radiation therapy; cancer; micro dosimeter; CdTe semiconductor; magnetic field; real time;
D O I
10.1142/9781860948800_0029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although progress of radiation therapy in recent years is rapid, medical accidents like the irradiation of over and under dose occur frequently in Japan. To eradicate these accidents and to increase accuracy of radiation therapy, we are developing an implantable real time micro dosimeter system. CdTe semiconductor is used as an ideal detector. And the doses of radiation are monitored by measuring the magnetic field converted from the current. We investigated the relationship between dose rate and current value from CdTe semiconductor(4mmx4mmx0.5mm). The data showed that 70 to 90 nA of electric current is proportionally generated from the CdTe semiconductor when it is irradiated by a LINAC under an air condition by the dose rate of I similar to 6Gy/min. In addition, the proportion of irradiated dose and the current was confirmed under a subaqueous condition(15cm in depth). To investigate the influence of a magnetic, field on a human body, we calculated the tolerance frequency for human body using FEM simulation method. The data showed that the sending and receiving of data as a frequency of magnetic field should be set 100MHz or less. We are now miniaturizing the dosimeter circuit up to the size of inserted level by a fine needle.
引用
收藏
页码:271 / +
页数:3
相关论文
共 50 条
  • [1] Preliminary evaluation of wireless communication system for implantable real time radiation dosimeter system
    Momose, Genki
    Ishii, Keizo
    Yamada, Shogo
    Nakata, Eiko
    FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 795 - +
  • [2] Development of a water equivalent multichannel real time dosimeter
    Bartesaghi, G.
    Bolognini, D.
    Mascagna, V.
    Prest, M.
    Scazzi, S.
    Conti, V.
    Mozzanica, A.
    Monti, A. F.
    Ostinelli, A.
    Frigerio, M.
    Gelosa, S.
    Cappelletti, P.
    Giannini, G.
    Vallazza, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S112 - S112
  • [3] Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry
    Volotskova, O.
    Jenkins, C.
    Fahimian, B.
    Xing, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3649 - 3650
  • [4] Development of a Real-Time Gamma Dosimeter of High Sensitivity
    Sharma, S. L.
    Maity, T. K.
    Kumar, G. Anil
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 341 - +
  • [5] The Development of a Real-Time Image Guided Micro Electroplating System
    Chen, Ting-Chao
    Hwang, Yean-Ren
    Lin, Jing-Chie
    Ciou, Yong-Jie
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (12): : 1810 - 1820
  • [6] An analysis of an implantable dosimeter system for external beam therapy
    Black, RD
    Scarantino, CW
    Mann, GG
    Anscher, MS
    Ornitz, RD
    Nelms, BE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01): : 290 - 300
  • [7] Implantable radiation dosimeter
    Mann, G
    Lehman, P
    McSoley, B
    Rini, C
    Widener, S
    Scarantino, C
    Black, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1436 - 1436
  • [8] An implantable radiation dosimeter
    Scarantino, C
    Mann, G
    Ornitz, R
    Anscher, M
    Carrea, T
    Rini, C
    Widener, S
    Black, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1837 - 1837
  • [9] Implantable radiation dosimeter
    Black, R
    Mann, G
    Lehman, P
    McSoley, B
    Rini, C
    Widener, S
    Scarantino, C
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S11 - S11
  • [10] DEVELOPMENT OF REAL-TIME PERSONAL NEUTRON DOSIMETER WITH 2 SILICON DETECTORS
    NAKAMURA, T
    TSUJIMURA, N
    YAMANO, T
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 469 - 470