Characterisation of out-of-field dose at shallow depths for external beam radiotherapy: implications for eye lens dose

被引:0
|
作者
Baradaran, Tina C. [1 ]
Cutajar, Dean L. [1 ,2 ]
Qi, Yujin [1 ]
Ralston, Anna [1 ,2 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] St George Hosp, St George Canc Care Ctr, Kogarah, NSW, Australia
关键词
Eye lens dose; Out-of-field dose; Head leakage; Collimator scatter; Patient scatter; Shallow depths; MODULATED RADIATION-THERAPY; PHOTON BEAMS; MONTE-CARLO; COMMITTEE; ACCURACY;
D O I
10.1007/s13246-019-00764-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Re-evaluation of the eye lens radio-sensitivity by the ICRP in 2011 resulted in a significant reduction of the threshold for lens opacities from 8 Gy to 0.5 Gy. This has led to an increase in concern for eye lens doses from treatment sites further from the eye than previously considered. The aim of this study was to examine the out-of-field dose far from the field edge and develop an effective method to accurately characterise the constituent components of this dose at varying depths. Dose profile scans using a 0.6 cm(3) cylindrical ionisation chamber in a motorised water tank were compared with previous studies and displayed good agreement. At points more than 20 cm from the field edge patient scatter becomes insignificant, and the dose is dominated by head leakage and collimator scatter. Point depth-dose measurements made with a Roos parallel plate chamber in solid water at distances of 52 cm and 76 cm from central axis showed that the highest dose is at the surface. Since the sensitive region of the eye can be as shallow as 3 mm, in vivo measurements carried out with a detector with buildup more than 3 mm water equivalent thickness may be underestimating the dose to the lens. It is therefore recommended that for in vivo measurements for the eye lens further than 20 cm from the field edge the detector should have only 3 mm build-up material over the effective point of measurement.
引用
收藏
页码:671 / 676
页数:6
相关论文
共 50 条
  • [21] Out-of-field dose measurement and second cancer-risk estimation following external beam radiotherapy and brachytherapy for cervical cancer treatment: A phantom study
    Hemalatha A.
    Mayilvaganan A.
    Joan M.
    Chougule A.
    Kumar H.S.
    Iranian Journal of Medical Physics, 2020, 17 (04) : 253 - 259
  • [22] Assessment of out-of-field absorbed dose and equivalent dose in proton fields
    Clasie, Ben
    Wroe, Andrew
    Kooy, Hanne
    Depauw, Nicolas
    Flanz, Jay
    Paganetti, Harald
    Rosenfeld, Anatoly
    MEDICAL PHYSICS, 2010, 37 (01) : 311 - 321
  • [23] The out-of-field dose measurement of neutron and photon during radiotherapy with 20MV
    Kruszyna, M.
    Malicki, J.
    Adamczyk, S.
    Kowalik, A.
    Jackowiak, W.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S286 - S286
  • [24] MODELING OF FIELD PARAMETERS FOR DOSE VERIFICATION IN EXTERNAL BEAM RADIOTHERAPY
    Meijers, Arturs
    Popov, Sergey
    MEDICAL PHYSICS IN THE BALTIC STATES: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MEDICAL PHYSICS, 2009, : 56 - 59
  • [25] Assessment of accuracy of out-of-field dose calculations by TiGRT treatment planning system in radiotherapy
    Toossi, Mohammad Taghi Bahreyni
    Soleymanifard, Shokouhozaman
    Farhood, Bagher
    Mohebbi, Shokoufeh
    Davenport, David
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (03) : 634 - 639
  • [26] A multi-plane source model for out-of-field head scatter dose calculations in external beam photon therapy
    Benadjaoud, Mohamed Amine
    Bezin, Jeremi
    Veres, Attila
    Lefkopoulos, Dimitri
    Chavaudra, Jean
    Bridier, Andre
    de Vathaire, Florent
    Diallo, Ibrahima
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22): : 7725 - 7739
  • [27] Out-of-field doses in radiotherapy: Input to epidemiological studies and dose-risk models
    Harrison, Roger
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 239 - 246
  • [28] Feasibility of Gafchromic EBT3 film for measuring out-of-field dose in radiotherapy
    Viren, T.
    Saikkonen, A.
    Niemela, J.
    Keyrilainen, J.
    Salomaa, S.
    Seppala, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1002 - S1003
  • [29] Deep-Learning for Rapid Estimation of the Out-of-Field Dose in External Beam Photon Radiation Therapy - A Proof of Concept
    Benzazon, Nathan
    Carre, Alexandre
    de Kermenguy, Francois
    Niyoteka, Stephane
    Maury, Pauline
    Colnot, Julie
    M'hamdi, Meissane
    El Aichi, Mohammed
    Veres, Cristina
    Allodji, Rodrigue
    de Vathaire, Florent
    Sarrut, David
    Journy, Neige
    Alapetite, Claire
    Gregoire, Vincent
    Deutsch, Eric
    Diallo, Ibrahima
    Robert, Charlotte
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (01): : 253 - 264
  • [30] Out-of-field Dose for Scanned and Scattered Proton Beams
    Moyers, Michael F.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 456 - 459