Single breath-hold compressed sensing real-time cine imaging to assess left ventricular motion in myocardial infarction

被引:5
|
作者
Longere, Benjamin [1 ,2 ]
Chavent, Marc-Henry [1 ]
Coisne, Augustin [2 ,3 ]
Gkizas, Christos [1 ]
Pagniez, Julien [1 ]
Simeone, Arianna [1 ]
Silvestri, Valentina [1 ]
Schmidt, Michaela [4 ]
Forman, Christoph [4 ]
Montaigne, David [2 ,3 ]
Pontana, Francois [1 ,2 ]
机构
[1] CHU Lille, Inst Coeur Poumon, Dept Cardiovasc Radiol, Blvd Pr Jules Leclercq, F-59000 Lille, France
[2] Univ Lille, FR3508, EGID European Genom Inst Diabet, INSERM UMR 1011,Inst Pasteur Lille, F-59000 Lille, France
[3] CHU Lille, Dept Clin Physiol & Echocardiog, Lille, France
[4] Siemens Healthcare GmbH, Erlangen, Germany
关键词
Cardiac magnetic resonance (CMR); Compressed sensing; Coronary artery disease; Magnetic resonance imaging (MRI); Myocardial infarction; CARDIAC MAGNETIC-RESONANCE; ITERATIVE RECONSTRUCTION; DIASTOLIC FUNCTION; HEART; MRI; CMR; QUANTIFICATION; RESOLUTION;
D O I
10.1016/j.diii.2020.11.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the reliability of a real-time compressed sensing (CS) cine sequence for the detection of left ventricular wall motion disorders after myocardial infarction in comparison with the reference steady-state free precession cine sequence. Materials and Methods: One hundred consecutive adult patients referred for either initial work-up or follow-up by cardiac magnetic resonance (CMR) in the context of myocardial infarction were prospectively included. There were 77 men and 23 women with a mean age of 63.12 +/- 11.3 (SD) years (range: 29-89 years). Each patient underwent the reference segmented multi-breath-hold steady-state free precession cine sequence including one short-axis stack and both vertical and horizontal long-axis slices (SSFPref) and the CS real-time single-breath-hold evaluated sequence (CSrt) providing the same slices. Wall motion disorders were independently and blindly assessed with both sequences by two radiologists, using the American Heart Association left ventricle segmentation. Paired Wilcoxon signed-rank test was used to search for differences in wall motion disorders conspicuity between both sequences and receiver operating characteristic curve (ROC) analysis was performed to assess the diagnosis performance of CSrt sequence using SSFPref as the reference method. Results: Each patient had at least one cardiac segment with wall motion abnormality on SSFPref and CSrt images. The 1700 segments analyzed with SSFPref were classified as normokinetic (360/1700; 21.2%), hypokinetic (783/1700; 46.1%), akinetic (526/1700; 30.9%) or dyskinetic (31/1700; 1.8%). Sensitivity and specificity of the CS sequence were 99.6% (95% CI: 99.1-99.9%) and 99.7% (95% CI: 98.5-100%), respectively. Area under ROC of CSrt diagnosis performance was 0.997 (95% CI: 0.993-0.999). Conclusion: CS real-time cine imaging significantly reduces acquisition time without compromising the conspicuity of left ventricular-wall motion disorders in the context of myocardial infarction. (C) 2020 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [21] Compressed sensing real-time cine imaging for assessment of ventricular function, volumes and mass in clinical practice
    Mathilde Vermersch
    Benjamin Longère
    Augustin Coisne
    Michaela Schmidt
    Christoph Forman
    Aurélien Monnet
    Julien Pagniez
    Valentina Silvestri
    Arianna Simeone
    Emma Cheasty
    David Montaigne
    François Pontana
    European Radiology, 2020, 30 : 609 - 619
  • [22] Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm
    Bernd J. Wintersperger
    Konstantin Nikolaou
    Olaf Dietrich
    Johannes Rieber
    Matthias Nittka
    Maximilian F. Reiser
    Stefan O. Schoenberg
    European Radiology, 2003, 13 : 1931 - 1936
  • [23] Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm
    Wintersperger, BJ
    Nikolaou, K
    Dietrich, O
    Rieber, J
    Nittka, M
    Reiser, MF
    Schoenberg, SO
    EUROPEAN RADIOLOGY, 2003, 13 (08) : 1931 - 1936
  • [24] Cardiac compressed sensing real-time cine for the assessment of left ventricular function: a large sample size analysis
    Wang, Zihan
    Wang, Zhaozhao
    An, Jing
    Yuan, Ying
    Pang, Jianing
    He, Yi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8785 - 8797
  • [25] Accuracy of single breath-hold cine MRI analyzed by guide-point modeling for the assessment of Left Ventricular Function
    Christina Heilmaier
    Kai Nassenstein
    Sonia Nielles-Vallespin
    Sven Zuehlsdorff
    Peter Hunold
    Joerg Barkhausen
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [26] Impact of inspiration breath-hold on left ventricular functional parameters assessed from myocardial perfusion imaging
    Buechel, Ronny
    Pazhenkottil, Aju
    Husmann, Lars
    Nkoulou, Rene
    Herzog, Bernhard
    Burger, Irene
    Ghadri, Jelena
    Kaufmann, Philipp
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [27] Cardiac functional analysis by free-breath real-time cine CMR with a spatiotemporal filtering method, TSENSE: Comparison with breath-hold cine CMR
    Yamamuro, Masaki
    Tadamura, Eiji
    Kanao, Shotaro
    Okayama, Satoshi
    Okamoto, Jun
    Urayama, Shinichi
    Kimura, Takeshi
    Komeda, Masashi
    Kita, Toru
    Togashi, Kaori
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (06) : 801 - 807
  • [28] Comparison of a Multi-Breath-Hold and a Single Breath-Hold Cine Imaging Approach for 4D Guide-Point Modeling of the Left Ventricle
    Heilmaier, C.
    Schlosser, T.
    Bruder, O.
    Nassenstein, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (09): : 780 - 787
  • [29] Real-time cine MRI of ventricular septal motion: A novel approach to assess ventricular coupling
    Francone, M
    Dymarkowski, S
    Kalantzi, M
    Bogaert, J
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 305 - 309
  • [30] Determination of left and right ventricular ejection and filling by fast cine MR imaging in the breath-hold technique in healthy subjects.
    Rominger, MB
    Bachmann, GF
    Geuer, M
    Puzik, M
    Pabst, W
    Rau, WS
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 436 - 441