Characterisation of out-of-field dose at shallow depths for external beam radiotherapy: implications for eye lens dose

被引:0
|
作者
Baradaran, Tina C. [1 ]
Cutajar, Dean L. [1 ,2 ]
Qi, Yujin [1 ]
Ralston, Anna [1 ,2 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] St George Hosp, St George Canc Care Ctr, Kogarah, NSW, Australia
关键词
Eye lens dose; Out-of-field dose; Head leakage; Collimator scatter; Patient scatter; Shallow depths; MODULATED RADIATION-THERAPY; PHOTON BEAMS; MONTE-CARLO; COMMITTEE; ACCURACY;
D O I
10.1007/s13246-019-00764-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Re-evaluation of the eye lens radio-sensitivity by the ICRP in 2011 resulted in a significant reduction of the threshold for lens opacities from 8 Gy to 0.5 Gy. This has led to an increase in concern for eye lens doses from treatment sites further from the eye than previously considered. The aim of this study was to examine the out-of-field dose far from the field edge and develop an effective method to accurately characterise the constituent components of this dose at varying depths. Dose profile scans using a 0.6 cm(3) cylindrical ionisation chamber in a motorised water tank were compared with previous studies and displayed good agreement. At points more than 20 cm from the field edge patient scatter becomes insignificant, and the dose is dominated by head leakage and collimator scatter. Point depth-dose measurements made with a Roos parallel plate chamber in solid water at distances of 52 cm and 76 cm from central axis showed that the highest dose is at the surface. Since the sensitive region of the eye can be as shallow as 3 mm, in vivo measurements carried out with a detector with buildup more than 3 mm water equivalent thickness may be underestimating the dose to the lens. It is therefore recommended that for in vivo measurements for the eye lens further than 20 cm from the field edge the detector should have only 3 mm build-up material over the effective point of measurement.
引用
收藏
页码:671 / 676
页数:6
相关论文
共 50 条
  • [1] Characterisation of out-of-field dose at shallow depths for external beam radiotherapy: implications for eye lens dose
    Tina C. Baradaran
    Dean L. Cutajar
    Yujin Qi
    Anna Ralston
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 671 - 676
  • [2] Analytical models for external photon beam radiotherapy out-of-field dose calculation: a scoping review
    Benzazon, Nathan
    Colnot, Julie
    de Kermenguy, Francois
    Achkar, Samir
    de Vathaire, Florent
    Deutsch, Eric
    Robert, Charlotte
    Diallo, Ibrahima
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [3] Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy
    Alabdoaburas, Mohamad M.
    Mege, Jean-Pierre
    Chavaudra, Jean
    Bezin, Jeremi Vu
    Veres, Attila
    de Vathaire, Florent
    Lefkopoulos, Dimitri
    Diallo, Ibrahima
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 435 - 448
  • [4] Out-of-field dose in stereotactic radiotherapy for paediatric patients
    Garrett, Lachlan
    Hardcastle, Nicholas
    Yeo, Adam
    Lonski, Peta
    Franich, Rick
    Kron, Tomas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 19 : 1 - 5
  • [5] Out-Of-Field Dose Measurements in Radiotherapy Using Photons and Particles
    Kaderka, R.
    Durante, M.
    Berger, T.
    Reitz, G.
    La Tessa, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3868 - 3868
  • [6] Measuring out-of-field dose to the hippocampus in common radiotherapy indications
    Auerbach, Hendrik
    Dzierma, Yvonne
    Schuermann, Michaela
    Ruebe, Christian
    Ruebe, Claudia E.
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [7] Measuring out-of-field dose to the hippocampus in common radiotherapy indications
    Hendrik Auerbach
    Yvonne Dzierma
    Michaela Schürmann
    Christian Rübe
    Claudia E. Rübe
    Radiation Oncology, 18
  • [8] Investigation of out-of-field dose in high-energy electron beams used in external radiotherapy
    Alabdoaburas, M. Mohamad
    Mege, J. P.
    Veres, A.
    Chavaudra, J.
    Lofkopoulos, D.
    Diallo, I.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S868 - S869
  • [9] A review of the impact of photon and proton external beam radiotherapy treatment modalities on the dose distribution in field and out-of-field;: implications for the long-term morbidity of cancer survivors
    Palm, Asa
    Johansson, Karl-Axel
    ACTA ONCOLOGICA, 2007, 46 (04) : 462 - 473
  • [10] Experimental evaluation of out-of-field dose for different high-energy electron beams and applicators used in external beam radiotherapy
    Gul, Osman Vefa
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215