Optimizing Clinical Cardiac MRI Workflow through Single Breath-Hold Compressed Sensing Cine: An Evaluation of Feasibility and Efficiency

被引:2
|
作者
Wang, Fuyan [1 ]
Zhou, Junjie [1 ,2 ]
Pu, Cailing [1 ]
Yu, Feidan [1 ]
Wu, Yan [1 ]
Zhang, Lingjie [1 ]
Ma, Siying [1 ]
Hu, Hongjie [1 ]
机构
[1] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Radiol, Dept Dermatol,Sch Med, 3 East Qingchun Rd, Hangzhou 310016, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 4, Int Inst Med, Dept Radiol,Sch Med, 1 Shangcheng Ave, Yiwu 322000, Peoples R China
基金
中国国家自然科学基金;
关键词
cardiac magnetic resonance; compressed sensing; flip angle; examination workflow; RESOLUTION; VOLUMES;
D O I
10.3390/jcm13030753
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although compressed sensing (CS) accelerated cine holds immense potential to replace conventional cardiovascular magnetic resonance (CMR) cine, how to use CS-based cine appropriately during clinical CMR examinations still needs exploring. Methods: A total of 104 patients (46.5 +/- 17.1 years) participated in this prospective study. For each participant, a balanced steady state free precession (bSSFP) cine was acquired as a reference, followed by two CS accelerated cine sequences with identical parameters before and after contrast injection. Lastly, a CS accelerated cine sequence with an increased flip angle was obtained. We subsequently compared scanning time, image quality, and biventricular function parameters between these sequences. Results: All CS cine sequences demonstrated significantly shorter acquisition times compared to bSSFP(ref )cine (p < 0.001). The bSSFP(ref) cine showed higher left ventricular ejection fraction (LVEF) than all CS cine sequences (all p < 0.001), but no significant differences in LVEF were observed among the three CS cine sequences. Additionally, CS cine sequences displayed superior global image quality (p < 0.05) and fewer artifacts than bSSFP(ref) cine (p < 0.005). Unenhanced CS cine and enhanced CS cine with increased flip angle showed higher global image quality than other cine sequences (p < 0.005). Conclusion: Single breath-hold CS cine delivers precise biventricular function parameters and offers a range of benefits including shorter scan time, better global image quality, and diminished motion artifacts. This innovative approach holds great promise in replacing conventional bSSFP cine and optimizing the CMR examination workflow.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] CARDIAC TAGGING WITH BREATH-HOLD CINE MRI
    MCVEIGH, ER
    ATALAR, E
    MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 318 - 327
  • [2] TAG CONTRAST IN BREATH-HOLD CINE CARDIAC MRI
    REEDER, SB
    MCVEIGH, ER
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) : 521 - 525
  • [3] Nonrigid Groupwise Registration for Motion Estimation and Compensation in Compressed Sensing Reconstruction of Breath-Hold Cardiac Cine MRI
    Royuela-del-Val, Javier
    Cordero-Grande, Lucilio
    Simmross-Wattenberg, Federico
    Martin-Fernandez, Marcos
    Alberola-Lopez, Carlos
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1525 - 1536
  • [4] Whole-Heart Cine MRI in a Single Breath-Hold - A Compressed Sensing Accelerated 3D Acquisition Technique for Assessment of Cardiac Function
    Wech, T.
    Pickl, W.
    Tran-Gia, J.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Koestler, H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (01): : 37 - 41
  • [5] Feasibility of one breath-hold cardiovascular magnetic resonance compressed sensing cine for left ventricular strain analysis
    Chen, Xiaorong
    Pan, Jiangfeng
    Hu, Yi
    Hu, Hongjie
    Pan, Yonghao
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [6] Whole-Heart Single Breath-Hold Cardiac Cine: A Robust Motion-Compensated Compressed Sensing Reconstruction Method
    Royuela-del-Val, Javier
    Usman, Muhammad
    Cordero-Grande, Lucilio
    Martin-Fernandez, Marcos
    Simmross-Wattenberg, Federico
    Prieto, Claudia
    Alberola-Lopez, Carlos
    RECONSTRUCTION, SEGMENTATION, AND ANALYSIS OF MEDICAL IMAGES, 2017, 10129 : 58 - 69
  • [7] CLINICAL-EVALUATION OF BREATH-HOLD SPIRAL CINE MR IMAGING
    MCDONNELL, CH
    MEYER, CH
    HERKENS, RJ
    GLOVER, GH
    MACOVSKI, A
    RADIOLOGY, 1992, 185 : 103 - 103
  • [8] Single breath-hold real-time MR cardiac cine for evaluation of left ventricular function
    Tomoyuki Kido
    Kouki Watanabe
    Yuta Urusibata
    Masashi Nakamura
    Michaela Schmidt
    Michael O Zenge
    Teruhito Mochizuki
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [9] The effects of flip angle and gadolinium contrast agent on single breath-hold compressed sensing cardiac magnetic resonance cine for biventricular global strain assessment
    Wang, Fuyan
    Pu, Cailing
    Ma, Siying
    Zhou, Junjie
    Jiang, Yangyang
    Yu, Feidan
    Zhang, Shuheng
    Wu, Yan
    Zhang, Lingjie
    He, Chengbin
    Hu, Hongjie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [10] Single breath-hold compressed sensing real-time cine imaging to assess left ventricular motion in myocardial infarction
    Longere, Benjamin
    Chavent, Marc-Henry
    Coisne, Augustin
    Gkizas, Christos
    Pagniez, Julien
    Simeone, Arianna
    Silvestri, Valentina
    Schmidt, Michaela
    Forman, Christoph
    Montaigne, David
    Pontana, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (05) : 297 - 303