Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study

被引:116
|
作者
Allain, J [1 ]
Roudot-Thoraval, F [1 ]
Delecrin, J [1 ]
Anract, P [1 ]
Migaud, H [1 ]
Goutallier, D [1 ]
机构
[1] Hop Henri Mondor, Serv Chirurg Orthoped, F-94010 Creteil, France
来源
关键词
D O I
10.2106/00004623-200305000-00009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The alumina ceramic femoral head was introduced for total hip arthroplasty approximately thirty years ago. One of its main drawbacks was the risk of implant fracture. The aim of this study was to examine the results of revision total hip replacement performed specifically to treat a fracture of a ceramic femoral head and to identify technical factors that affected the outcomes. Methods: One hundred and five surgical revisions to treat a fracture of a ceramic femoral head, performed at thirty-five institutions, were studied. The patients were examined clinically by the operating surgeon at the time of the last follow-up. The surgeon provided the latest follow-up radiographs, which were compared with the immediate postoperative radiographs. The success of the revisions was assessed with Kaplan-Meier survivorship analysis, with the need for repeat revision as the end point. We evaluated the complication rate and radiographic changes indicative of implant loosening. The average duration of follow-up between the index revision and the last clinical and radiographic review was 3.5 years (range, six months to twenty years). Results: Following the revisions, radiographic evidence of cup loosening was seen in twenty-two hips (21%) and radiographic evidence of femoral loosening was seen in twenty-two (21%). One or several repeat revisions were necessary in thirty-three patients (31%) because of infection (four patients), implant loosening (twenty), osteolysis (eight), or fracture of the revision femoral head component (one). The survival rate at five years was 63% (95% confidence interval, 51% to 75%). The survival rate was significantly worse when the cup had not been changed, when the new femoral head was made of stainless steel, when a total synovectomy had not been done, and when the patient was less than fifty years old. Conclusions: Fracture of a ceramic femoral head component is a rare but potentially serious event. A suitable surgical approach, including total synovectomy, cup exchange, and insertion of a cobalt-chromium or new ceramic femoral ball minimizes the chance of early loosening of the implants and the need for one or more repeat revisions. Level of Evidence: Therapeutic study, Level I (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:825 / 830
页数:6
相关论文
共 50 条
  • [31] Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty
    Hummer, CD
    Rothman, RH
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06): : 848 - 850
  • [32] Subtrochanteric femoral shortening osteotomy concomitantly performed with revision total hip arthroplasty A case report
    Takeda, Yu
    Fukunishi, Shigeo
    Nishio, Shoji
    Fujihara, Yuki
    Yoshiya, Shinichi
    MEDICINE, 2018, 97 (42)
  • [33] Outcomes of Hybrid Total Hip Arthroplasty for Subchondral Insufficiency Fracture of the Femoral Head
    Kweon, Suc-Hyun
    Park, Jin Sung
    Baek, Seung Jeong
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (03) : 390 - 396
  • [34] What is the Survivorship of Fully Coated Femoral Components in Revision Hip Arthroplasty?
    Lachiewicz, Paul F.
    Soileau, Elizabeth S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) : 549 - 554
  • [35] Risk Factors for Early Conversion Total Hip Arthroplasty After Pipkin IV Femoral Head Fracture
    Cichos, Kyle H.
    White, Parker A.
    Bergin, Patrick F.
    Ghanem, Elie S.
    McGwin, Gerald
    Hawkins, Jacob
    Spitler, Clay A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (04) : 181 - 188
  • [36] Revision Total Hip Arthroplasty with a Modular Fluted Tapered Stem for a Periprosthetic Femoral Fracture
    Hannon, Charles P. P.
    Abdel, Matthew P. P.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (03):
  • [37] SIZE OF THE FEMORAL-HEAD AND ACETABULAR REVISION IN TOTAL HIP-REPLACEMENT ARTHROPLASTY
    MORREY, BF
    ILSTRUP, D
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01): : 50 - 55
  • [38] Complications and Survivorship After Aseptic Revision Total Hip Arthroplasty: Is There a Difference by Surgical Approach?
    Mccormick, Kyle L.
    Mastroianni, Michael A.
    Kolodychuk, Nicholas L.
    Herndon, Carl L.
    Shah, Roshan P.
    Cooper, H. John
    Sarpong, Nana O.
    JOURNAL OF ARTHROPLASTY, 2025, 40 (01): : 203 - 207
  • [39] Midterm Survivorship After Revision Total Hip Arthroplasty With a Custom Triflange Acetabular Component
    Gladnick, Brian P.
    Fehring, Keith A.
    Odum, Susan M.
    Christie, Michael J.
    DeBoer, David K.
    Fehring, Thomas K.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 500 - 504
  • [40] Nonunion after periprosthetic femoral fracture associated with total hip arthroplasty
    Crockarell, JR
    Berry, DJ
    Lewallen, DG
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (08): : 1073 - 1079