Two-dimensional Fourier filtration of acoustic quantification echocardiographic images: Improved reproducibility and accuracy of automated measurements of left ventricular performance

被引:7
|
作者
Chandra, S
Garcia, MJ
Morehead, A
Thomas, JD
机构
[1] CLEVELAND CLIN FDN,DEPT CARDIOL,DIV CARDIOL RES,CARDIOVASC IMAGING CTR,CLEVELAND,OH 44195
[2] DARTMOUTH COLL SCH MED,HANOVER,NH
关键词
D O I
10.1016/S0894-7317(97)70067-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the accuracy of Fourier filtration in removing the high-frequency component of noise from acoustic quantification (AQ) echocardiographic images, we processed 800 parasternal short-axis images obtained from 10 study subjects. M-mode tracings were also obtained and used as gold standard for correlating the results from raw AQ and Fourier-filtered images. Left ventricular short-axis diameters measured from the raw AQ and Fourier-filtered data were compared with the M-mode diameters (r = 0.91, p < 0.001 for raw AQ; and r = 0.96, p < 0.001, for Fourier filtered images). Fractional shortening showed better correlation between Fourier-filtered images and M-mode (r = 0.79, p < 0.03) versus raw AQ and M-mode (r = 0.33, p = 0.46). Beat-to-beat reproducibility was also found to be better for fractional area change (r = 0.82, p = 0.01 versus r = 0.66, p = 0.07), peak area filling rate (r = 0.87, p = 0.004 versus p = 0.62, p = 0.1), and peak area emptying rate (r = 0.99, P < 0.0001 versus r = 0.19, p < 0.7) for Fourier filtered versus raw AQ. Our results indicate that Fourier filtration of AQ data results in more accurate representation of the true endocardial borders.
引用
收藏
页码:310 / 319
页数:10
相关论文
共 50 条
  • [21] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC IMAGING OF LEFT-VENTRICULAR MURAL VEGETATIONS
    HERZOG, CA
    CARSON, P
    MICHAUD, L
    ASINGER, RW
    AMERICAN HEART JOURNAL, 1988, 115 (03) : 684 - 686
  • [22] LEFT-VENTRICULAR MURAL THROMBUS - TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS
    REEDER, GS
    TAJIK, AJ
    SEWARD, JB
    MAYO CLINIC PROCEEDINGS, 1981, 56 (02) : 82 - 86
  • [23] Two-dimensional echocardiographic measures of left ventricular dimensions agree with M-mode measurements in dogs
    Rishniw, M.
    Corda, A.
    Spina, F.
    Caivano, D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2021, 33 : 69 - 75
  • [24] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ASSESSMENT FOR RIGHT VENTRICULAR VOLUME AND PERFORMANCE
    KUWAKO, K
    MATSUDA, M
    SAKUMA, T
    IIDA, K
    SUGISHITA, Y
    ITO, I
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1983, 47 (08): : 983 - 983
  • [25] Automated left atrial volume measurement by two-dimensional speckle-tracking echocardiography: feasibility, accuracy, and reproducibility
    Florescu, Diana R.
    Badano, Luigi P.
    Tomaselli, Michele
    Torlasco, Camilla
    Tartea, Georgica C.
    Balseanu, Tudor A.
    Volpato, Valentina
    Parati, Gianfranco
    Muraru, Denisa
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2021, 23 (01) : 85 - 94
  • [26] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENTS OF THE LEFT ATRIUM IN DOGS WITH CARDIAC DISEASE
    Dudas-Gyorki, Zoltan
    Bende, Boglarka
    Hetyey, Csaba
    Manczur, Ferenc
    Reiczigel, Jeno
    Voros, Karoly
    ACTA VETERINARIA HUNGARICA, 2009, 57 (02) : 203 - 215
  • [27] Comparison of two-dimensional echocardiographic measurements of the left atrium in healthy dogs
    Hetyey, C
    Vörös, K
    Reiczigel, J
    ACTA VETERINARIA HUNGARICA, 2005, 53 (01) : 23 - 33
  • [28] TWO-DIMENSIONAL ACOUSTIC FOURIER-TRANSFORM OF OPTICAL-IMAGES
    GAUTIER, H
    LEDU, P
    MAERFELD, C
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1980, 27 (03): : 161 - 161
  • [29] Usefulness of automated quantitation of regional left ventricular wall motion by a novel method of two-dimensional echocardiographic tracking
    Ogawa, Keitaro
    Hozumi, Takeshi
    Sugioka, Kenichi
    Matsumura, Yoshiki
    Nishiura, Masahide
    Kanda, Ryoichi
    Abe, Yasuhiko
    Takemoto, Yasuhiko
    Yoshiyama, Minoru
    Yoshikawa, Junichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (11): : 1531 - 1537
  • [30] Validity and reproducibility of echocardiographic measurement of left ventricular ejection fraction by acoustic quantification with tissue harmonic imaging technique
    Tsujita-Kuroda, K
    Zhang, GC
    Sumita, Y
    Hirooka, K
    Hanatani, A
    Nakatani, S
    Yasumura, Y
    Miyatake, K
    Yamagishi, M
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (04) : 300 - 305