Preliminary comparison of inductively coupled plasma mass spectrometry and electrospray mass spectrometry hyphenated with ion chromatography for trace analysis of iodide

被引:14
|
作者
Buchberger, W
Czizsek, B
Hann, S
Stingeder, G
机构
[1] Johannes Kepler Univ Linz, Dept Analyt Chem, A-4040 Linz, Austria
[2] Univ Agr Sci, Inst Chem, A-1190 Vienna, Austria
关键词
D O I
10.1039/b301442h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-exchange chromatography hyphenated with mass spectrometric detection has been investigated for the determination of iodide in urine. Satisfactory chromatographic behavior of iodide could be achieved on a hydrophilic polymer-based anion-exchange column with 35 mM sodium hydroxide as the mobile phase. When electrospray ionization (ESI) was used, a suppressor as well as a flow splitter (split ratio 1:10) was required between the column and the interface. In the case of an inductively coupled plasma (ICP) ionization source, eluent and flow-rate were completely compatible with the interface. Under comparable chromatographic conditions, the ESI interface yielded a detection limit of 15 mug L-1 (quadrupole instrument), whereas the ICP interface lowered the detection limits by approximately two (quadrupole instrument) and three (sector field instrument) orders of magnitude. For urine samples both methods gave virtually the same results except for the relative standard deviation, which was 7% for ESI and 0.55% for sector field ICP. The molecule-selective detection of ESI may be an advantage in cases when insufficient separation from other iodine-containing species cannot be avoided. The element-selective ICP will be the preferred tool when iodide has to be determined in the sub-ppb range.
引用
收藏
页码:512 / 514
页数:3
相关论文
共 50 条
  • [21] Trace metal analysis of road dust by inductively coupled plasma mass spectrometry
    Powell, MJ
    Liu, L
    Gnanalingham, N
    Peters, L
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2000, 45 (5-6): : 133 - 139
  • [22] Inductively coupled plasma mass spectrometry
    Woeste, S
    LABORATORY MEDICINE, 2004, 35 (02) : 73 - 75
  • [23] Inductively coupled plasma mass spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2006, 78 (12) : 4111 - 4135
  • [24] Liquid chromatography-inductively coupled plasma mass spectrometry
    Sutton, KL
    Caruso, JA
    JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) : 243 - 258
  • [25] Analysis of selenium nanoparticles in human plasma by capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry
    Freja Grønbæk-Thorsen
    Rikke Holck Hansen
    Jesper Østergaard
    Bente Gammelgaard
    Laura Hyrup Møller
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2247 - 2255
  • [26] Trace analysis of metals in plant samples with inductively coupled plasma – mass spectrometry
    M. Leiterer
    J. W. Einax
    C. Löser
    A. Vetter
    Fresenius' Journal of Analytical Chemistry, 1997, 359 : 423 - 426
  • [27] Inductively coupled plasma mass spectrometry
    Van Acker, Thibaut
    Theiner, Sarah
    Bolea-Fernandez, Eduardo
    Vanhaecke, Frank
    Koellensperger, Gunda
    NATURE REVIEWS METHODS PRIMERS, 2023, 3 (01):
  • [28] Inductively coupled plasma mass spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2008, 80 (12) : 4455 - 4486
  • [29] Inductively coupled plasma mass spectrometry
    Thibaut Van Acker
    Sarah Theiner
    Eduardo Bolea-Fernandez
    Frank Vanhaecke
    Gunda Koellensperger
    Nature Reviews Methods Primers, 3
  • [30] Inductively coupled plasma mass spectrometry
    Beauchemin, D
    ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2873 - 2893