Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques

被引:65
|
作者
Bloomgarden, DC
Fayad, ZA
Ferrari, VA
Chin, B
Sutton, MGSJ
Axel, L
机构
[1] UNIV PENN, MED CTR, DEPT RADIOL, PHILADELPHIA, PA 19104 USA
[2] UNIV PENN, MED CTR, DEPT CARDIOL, PHILADELPHIA, PA 19104 USA
[3] UNIV PENN, MED CTR, DEPT NUCL MED, PHILADELPHIA, PA 19104 USA
关键词
magnetic resonance imaging; heart; image processing; computer assisted; ventricular function; LEFT-VENTRICULAR VOLUMES; IN-VIVO VALIDATION; MAGNETIC-RESONANCE; 3-DIMENSIONAL ECHOCARDIOGRAPHY; EJECTION FRACTION; CINE; MASS; STANDARD; HEART; REPRODUCIBILITY;
D O I
10.1002/mrm.1910370510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Calculation of global cardiac function parameters has been validated using fast, segmented k-space, breath-hold, gradient-echo, magnetic resonance images. Images of phantoms, experimental animals, normal volunteers, and patients were acquired with a 1.5 T clinical scanner, Humans were imaged using two phased-array surface coils in multicoil mode, Myocardial contours were extracted using a new interactive, semi-automated method based on the active contour model method, Images were acquired in the short-axis orientation, and, using a new imaging and analysis strategy, in rotating plane long-axis orientations, to provide better definition of the valve planes and the apex, and also to reduce the number of slices (compared with the short-axis method) required to sample the whole heart, Validation was accomplished through calculation of the volumes of phantoms and left and right ventricular masses of animal hearts. Functional parameters from MRI were compared with those from echocardiograms and radionuclide angiograms in normal volunteers and patients, respectively.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 50 条
  • [41] Single breath-hold 3D contrast-enhanced method for assessment of cardiac function
    Barger, AV
    Grist, TM
    Block, WF
    Mistretta, CA
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (06) : 821 - 824
  • [42] Nonrigid Groupwise Registration for Motion Estimation and Compensation in Compressed Sensing Reconstruction of Breath-Hold Cardiac Cine MRI
    Royuela-del-Val, Javier
    Cordero-Grande, Lucilio
    Simmross-Wattenberg, Federico
    Martin-Fernandez, Marcos
    Alberola-Lopez, Carlos
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1525 - 1536
  • [43] Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition
    Chen, Weitian
    Chan, Queenie
    Wang, Yi-Xiang J.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (02) : 168 - 177
  • [44] A single breath-hold for analysis of systolic and diastolic cardiac function: TGRAPPA accelerated multiplanar Cine MR imaging at 3 Tesla
    Torleif A Sandner
    Daniel Theisen
    Kerstin U Bauner
    Konstantin Nikolaou
    Maximilian F Reiser
    Bernd J Wintersperger
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [45] Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system
    Goo, Eun-Hoe
    Kim, Sun-Ju
    Dong, Kyung-Rae
    Kim, Kwang-Choul
    Chung, Woon-Kwan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (05) : 863 - 867
  • [46] Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system
    Eun-Hoe Goo
    Sun-Ju Kim
    Kyung-Rae Dong
    Kwang-Choul Kim
    Woon-Kwan Chung
    Journal of the Korean Physical Society, 2016, 69 : 863 - 867
  • [47] Improving the accuracy of multi breath-hold diffusion tensor MRI tractography of the heart using dynamic motioncorrection
    Choukri Mekkaoui
    Sonia Nielles-Vallespin
    Marcel P Jackowski
    Peter D Gatehouse
    Dudley J Pennell
    David N Firmin
    David E Sosnovik
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [48] Thoracic and Abdominal Aortic Diameter Measurement by MRI Using Plain Axial Volumetric Interpolated Breath-hold Examination in Epidemiologic Research: A Validation Study
    Mensel, Birger
    Hegenscheid, Katrin
    Hesselbarth, Lydia
    Wenzel, Michael
    Hosten, Norbert
    Puls, Ralf
    ACADEMIC RADIOLOGY, 2012, 19 (08) : 1011 - 1017
  • [49] Simultaneous Multiparameter Mapping of the Liver in a Single Breath-Hold or Respiratory-Triggered Acquisition Using Multi-Inversion Spin and Gradient Echo MRI
    Manhard, Mary Kate
    Ramaniharan, Anandh Kilpattu
    Tkach, Jean A.
    Trout, Andrew T.
    Dillman, Jonathan R.
    Pednekar, Amol S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (04) : 1925 - 1936
  • [50] Optimizing Clinical Cardiac MRI Workflow through Single Breath-Hold Compressed Sensing Cine: An Evaluation of Feasibility and Efficiency
    Wang, Fuyan
    Zhou, Junjie
    Pu, Cailing
    Yu, Feidan
    Wu, Yan
    Zhang, Lingjie
    Ma, Siying
    Hu, Hongjie
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)