A selective and sensitive electrochemical determination of catechol based on reduced graphene oxide decorated β-cyclodextrin nanosheet modified glassy carbon electrode

被引:11
|
作者
Nikhil, S. [2 ]
Karthika, A. [1 ,4 ]
Suresh, P. [2 ]
Suganthi, A. [1 ]
Rajarajan, M. [3 ]
机构
[1] Thiagarajar Coll, PG & Res Dept Chem, Madurai 625009, Tamil Nadu, India
[2] Madurai Kamaraj Univ, Sch Chem, Madurai 625021, Tamil Nadu, India
[3] Madurai Kamaraj Univ, Madurai 625021, Tamil Nadu, India
[4] Latha Mathavan Arts & Sci Coll, Madurai, Tamil Nadu, India
关键词
Electrochemical studies; Reduced graphene oxide; Glassy carbon electrode; Selectivity; Real sample analysis; GOLD NANOPARTICLES; FUNCTIONALIZED GRAPHENE; SENSING PLATFORM; QUANTUM DOTS; HYDROQUINONE; COMPOSITE; BIOSENSOR; NANOCOMPOSITE; SENSOR; FILM;
D O I
10.1016/j.apt.2021.04.027
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present work, we have demonstrated the fabrication of catechol (CC) biosensor based on reduced graphene oxide (rGO) decorated beta-cyclodextrin (beta-CD) nanosheet immobilized using nafion (Nf) on modified GCE (glassy carbon electrode). The rGO/beta-CD nanocomposite is synthesized through sonochemical approach and characterized by spectral (UV-visible, FT-IR, and Raman), analytical techniques (XRD, SEM, SAED, mapping analysis, HR-TEM and EDX) and electrochemical studies. The rGO/beta-CD/Nf modified GCE exhibit a prominent electrocatalytic activity towards selective and sensitive determination of CC than other modified electrodes. Besides, the electrochemical sensor was revealed an excellent current response for the determination of CC with wide linear ranges (0.1-0.7 mu M), high sensitivity (19.1 mu A mu M(-1)cm(2)) and very low detection limit (LOD) 0.0012 mM. The excellent reproducibility, selectivity, stability, and sensitivity results are achieved for the determination of CC. (C) 2021 The Society of Powder Technology Japan. Published by Elsevier B.V. and The Society of Powder Technology Japan. All rights reserved.
引用
收藏
页码:2148 / 2159
页数:12
相关论文
共 50 条
  • [41] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306
  • [42] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [43] Simultaneous electrochemical determination of catechol and hydroquinone based on graphene-TiO2 nanocomposite modified glassy carbon electrode
    Zhang, Yanli
    Xie, Jinling
    Xiao, Shixiu
    Yang, Zhongming
    Pang, Pengfei
    Gao, Yuntao
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 102 - 108
  • [44] Electrochemical Determination of Methamphetamine in Human Plasma on a Nanoceria Nanoparticle Decorated Reduced Graphene Oxide (rGO) Glassy Carbon Electrode (GCE)
    Anvari, Laia
    Ghoreishi, Sayed Mehdi
    Faridbod, Farnoush
    Ganjali, Mohammad R.
    ANALYTICAL LETTERS, 2021, 54 (15) : 2509 - 2522
  • [45] Electrochemical Determination of Nitrite Using a Reduced Graphene Oxide-Multiwalled Carbon Nanotube-Modified Glassy Carbon Electrode
    Deng, Keqin
    Zhou, Jianhong
    Huang, Haowen
    Ling, Yulin
    Li, Chunxiang
    ANALYTICAL LETTERS, 2016, 49 (18) : 2917 - 2930
  • [46] Cerium(IV) oxide decorated on reduced graphene oxide, a selective and sensitive electrochemical sensor for fenitrothion determination
    Ensafi, Ali A.
    Noroozi, Rasool
    Zandi-Atashbar, Navid
    Rezaei, B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 245 : 980 - 987
  • [47] Fenitrothion sensing with reduced graphene oxide decorated fumed silica nanocomposite modified glassy carbon electrode
    Ozcan, Ali
    Topcuogullari, Duygu
    Ozcan, Ayca Atilir
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 179 - 185
  • [48] Highly sensitive simultaneous electrochemical determination of hydroquinone, catechol and resorcinol based on carbon dot/reduced graphene oxide composite modified electrodes
    Zhang, Wuxiang
    Zheng, Jianzhong
    Lin, Zhongqiu
    Zhong, Ling
    Shi, Jiangu
    Wei, Chan
    Zhang, Hanqiang
    Hao, Aiyou
    Hu, Shirong
    ANALYTICAL METHODS, 2015, 7 (15) : 6089 - 6094
  • [49] Modifying a Glassy Carbon Electrode with Reduced Graphene Oxide for the Determination of Levofloxacin with a Glassy
    Ghanbari, Mohammad Hossein
    Rahimi-Nasrabadi, Mehdi
    Sobati, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (02): : 189 - 200
  • [50] A glassy carbon electrode modified with reduced graphene oxide for sensitive determination of bumetanide in urine at levels required for doping analysis
    Felipe Fantinato Hudari
    Maria Valnice Boldrin Zanoni
    Microchimica Acta, 2017, 184 : 4117 - 4124