Characterisation of out-of-field dose at shallow depths for external beam radiotherapy: implications for eye lens dose

被引:0
|
作者
Baradaran, Tina C. [1 ]
Cutajar, Dean L. [1 ,2 ]
Qi, Yujin [1 ]
Ralston, Anna [1 ,2 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] St George Hosp, St George Canc Care Ctr, Kogarah, NSW, Australia
关键词
Eye lens dose; Out-of-field dose; Head leakage; Collimator scatter; Patient scatter; Shallow depths; MODULATED RADIATION-THERAPY; PHOTON BEAMS; MONTE-CARLO; COMMITTEE; ACCURACY;
D O I
10.1007/s13246-019-00764-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Re-evaluation of the eye lens radio-sensitivity by the ICRP in 2011 resulted in a significant reduction of the threshold for lens opacities from 8 Gy to 0.5 Gy. This has led to an increase in concern for eye lens doses from treatment sites further from the eye than previously considered. The aim of this study was to examine the out-of-field dose far from the field edge and develop an effective method to accurately characterise the constituent components of this dose at varying depths. Dose profile scans using a 0.6 cm(3) cylindrical ionisation chamber in a motorised water tank were compared with previous studies and displayed good agreement. At points more than 20 cm from the field edge patient scatter becomes insignificant, and the dose is dominated by head leakage and collimator scatter. Point depth-dose measurements made with a Roos parallel plate chamber in solid water at distances of 52 cm and 76 cm from central axis showed that the highest dose is at the surface. Since the sensitive region of the eye can be as shallow as 3 mm, in vivo measurements carried out with a detector with buildup more than 3 mm water equivalent thickness may be underestimating the dose to the lens. It is therefore recommended that for in vivo measurements for the eye lens further than 20 cm from the field edge the detector should have only 3 mm build-up material over the effective point of measurement.
引用
收藏
页码:671 / 676
页数:6
相关论文
共 50 条
  • [11] Measurement of out-of-field Dose in the Hippocampus for Patients with common Radiotherapy Indications
    Auerbach, H.
    Dzierma, Y.
    Schuermann, M.
    Nuesken, F.
    Ruebe, C.
    Ruebe, C. E.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S165 - S165
  • [12] Out-of-Field dose in craniospinal irradiation
    Jalbout, W.
    Howell, R.
    Newhauser, W.
    Geara, F.
    Khater, N.
    Taddei, P.
    MEDICAL PHYSICS, 2012, 39 (07) : 4631 - 4631
  • [13] Supplemental computational phantoms to estimate out-of-field absorbed dose in photon radiotherapy
    Gallagher, Kyle J.
    Tannous, Jaad
    Nabha, Racile
    Feghali, Joelle Ann
    Ayoub, Zeina
    Jalbout, Wassim
    Youssef, Bassem
    Taddei, Phillip J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [14] Out-Of-Field Dose and Surface Dose Measurements of Mill-Guided Cobalt-60 Radiotherapy
    Lamb, J.
    Agazaryan, N.
    Cao, M.
    Low, D.
    Thomas, D.
    Yang, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3310 - 3311
  • [15] Out-Of-Field Dose Measurement for Advanced Post-Mastectomy Radiotherapy Techniques
    Yoon, J.
    Zhang, R.
    MEDICAL PHYSICS, 2017, 44 (06) : 3150 - 3150
  • [16] Low dose out-of-field radiotherapy, part 1: Measurement of scattered doses
    Kruszyna, M.
    Adamczyk, S.
    Skrobala, A.
    Skorska, M.
    Suchorska, W.
    Zaleska, K.
    Kowalik, A.
    Jackowiak, W.
    Malicki, J.
    CANCER RADIOTHERAPIE, 2017, 21 (05): : 345 - 351
  • [17] Dose calculation accuracy of radiotherapy treatment planning systems in out-of-field regions
    Farhood, B.
    Ghorbani, M.
    Journal of Biomedical Physics and Engineering, 2019, 9 (02): : 133 - 136
  • [18] Out-of-field dose measurements in a water phantom using different radiotherapy modalities
    Kaderka, R.
    Schardt, D.
    Durante, M.
    Berger, T.
    Ramm, U.
    Licher, J.
    La Tessa, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (16):
  • [19] Out-of-field dose assessment for pencil beam scanning proton radiotherapy versus photon radiotherapy for breast cancer in pregnant women
    Weessies, Menke
    Bellezzo, Murillo
    Hupkens, Britt J. P.
    Verhaegen, Frank
    Vilches-Freixas, Gloria
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 33
  • [20] The relative biological effectiveness of out-of-field dose
    Balderson, Michael
    Koger, Brandon
    Kirkby, Charles
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 114 - 130