Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study

被引:116
|
作者
Allain, J [1 ]
Roudot-Thoraval, F [1 ]
Delecrin, J [1 ]
Anract, P [1 ]
Migaud, H [1 ]
Goutallier, D [1 ]
机构
[1] Hop Henri Mondor, Serv Chirurg Orthoped, F-94010 Creteil, France
来源
关键词
D O I
10.2106/00004623-200305000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The alumina ceramic femoral head was introduced for total hip arthroplasty approximately thirty years ago. One of its main drawbacks was the risk of implant fracture. The aim of this study was to examine the results of revision total hip replacement performed specifically to treat a fracture of a ceramic femoral head and to identify technical factors that affected the outcomes. Methods: One hundred and five surgical revisions to treat a fracture of a ceramic femoral head, performed at thirty-five institutions, were studied. The patients were examined clinically by the operating surgeon at the time of the last follow-up. The surgeon provided the latest follow-up radiographs, which were compared with the immediate postoperative radiographs. The success of the revisions was assessed with Kaplan-Meier survivorship analysis, with the need for repeat revision as the end point. We evaluated the complication rate and radiographic changes indicative of implant loosening. The average duration of follow-up between the index revision and the last clinical and radiographic review was 3.5 years (range, six months to twenty years). Results: Following the revisions, radiographic evidence of cup loosening was seen in twenty-two hips (21%) and radiographic evidence of femoral loosening was seen in twenty-two (21%). One or several repeat revisions were necessary in thirty-three patients (31%) because of infection (four patients), implant loosening (twenty), osteolysis (eight), or fracture of the revision femoral head component (one). The survival rate at five years was 63% (95% confidence interval, 51% to 75%). The survival rate was significantly worse when the cup had not been changed, when the new femoral head was made of stainless steel, when a total synovectomy had not been done, and when the patient was less than fifty years old. Conclusions: Fracture of a ceramic femoral head component is a rare but potentially serious event. A suitable surgical approach, including total synovectomy, cup exchange, and insertion of a cobalt-chromium or new ceramic femoral ball minimizes the chance of early loosening of the implants and the need for one or more repeat revisions. Level of Evidence: Therapeutic study, Level I (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:825 / 830
页数:6
相关论文
共 50 条
  • [41] Fracture of the precoated femoral component after cemented total hip arthroplasty
    Yamasaki, Satoshi
    Masuhara, Kensaku
    Fuji, Takeshi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (03) : 308 - 311
  • [42] Inferior outcome after intraoperative femoral fracture in total hip arthroplasty
    Thillemann, Theis M.
    Pedersen, Alma B.
    Johnsen, Soren P.
    Soballe, Kjeld
    ACTA ORTHOPAEDICA, 2008, 79 (03) : 327 - 334
  • [43] An evaluation of bone loss after total hip arthroplasty for femoral head necrosis after femoral neck fracture -: A quantitative CT study in 16 patients
    Neander, G
    von Sivers, K
    Adolphson, P
    Dahlborn, M
    Dalén, N
    JOURNAL OF ARTHROPLASTY, 1999, 14 (01): : 64 - 70
  • [44] Revision Total Hip Arthroplasty With Modular Femoral Stems
    Stimac, Jeffrey D.
    Boles, John
    Parkes, Natalie
    Della Valle, Alejandro Gonzalez
    Boettner, Friedrich
    Westrich, Geoffrey H.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2167 - 2170
  • [45] Total Hip Arthroplasty After Failed Treatment for Osteonecrosis of the Femoral Head
    Rijnen, Wim H. C.
    Lameijn, Nanette
    Schreurs, B. Willem
    Gardeniers, Jean W. M.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (02) : 291 - +
  • [46] Assessing the pattern of femoral head penetration after total hip arthroplasty
    Hopper, RH
    Young, AM
    Engh, CA
    McAuley, JP
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 22 - 29
  • [47] Modular Femoral Stems for Revision Total Hip Arthroplasty
    Restrepo, Camilo
    Mashadi, Magdalena
    Parvizi, Javad
    Austin, Matthew S.
    Hozack, William J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 476 - 482
  • [48] FEMORAL WINDOWS IN REVISION TOTAL HIP-ARTHROPLASTY
    KLEIN, AH
    RUBASH, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (291) : 164 - 170
  • [49] The influence of cemented femoral stem choice on the incidence of revision for periprosthetic fracture after primary total hip arthroplasty
    Palan, J.
    Smith, M. C.
    Gregg, P.
    Mellon, S.
    Kulkarni, A.
    Tucker, K.
    Blom, A. W.
    Murray, D. W.
    Pandit, H.
    BONE & JOINT JOURNAL, 2016, 98B (10): : 1347 - 1354
  • [50] Revision total hip arthroplasty with cemented femoral component
    Nouri, Habib
    Kallel, Sofiene
    Slimane, Mohamed Hadj
    Meherzi, Mohamed Hedi
    Ouertatani, Moez
    Karray, Salahedine
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (05): : 327 - 332