Optical-Flow-Based B-Mode Elastography: Application in the Hypertensive Rat Carotid

被引:32
|
作者
Zakaria, Toufik [1 ,4 ]
Qin, Zhao [1 ]
Maurice, Roch Listz [1 ,2 ,3 ]
机构
[1] Ctr Hosp Univ Montreal, Lab Biorheol & Med Ultrason, Ctr Rech, Montreal, PQ H3C 3P8, Canada
[2] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[4] Arts & Metiers Paris Tech, F-75014 Paris, France
基金
加拿大自然科学与工程研究理事会;
关键词
B-mode elastography; carotid artery; engineered rat models; hypertension; optical flow equations; small animal imaging; strain tensor; INTRAVASCULAR ULTRASOUND ELASTOGRAPHY; NONINVASIVE VASCULAR ELASTOGRAPHY; IN-VIVO; PLAQUE COMPONENTS; CATHETER POSITION; MOTION ESTIMATION; BLOOD-PRESSURE; STRAIN; SYSTEM; ELASTICITY;
D O I
10.1109/TMI.2009.2038694
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background-Ultrasound elastography is now used worldwide in tissue characterization. The primary premises of elastography are that speckle kinematics reproduces underlying tissue kinematics and that tissue motion can be inferred from speckle tracking. This implicitly assumes that speckle pattern is a material property that can be tracked with respect to time and space. It is then convenient to express the motion of such a material property in terms of total derivative, also known as optical flow (OF) equations. Aims-The present paper introduces a new iterative OF-based elastography (OFBE) method devoted to B-mode data. The first OFBE iteration computes axial and lateral displacement fields. Such displacement fields are used for data rigid registration, prior to the second OFBE iteration which computes the 2-D strain tensor. Methods-The OFBE method was validated in the common carotid artery of rat hypertension models. The effect of aging on carotid stiffness was investigated in female recombinant inbred rats (RI-17, (n = 2) in the first experiment. The outcomes of low/high-salt diets were examined in young male Dahl salt-sensitive rats (SS, n = 6; SM12, n = 6; SM9, n = 6) in the second experiment. Results-Good concordance was observed between left and right carotid axial strain measurements with 11.4% relative error, whereas 4.6% relative error occurred between diastolic and systolic axial strain measurements. Old (80 and 85 weeks) RI-17 carotids were determined to be twice as stiff with 5.70 +/- 0.97% (strain +/- std) as young carotids (30 and 34 weeks) with 13.26 +/- 2.73%, p < 0.001. Carotid axial strain measurement also indicated that salt diets had a significant impact on SS (p = 0.008) and SM12 (p < 0.001) but not on SM9 (p = 0.881) rats.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [21] The subpixel resolution of optical-flow-based modal analysis
    Javh, Jaka
    Slavic, Janko
    Boltezar, Miha
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2017, 88 : 89 - 99
  • [22] Method for Optical-Flow-Based Precision Missile Guidance
    Manchester, Ian R.
    Savkin, Andrey V.
    Faruqi, Farhan A.
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2008, 44 (03) : 835 - 851
  • [23] Application of shear wave elastography and B-mode ultrasound in patellar tendinopathy after extracorporeal shockwave therapy
    Zhang, Cici
    Duan, Lixia
    Liu, Qiong
    Zhang, Wen
    JOURNAL OF MEDICAL ULTRASONICS, 2020, 47 (03) : 469 - 476
  • [24] Application of shear wave elastography and B-mode ultrasound in patellar tendinopathy after extracorporeal shockwave therapy
    Cici Zhang
    Lixia Duan
    Qiong Liu
    Wen Zhang
    Journal of Medical Ultrasonics, 2020, 47 : 469 - 476
  • [25] Application and evaluation of novel optical-flow-based motion correction algorithms to breast MRI
    Botella, Guillermo
    Baese, Anke Meyer
    Baese, Uwe Meyer
    EVOLUTIONARY AND BIO-INSPIRED COMPUTATION: THEORY AND APPLICATIONS IV, 2010, 7704
  • [26] Correlates of mammographic density in B-mode ultrasound and real time elastography
    Jud, Sebastian Michael
    Haeberle, Lothar
    Fasching, Peter A.
    Heusinger, Katharina
    Hack, Carolin
    Faschingbauer, Florian
    Uder, Michael
    Wittenberg, Thomas
    Wagner, Florian
    Meier-Meitinger, Martina
    Schulz-Wendtland, Ruediger
    Beckmann, Matthias W.
    Adamietz, Boris R.
    EUROPEAN JOURNAL OF CANCER PREVENTION, 2012, 21 (04) : 343 - 349
  • [27] Synthetic Elastography from B-Mode ultrasound through Deep Learning
    Wildeboer, R. R.
    van Sloun, R. J. G.
    Mannaerts, Christophe K.
    Salomon, G.
    Wijkstra, H.
    Mischi, M.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 108 - 110
  • [28] Quantitative breast mass classification based on the integration of B-mode features and strain features in elastography
    Lo, Chung-Ming
    Chang, Yeun-Chung
    Yang, Ya-Wen
    Huang, Chiun-Sheng
    Chang, Ruey-Feng
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 64 : 91 - 100
  • [29] Computer-Aided Diagnosis of Breast Elastography and B-Mode Ultrasound
    Selvan, Shirley
    Shenbagadevi, S.
    Suresh, S.
    ARTIFICIAL INTELLIGENCE AND EVOLUTIONARY ALGORITHMS IN ENGINEERING SYSTEMS, VOL 2, 2015, 325 : 213 - 223
  • [30] Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound
    Pons, Gerard
    Marti, Joan
    Marti, Robert
    Ganau, Sergi
    Noble, J. Alison
    ULTRASONIC IMAGING, 2016, 38 (03) : 209 - 224