Preliminary comparison of inductively coupled plasma mass spectrometry and electrospray mass spectrometry hyphenated with ion chromatography for trace analysis of iodide

被引:14
|
作者
Buchberger, W
Czizsek, B
Hann, S
Stingeder, G
机构
[1] Johannes Kepler Univ Linz, Dept Analyt Chem, A-4040 Linz, Austria
[2] Univ Agr Sci, Inst Chem, A-1190 Vienna, Austria
关键词
D O I
10.1039/b301442h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-exchange chromatography hyphenated with mass spectrometric detection has been investigated for the determination of iodide in urine. Satisfactory chromatographic behavior of iodide could be achieved on a hydrophilic polymer-based anion-exchange column with 35 mM sodium hydroxide as the mobile phase. When electrospray ionization (ESI) was used, a suppressor as well as a flow splitter (split ratio 1:10) was required between the column and the interface. In the case of an inductively coupled plasma (ICP) ionization source, eluent and flow-rate were completely compatible with the interface. Under comparable chromatographic conditions, the ESI interface yielded a detection limit of 15 mug L-1 (quadrupole instrument), whereas the ICP interface lowered the detection limits by approximately two (quadrupole instrument) and three (sector field instrument) orders of magnitude. For urine samples both methods gave virtually the same results except for the relative standard deviation, which was 7% for ESI and 0.55% for sector field ICP. The molecule-selective detection of ESI may be an advantage in cases when insufficient separation from other iodine-containing species cannot be avoided. The element-selective ICP will be the preferred tool when iodide has to be determined in the sub-ppb range.
引用
收藏
页码:512 / 514
页数:3
相关论文
共 50 条
  • [41] Determination of Chromium Species using Ion Chromatography coupled to Inductively Coupled Plasma Mass Spectrometry
    Schmelzel, John
    Kutscher, Daniel
    Fisher, Carl
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 11 (43):
  • [42] ENVIRONMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Beauchemin, Diane
    MASS SPECTROMETRY REVIEWS, 2010, 29 (04) : 560 - 592
  • [43] Inductively coupled plasma mass spectrometry analysis of wines
    Pérez-Jordán, MY
    Soldevila, J
    Salvador, A
    Pastor, A
    de la Guardia, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) : 33 - 39
  • [44] Water analysis by inductively coupled plasma mass spectrometry
    V. K. Karandashev
    A. Yu. Leikin
    V. A. Khvostikov
    N. K. Kutseva
    S. V. Pirogova
    Inorganic Materials, 2016, 52 : 1391 - 1404
  • [45] Determination of trimethylselenonium ion in urine by ion chromatography and inductively coupled plasma mass spectrometry detection
    Gammelgaard, B
    Jessen, KD
    Kristensen, FH
    Jons, O
    ANALYTICA CHIMICA ACTA, 2000, 404 (01) : 47 - 54
  • [46] Water analysis by inductively coupled plasma mass spectrometry
    Karandashev, V. K.
    Leikin, A. Yu
    Khvostikov, V. A.
    Kutseva, N. K.
    Pirogova, S. V.
    INORGANIC MATERIALS, 2016, 52 (14) : 1391 - 1404
  • [47] Characterization of spent nuclear fuels by ion chromatography inductively coupled plasma mass spectrometry
    Moreno, JMB
    Alonso, JIG
    Arbore, P
    Nicolaou, G
    Koch, L
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (10) : 929 - 935
  • [48] Simultaneous determination of arsenic species by ion chromatography inductively coupled plasma mass spectrometry
    Terasahde, P
    PantsarKallio, M
    Manninen, PKG
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 83 - 88
  • [49] ANALYSES OF IMPURITIES IN METHAMPHETAMINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ION CHROMATOGRAPHY
    SUZUKI, S
    TSUCHIHASHI, H
    NAKAJIMA, K
    MATSUSHITA, A
    NAGAO, T
    JOURNAL OF CHROMATOGRAPHY, 1988, 437 (01): : 322 - 327
  • [50] SPECIATION OF SELENIUM IN BIOLOGICAL SAMPLES BY ION CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Wang, Weihong
    Chen, ZuLiang
    Davey, David Edward
    Naidu, Ravendra
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2010, 33 (9-12) : 1151 - 1173