Biomechanical Evaluation of Spinal Column after Percutaneous Cement Discoplasty: A Finite Element Analysis

被引:5
|
作者
Li, Shuang [1 ,2 ]
Xu, Baoshan [3 ]
Liu, Yancheng [2 ]
Zhang, Jingyu [2 ]
Xu, Guijun [2 ]
Shao, Pengfei [5 ]
Li, Xiaoye [4 ]
Hu, Yongcheng [2 ]
Ma, Xinlong [2 ]
机构
[1] Tianjin Med Univ, Coll Orthopaed, Tianjin, Peoples R China
[2] Tianjin Univ, Tianjin Hosp, Dept Bone & Tissue Oncol, Tianjin, Peoples R China
[3] Tianjin Univ, Tianjin Hosp, Dept Minimally Invas Spine Surg, Tianjin, Peoples R China
[4] Third Cent Hosp Tianjin, Tianjin, Peoples R China
[5] Shijingshan Hosp, Dept Neurosurg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanical; Bone cement; Finite element analysis; Lumbar spinal stenosis; Percutaneous cement discoplasty; PMMA; LUMBAR INTERBODY FUSION; CAGES; IMPLANTATION; MODEL;
D O I
10.1111/os.13314
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the biomechanical properties of percutaneous cement discoplasty (PCD) in the spinal column between different implant-endplate friction. Methods A validated L3-Scarumfinite element (FE) model was modified for simulation. In the PCD model, the L4/5 level was modified based on model 1 (M1) and model 2 (M2). In M1, the interaction between bone cement and endplate was defined as face-to-face contact with a friction coefficient of 0.3; in M2, the contact was defined as a Tie constraint. 7.5 N m moments of four physiological motions and axial load of 15, 100 and 400 N preload were imposed at the top of L3. The range of motion (ROM) and interface stress analysis of endplates, annulus fibrosus and bone cement of the operated level were calculated for comparisons among the three models. Results The ROM of M1 and M2 increased when compared with the intact model during flexion (FL) (17.5% vs 10.0%), extension (EX) (8.8% vs -8.8%), left bending (LB) (19.0% vs -17.2%) and left axial rotation (LR) (34.6% vs -3.8%). The stress of annulus fibrosus in M1 and M2 decreased in FL (-48.4% vs -57.5%), EX (-25.7% vs -14.7%), LB (-47.5% vs -52.4%), LR (-61.4% vs -68.7%) and axis loading of 100 N (-41.5% vs -15.3%), and 400 N (-27.9% vs -27.3%). The stress of upper endplate of M1 and M2 increased in FL (24.6% vs 24.7%), LB (82.2% vs 89.5%), LR (119% vs 62.4%) and axis loading of 100 N (64.6% vs 45.5%), and 400 N (58.2% vs 24.3%), but was similar in EX (2.9% vs 0.3%). The stress of lower endplate of M1 and M2 increased in FL (170.9% vs 175.0%), EX (180.8% vs 207.7%), LB (302.6% vs 274.7%), LR (332.4% vs 132.8%) and axis loading of 100 N (350.7% vs 168.6%), and 400 N (165.2% vs 106.7%). Conclusion Percutaneous cement discoplasty procedure could make effect on the mobility or stiffness. The fusion of bone cement and endplate might have more biomechanical advantages, including of the decreasing rate of implant subsidence and dislocation, and the increase spine stability.
引用
收藏
页码:1853 / 1863
页数:11
相关论文
共 50 条
  • [21] Biomechanical Finite Element Analysis of Percutaneous Endoscopic Lumbar Discectomy via a Transforaminal Approach
    Wu, Zhongxuan
    Sun, Hongzhou
    Zhang, Yu
    Xiao, Liang
    Zhao, Quanlai
    WORLD NEUROSURGERY, 2024, 185 : e291 - e298
  • [22] Biomechanical evaluation of a healed acetabulum with internal fixators: finite element analysis
    Duan, Pengyun
    Ding, Xiaohong
    Xiong, Min
    Wang, Panfeng
    Xu, Shipeng
    Du, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [23] Biomechanical Evaluation of Syndesmotic Screw Position: A Finite-Element Analysis
    Verim, Ozgur
    Er, Mehmet Serhan
    Altinel, Levent
    Tasgetiren, Suleyman
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (04) : 210 - 215
  • [24] Biomechanical Evaluation of Osteoporosis Treating with Mechanical Vibrations: A Finite Element Analysis
    Liu, Yun
    Zhou, Guangquan
    Xu, Nenggui
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2019, 11 (04) : 506 - 513
  • [25] Nonlinear finite-element analysis and biomechanical evaluation of the lumbar spine
    Wong, C
    Gehrchen, PM
    Darvann, T
    Kiær, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (06) : 742 - 746
  • [26] Biomechanical evaluation of a healed acetabulum with internal fixators: finite element analysis
    Pengyun Duan
    Xiaohong Ding
    Min Xiong
    Panfeng Wang
    Shipeng Xu
    Wei Du
    Journal of Orthopaedic Surgery and Research, 18
  • [27] Biomechanical analysis and design of a dynamic spinal fixator using topology optimization: a finite element analysis
    Lin, Hung-Ming
    Liu, Chien-Lin
    Pan, Yung-Ning
    Huang, Chang-Hung
    Shih, Shih-Liang
    Wei, Shun-Hwa
    Chen, Chen-Sheng
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (05) : 499 - 508
  • [28] Biomechanical analysis and design of a dynamic spinal fixator using topology optimization: a finite element analysis
    Hung-Ming Lin
    Chien-Lin Liu
    Yung-Ning Pan
    Chang-Hung Huang
    Shih-Liang Shih
    Shun-Hwa Wei
    Chen-Sheng Chen
    Medical & Biological Engineering & Computing, 2014, 52 : 499 - 508
  • [29] Finite element model of human cervical spinal column
    Wheeldon, J
    Khouphongsy, P
    Kumaresan, S
    Yoganandan, N
    Pintar, FA
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 36, 2000, 395 : 337 - 342
  • [30] Complication Pattern After Percutaneous Cement Discoplasty: Identification of Factors Influencing Reoperation and Length of Hospital Stay
    Koch, Kristof
    Szoverfi, Zsolt
    Jakab, Gabor
    Varga, Peter Pal
    Hoffer, Zoltan
    Lazary, Aron
    WORLD NEUROSURGERY, 2023, 178 : E700 - E711