Optical-Flow-Based B-Mode Elastography: Application in the Hypertensive Rat Carotid

被引:32
|
作者
Zakaria, Toufik [1 ,4 ]
Qin, Zhao [1 ]
Maurice, Roch Listz [1 ,2 ,3 ]
机构
[1] Ctr Hosp Univ Montreal, Lab Biorheol & Med Ultrason, Ctr Rech, Montreal, PQ H3C 3P8, Canada
[2] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[4] Arts & Metiers Paris Tech, F-75014 Paris, France
基金
加拿大自然科学与工程研究理事会;
关键词
B-mode elastography; carotid artery; engineered rat models; hypertension; optical flow equations; small animal imaging; strain tensor; INTRAVASCULAR ULTRASOUND ELASTOGRAPHY; NONINVASIVE VASCULAR ELASTOGRAPHY; IN-VIVO; PLAQUE COMPONENTS; CATHETER POSITION; MOTION ESTIMATION; BLOOD-PRESSURE; STRAIN; SYSTEM; ELASTICITY;
D O I
10.1109/TMI.2009.2038694
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background-Ultrasound elastography is now used worldwide in tissue characterization. The primary premises of elastography are that speckle kinematics reproduces underlying tissue kinematics and that tissue motion can be inferred from speckle tracking. This implicitly assumes that speckle pattern is a material property that can be tracked with respect to time and space. It is then convenient to express the motion of such a material property in terms of total derivative, also known as optical flow (OF) equations. Aims-The present paper introduces a new iterative OF-based elastography (OFBE) method devoted to B-mode data. The first OFBE iteration computes axial and lateral displacement fields. Such displacement fields are used for data rigid registration, prior to the second OFBE iteration which computes the 2-D strain tensor. Methods-The OFBE method was validated in the common carotid artery of rat hypertension models. The effect of aging on carotid stiffness was investigated in female recombinant inbred rats (RI-17, (n = 2) in the first experiment. The outcomes of low/high-salt diets were examined in young male Dahl salt-sensitive rats (SS, n = 6; SM12, n = 6; SM9, n = 6) in the second experiment. Results-Good concordance was observed between left and right carotid axial strain measurements with 11.4% relative error, whereas 4.6% relative error occurred between diastolic and systolic axial strain measurements. Old (80 and 85 weeks) RI-17 carotids were determined to be twice as stiff with 5.70 +/- 0.97% (strain +/- std) as young carotids (30 and 34 weeks) with 13.26 +/- 2.73%, p < 0.001. Carotid axial strain measurement also indicated that salt diets had a significant impact on SS (p = 0.008) and SM12 (p < 0.001) but not on SM9 (p = 0.881) rats.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [41] ULTRASOUND AND CT REGISTRATION QUALITY: ELASTOGRAPHY VS. CLASSICAL B-MODE
    Keil, Matthias
    Stolka, Philipp J.
    Wiebel, Marion
    Sakas, Georgios
    McVeigh, Elliot R.
    Taylor, Russell H.
    Boctor, Emad
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 967 - +
  • [42] Automatic Prostate Segmentation Using Fused Ultrasound B-Mode and Elastography Images
    Mahdavi, S. Sara
    Moradi, Mehdi
    Morris, William J.
    Salcudean, Septimiu E.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 76 - +
  • [43] DEEP LEARNING-BASED CAROTID PLAQUE SEGMENTATION FROM B-MODE ULTRASOUND IMAGES
    Zhou, Ran
    Azarpazhooh, M. Reza
    Spence, J. David
    Hashemi, Samineh
    Ma, Wei
    Cheng, Xinyao
    Gan, Haitao
    Ding, Mingyue
    Fenster, Aaron
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09): : 2723 - 2733
  • [44] Carotid Artery B-Mode Ultrasound Image Segmentation based on Morphology, Geometry and Gradient Direction
    Sunarya, I. Made Gede
    Yuniarno, Eko Mulyanto
    Purnomo, Mauridhi Hery
    Sardjono, Tri Arief
    Sunu, Ismoyo
    Purnama, I. Ketut Eddy
    SECOND INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION, 2017, 10443
  • [45] Deep learning based on carotid transverse B-mode scan videos for the diagnosis of carotid plaque: a prospective multicenter study
    Jia Liu
    Xinrui Zhou
    Hui Lin
    Xue Lu
    Jian Zheng
    Erjiao Xu
    Dianhu Jiang
    Hui Zhang
    Xin Yang
    Junlin Zhong
    Xindi Hu
    Yuhao Huang
    Yanling Zhang
    Jiamin Liang
    Qin Liu
    Min Zhong
    Yuansen Chen
    Huixiang Yan
    Haowen Deng
    Rongqin Zheng
    Dong Ni
    Jie Ren
    European Radiology, 2023, 33 : 3478 - 3487
  • [46] Ultrasonography of vulnerable atherosclerotic plaque in the carotid arteries: B-mode imaging
    Fedak, Andrzej
    Ciuk, Katarzyna
    Urbanik, Andrzej
    JOURNAL OF ULTRASONOGRAPHY, 2020, 20 (81) : E135 - E145
  • [47] NONLINEAR PROCESSING IN B-MODE ULTRASOUND AFFECTS CAROTID DIAMETER ASSESSMENT
    Rossi, Alessandro C.
    Brands, Peter J.
    Hoeks, Arnold P. G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (05): : 736 - 747
  • [48] B-MODE SONOGRAPHY FINDINGS IN THE CAROTID BIFURCATION OF HEMODIALYSIS-PATIENTS
    NEVELING, M
    HOJER, C
    BEWERMEYER, H
    MERTENS, M
    ULTRASCHALL IN DER MEDIZIN, 1992, 13 (03): : 127 - 131
  • [49] Automatic segmentation of carotid B-mode images using fuzzy classification
    Rocha, Rui
    Silva, Jorge
    Campilho, Aurelio
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (05) : 533 - 545
  • [50] Estimation of carotid diameter with heartbeat on longitudinal B-mode ultrasonic images
    Kawamura, Y.
    Yokota, Y.
    Nogata, F.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3142 - +