An analysis of the accuracy of the Cyberknife: A robotic nameless stereotactic radiosurgical system

被引:257
|
作者
Chang, SD
Main, W
Martin, DP
Gibbs, IC
Heilbrun, MP
机构
[1] Stanford Univ, Sch Med, Dept Neurosurg, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[3] Accuray Inc, Sunnyvale, CA USA
关键词
accuracy; radiosurgery; stereotactic;
D O I
10.1097/00006123-200301000-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The use of stereotactic radiosurgical systems to treat intracranial and extracranial tumors and other lesions requires a high degree of accuracy in target identification and localization. The purpose of this study was to evaluate the total system accuracy of the CyberKnife (Accuray, Inc., Sunnyvale, CA), a frameless, image-guided, stereotactic radiosurgery system. METHODS: Clinically relevant accuracy or application accuracy of the CyberKnife radiosurgery system is based on 1) the beam delivery accuracy, which combines the robot and the camera image tracking system, and 2) target localization accuracy, which combines computed tomographic (CT) imaging and treatment planning. Clinically relevant accuracy can be measured by delivering a radiation dose to phantoms, in which the target is defined on a set of CT images using all components of the CyberKnife system, including the treatment planning software, the robot, the camera tracking system, and the linear accelerator. Clinically relevant accuracy was measured in head phantoms loaded with packs of radiochromic film. The accuracy measured is the displacement of the dose contours from the treatment plan to that measured in the radiosurgically exposed phantom. RESULTS: Measurements of mean errors of the second-generation CyberKnife system at Stanford University Medical Center, installed in 2001, ranged from 0.7 mm for a CT slice thickness of 0.625 mm to 1.97 mm for a CT slice thickness of 3.75 mm. CONCLUSION: The frameless, image-guided, second-generation CyberKnife radiosurgery system has a clinically relevant accuracy of 1.1 +/- 0.3 mm when CT slice thicknesses of 1.25 mm are used. CyberKnife precision is comparable to published localization errors in current frame-based radiosurgical systems.
引用
收藏
页码:140 / 146
页数:7
相关论文
共 50 条
  • [1] An analysis of the accuracy of the Cyberknife:: A robotic nameless stereotactic radiosurgical system -: Comments
    Kelly, PJ
    Loeffler, JS
    Bussière, MR
    Yu, C
    NEUROSURGERY, 2003, 52 (01) : 146 - 147
  • [2] CyberKnife stereotactic radiosurgical rhizotomy for refractory trigeminal neuralgia
    Tang, Chi-Tun
    Chang, Steven D.
    Tseng, Kuan-Yin
    Liu, Ming-Ying
    Ju, Da-Tong
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (11) : 1449 - 1453
  • [3] CyberKnife® Robotic Stereotactic Radiosurgery
    Heron, D. E.
    Mintz, A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (05) : 431 - 432
  • [4] CYBERKNIFE STEREOTACTIC ROBOTIC RADIOSURGERY PREFACE
    Andrews, David W.
    NEUROSURGERY, 2009, 64 (02) : A2 - A5
  • [5] CYBERKNIFE STEREOTACTIC RADIOSURGICAL RHIZOTOMY FOR TRIGEMINAL NEURALGIA: ANATOMIC AND MORPHOLOGICAL CONSIDERATIONS
    Borchers, John D., III
    Yang, Hee-Jin
    Sakamoto, Gordon T.
    Howes, Gregory A.
    Gupta, Gaurav
    Chang, Steven D.
    Adler, John R., Jr.
    NEUROSURGERY, 2009, 64 (02) : A91 - A95
  • [7] Commissioning of a new treatment planning system for CyberKnife robotic stereotactic radiotherapy
    Jaccard, M.
    Perichon, N.
    Fargier-Voiron, M.
    Matzinger, O.
    Bulling, S.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1541 - S1542
  • [8] A robotic 3-D motion simulator for enhanced accuracy in CyberKnife stereotactic radiosurgery
    Zhou, T
    Tang, J
    Dieterich, S
    Cleary, K
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 323 - 328
  • [9] CyberKnife® Robotic Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy
    Mintz, A.
    Heron, D. E.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (06) : 539 - 540
  • [10] A Memetic Algorithm for Dosimetric Optimization in CyberKnife Robotic Radiosurgical Treatment Planning
    Clancey, Owen
    Witten, Matthew
    2011 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION (CEC), 2011, : 880 - 885