Optical-Flow-Based B-Mode Elastography: Application in the Hypertensive Rat Carotid

被引:32
|
作者
Zakaria, Toufik [1 ,4 ]
Qin, Zhao [1 ]
Maurice, Roch Listz [1 ,2 ,3 ]
机构
[1] Ctr Hosp Univ Montreal, Lab Biorheol & Med Ultrason, Ctr Rech, Montreal, PQ H3C 3P8, Canada
[2] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[4] Arts & Metiers Paris Tech, F-75014 Paris, France
基金
加拿大自然科学与工程研究理事会;
关键词
B-mode elastography; carotid artery; engineered rat models; hypertension; optical flow equations; small animal imaging; strain tensor; INTRAVASCULAR ULTRASOUND ELASTOGRAPHY; NONINVASIVE VASCULAR ELASTOGRAPHY; IN-VIVO; PLAQUE COMPONENTS; CATHETER POSITION; MOTION ESTIMATION; BLOOD-PRESSURE; STRAIN; SYSTEM; ELASTICITY;
D O I
10.1109/TMI.2009.2038694
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background-Ultrasound elastography is now used worldwide in tissue characterization. The primary premises of elastography are that speckle kinematics reproduces underlying tissue kinematics and that tissue motion can be inferred from speckle tracking. This implicitly assumes that speckle pattern is a material property that can be tracked with respect to time and space. It is then convenient to express the motion of such a material property in terms of total derivative, also known as optical flow (OF) equations. Aims-The present paper introduces a new iterative OF-based elastography (OFBE) method devoted to B-mode data. The first OFBE iteration computes axial and lateral displacement fields. Such displacement fields are used for data rigid registration, prior to the second OFBE iteration which computes the 2-D strain tensor. Methods-The OFBE method was validated in the common carotid artery of rat hypertension models. The effect of aging on carotid stiffness was investigated in female recombinant inbred rats (RI-17, (n = 2) in the first experiment. The outcomes of low/high-salt diets were examined in young male Dahl salt-sensitive rats (SS, n = 6; SM12, n = 6; SM9, n = 6) in the second experiment. Results-Good concordance was observed between left and right carotid axial strain measurements with 11.4% relative error, whereas 4.6% relative error occurred between diastolic and systolic axial strain measurements. Old (80 and 85 weeks) RI-17 carotids were determined to be twice as stiff with 5.70 +/- 0.97% (strain +/- std) as young carotids (30 and 34 weeks) with 13.26 +/- 2.73%, p < 0.001. Carotid axial strain measurement also indicated that salt diets had a significant impact on SS (p = 0.008) and SM12 (p < 0.001) but not on SM9 (p = 0.881) rats.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [1] Optical Flow-based B-Mode Elastography: Application in the Hypertensive Rat Carotid
    Maurice, Roch L.
    Qin, Zhao
    Peng, Junzheng
    Dahdah, Nagib
    Tremblay, Johanne
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 708 - 712
  • [2] B-mode flow imaging of the carotid artery
    Umemura, A
    Yamada, K
    STROKE, 2001, 32 (09) : 2055 - 2057
  • [3] Role of assessment of carotid atherosclerosis by B-mode ultrasonography in treatment of hypertensive patients
    Hougaku, Hidetaka
    Kitagawa, Kazuo
    Yamagami, Hiroshi
    Imoto, Hiroyuki Hash
    Itch, Taiji
    Shimizu, Yoshiomi
    Takahashis, Daisuke
    Kondo, Kimito
    Sakaguchi, Manabu
    Hori, Masatsugu
    JOURNAL OF HYPERTENSION, 2006, 24 : 196 - 196
  • [4] B-Flow and B-Mode Ultrasound Imaging in Carotid Fibromuscular Dysplasia
    Cutler, Joshua J.
    Campo, Nelly
    Koch, Sebastian
    JOURNAL OF NEUROIMAGING, 2018, 28 (03) : 269 - 272
  • [5] Application of Demons Algorithm in Ultrasound Elastography using B-Mode Ultrasound Images
    Tehrani, Ali Kafaei Zad
    Mozaffarzadeh, Moein
    Mardi, Zahra
    Hozhabr, Seyed Hani
    Mehrmohammadi, Mohammad
    Makkiabadi, Bahador
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2019, 2019, 10878
  • [6] B-MODE SONOGRAPHY OF CAROTID ARTERIES
    TOLLY, E
    DIETRICH, G
    SCHREYER, H
    RADIOLOGE, 1983, 23 (04): : 179 - 184
  • [7] B-MODE SONOGRAPHY OF THE CAROTID BIFURCATION
    TERWEY, B
    GAHBAUER, H
    MONTEMAYOR, M
    PROUSSALIS, A
    ZOLLNER, G
    ULTRASCHALL IN DER MEDIZIN, 1984, 5 (05): : 190 - 201
  • [8] Application of intraoperative B-mode ultrasound and shear wave elastography for glioma grading
    Yin, Lu
    Cheng, Linggang
    Wang, Fumin
    Zhu, Xueli
    Hua, Yue
    He, Wen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (06) : 2733 - 2743
  • [9] Blood flow generation in B-MODE ultrasound images of the carotid artery
    Hamou, AK
    El-Sakka, MR
    ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 2945 - 2948
  • [10] Quantitative breast elastography from B-mode images
    Rabin, Carolina
    Benech, Nicolas
    MEDICAL PHYSICS, 2019, 46 (07) : 3001 - 3012