Single breath-hold compressed sensing real-time cine imaging to assess left ventricular motion in myocardial infarction

被引:5
|
作者
Longere, Benjamin [1 ,2 ]
Chavent, Marc-Henry [1 ]
Coisne, Augustin [2 ,3 ]
Gkizas, Christos [1 ]
Pagniez, Julien [1 ]
Simeone, Arianna [1 ]
Silvestri, Valentina [1 ]
Schmidt, Michaela [4 ]
Forman, Christoph [4 ]
Montaigne, David [2 ,3 ]
Pontana, Francois [1 ,2 ]
机构
[1] CHU Lille, Inst Coeur Poumon, Dept Cardiovasc Radiol, Blvd Pr Jules Leclercq, F-59000 Lille, France
[2] Univ Lille, FR3508, EGID European Genom Inst Diabet, INSERM UMR 1011,Inst Pasteur Lille, F-59000 Lille, France
[3] CHU Lille, Dept Clin Physiol & Echocardiog, Lille, France
[4] Siemens Healthcare GmbH, Erlangen, Germany
关键词
Cardiac magnetic resonance (CMR); Compressed sensing; Coronary artery disease; Magnetic resonance imaging (MRI); Myocardial infarction; CARDIAC MAGNETIC-RESONANCE; ITERATIVE RECONSTRUCTION; DIASTOLIC FUNCTION; HEART; MRI; CMR; QUANTIFICATION; RESOLUTION;
D O I
10.1016/j.diii.2020.11.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the reliability of a real-time compressed sensing (CS) cine sequence for the detection of left ventricular wall motion disorders after myocardial infarction in comparison with the reference steady-state free precession cine sequence. Materials and Methods: One hundred consecutive adult patients referred for either initial work-up or follow-up by cardiac magnetic resonance (CMR) in the context of myocardial infarction were prospectively included. There were 77 men and 23 women with a mean age of 63.12 +/- 11.3 (SD) years (range: 29-89 years). Each patient underwent the reference segmented multi-breath-hold steady-state free precession cine sequence including one short-axis stack and both vertical and horizontal long-axis slices (SSFPref) and the CS real-time single-breath-hold evaluated sequence (CSrt) providing the same slices. Wall motion disorders were independently and blindly assessed with both sequences by two radiologists, using the American Heart Association left ventricle segmentation. Paired Wilcoxon signed-rank test was used to search for differences in wall motion disorders conspicuity between both sequences and receiver operating characteristic curve (ROC) analysis was performed to assess the diagnosis performance of CSrt sequence using SSFPref as the reference method. Results: Each patient had at least one cardiac segment with wall motion abnormality on SSFPref and CSrt images. The 1700 segments analyzed with SSFPref were classified as normokinetic (360/1700; 21.2%), hypokinetic (783/1700; 46.1%), akinetic (526/1700; 30.9%) or dyskinetic (31/1700; 1.8%). Sensitivity and specificity of the CS sequence were 99.6% (95% CI: 99.1-99.9%) and 99.7% (95% CI: 98.5-100%), respectively. Area under ROC of CSrt diagnosis performance was 0.997 (95% CI: 0.993-0.999). Conclusion: CS real-time cine imaging significantly reduces acquisition time without compromising the conspicuity of left ventricular-wall motion disorders in the context of myocardial infarction. (C) 2020 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [1] Single breath-hold real-time MR cardiac cine for evaluation of left ventricular function
    Tomoyuki Kido
    Kouki Watanabe
    Yuta Urusibata
    Masashi Nakamura
    Michaela Schmidt
    Michael O Zenge
    Teruhito Mochizuki
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [2] Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold
    Tomoyuki Kido
    Teruhito Kido
    Masashi Nakamura
    Kouki Watanabe
    Michaela Schmidt
    Christoph Forman
    Teruhito Mochizuki
    Journal of Cardiovascular Magnetic Resonance, 18
  • [3] Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold
    Kido, Tomoyuki
    Kido, Teruhito
    Nakamura, Masashi
    Watanabe, Kouki
    Schmidt, Michaela
    Forman, Christoph
    Mochizuki, Teruhito
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [4] Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR Imaging
    Barkhausen, J
    Goyen, M
    Rühm, SG
    Eggebrecht, H
    Debatin, JF
    Ladd, ME
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 731 - 735
  • [5] Assessment of myocardial function with interactive non-breath-hold real-time MR imaging:: Comparison with echocardiography and breath-hold cine MR imaging
    Kühl, HP
    Spuentrup, E
    Wall, A
    Franke, A
    Schröder, J
    Heussen, N
    Hanrath, P
    Günther, RW
    Buecker, A
    RADIOLOGY, 2004, 231 (01) : 198 - 207
  • [6] Feasibility of one breath-hold cardiovascular magnetic resonance compressed sensing cine for left ventricular strain analysis
    Chen, Xiaorong
    Pan, Jiangfeng
    Hu, Yi
    Hu, Hongjie
    Pan, Yonghao
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [7] Myocardial perfusion imaging with real-time respiratory triggering: Impact of inspiration breath-hold on left ventricular functional parameters
    Ronny R. Buechel
    Lars Husmann
    Aju P. Pazhenkottil
    Rene Nkoulou
    Bernhard A. Herzog
    Irene A. Burger
    Jelena R. Ghadri
    Mathias Wolfrum
    Philipp A. Kaufmann
    Journal of Nuclear Cardiology, 2010, 17 : 848 - 852
  • [8] Myocardial perfusion imaging with real-time respiratory triggering: Impact of inspiration breath-hold on left ventricular functional parameters
    Buechel, Ronny R.
    Husmann, Lars
    Pazhenkottil, Aju P.
    Nkoulou, Rene
    Herzog, Bernhard A.
    Burger, Irene A.
    Ghadri, Jelena R.
    Wolfrum, Mathias
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (05) : 848 - 852
  • [9] Rapid evaluation of right and left ventricular function and mass using real-time True-FISP Cine MR imaging without breath-hold: Comparison with segmented True-FISP Cine MR imaging with breath-hold
    Hori, Y
    Yamada, N
    Higashi, M
    Hirai, N
    Nakatani, S
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (03) : 439 - 450
  • [10] EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING
    SAKUMA, H
    FUJITA, N
    FOO, TKF
    CAPUTO, GR
    NELSON, SJ
    HARTIALA, J
    SHIMAKAWA, A
    HIGGINS, CB
    RADIOLOGY, 1993, 188 (02) : 377 - 380