Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation

被引:20
|
作者
Bernhardt, Peter [1 ]
Rodewald, Christoph [1 ]
Seeger, Julia [1 ]
Gonska, Birgid [1 ]
Buckert, Dominik [1 ]
Radermacher, Michael [1 ]
Hombach, Vinzenz [1 ]
Rottbauer, Wolfgang [1 ]
Woehrle, Jochen [1 ]
机构
[1] Univ Ulm, Dept Internal Med 2, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Magnetic resonance imaging; Transcatheter aortic valve implantation; ACUTE KIDNEY INJURY; MR-ANGIOGRAPHY; STENOSIS; ECHOCARDIOGRAPHY; ACETYLCYSTEINE; QUANTIFICATION; DISEASE; ANNULUS; RISK;
D O I
10.1007/s00392-015-0920-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Correct sizing of the aortic annulus in aortic valve stenosis is crucial for successful transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) seems to be most promising imaging modality for this pre-interventional diagnostic work-up, but has the disadvantage of exposing mostly co-morbid patients to iodine and nephrotoxic contrast agents. To establish a useful sizing method for TAVI without the use of contrast media, we compared measurements of a non-contrast magnetic resonance imaging (MRI) technique with MSCT serving as the reference standard. Fifty-two patients who underwent TAVI were previously examined with MSCT and MRI, respectively. MRI examination included a 3D steady-state free-precession sequence covering the entire ascending aorta. Perimeter and area of the aortic root were analyzed by two blinded readers in consensus using a dedicated software. Decisions for Sapien 3 valve size of both imaging modalities were compared using the mean derived annulus diameter. Mean age of the study cohort was 82.2 +/- A 4.9 years, log EuroScore was 25.2 +/- A 4.8 %. Mean aortic annulus perimeter as measured by MSCT was 76.7 +/- A 6.9 mm. MRI yielded a mean perimeter of 76.5 +/- A 6.7 mm with a good correlation coefficient (r = 0.93, p < 0.0001). Decision for valve size showed good correlation between both imaging modalities (r = 0.94, p < 0.0001). In conclusion, non-contrast MRI shows good correlation to MSCT in the assessment of the aortic annulus and valve sizing. This non-contrast technique might be a reasonable alternative for aortic root sizing before TAVI without the use of nephrotoxic contrast agents, especially in patients with severely reduced kidney function.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [41] Demonstration of cardiac involvement of sarcoidosis by contrast-enhanced multislice computed tomography and delayed-enhanced magnetic resonance imaging
    Kanao, S
    Tadamura, E
    Yamamuro, M
    Kubo, S
    Kimura, T
    Kita, T
    Togashi, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (06) : 745 - 748
  • [42] Comparison of high resolution ultrafast (electron beam) computed tomography angiography and ultrafast contrast-enhanced magnetic resonance angiography in the evaluation of abdominal aortic aneurysms
    Neff, W
    Lehmann, KJ
    Weisser, G
    Diehl, SJ
    Gaa, JA
    Georgi, M
    RADIOLOGY, 1998, 209P : 495 - 496
  • [43] Transport of contrast agents in contrast-enhanced magnetic resonance angiography
    Jou, LD
    Rapp, J
    Saloner, D
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 495 - 504
  • [44] Contrast-Enhanced Spectral Detector Computed Tomography in the detection of Myocardial Fibrosis: Comparison to Contrast-Enhanced Magnetic Resonance
    Defaee, Asefeh
    Gerber, Berhard
    ACTA CARDIOLOGICA, 2020, 75 : 28 - 29
  • [45] CONTRAST-ENHANCED MAGNETIC-RESONANCE ANGIOGRAPHY
    VOGL, TJ
    HOFFMANN, Y
    MUHLER, A
    FELIX, A
    RADIOLOGE, 1994, 34 (08): : 423 - 429
  • [46] The feasibility of relaxation-enhanced angiography without contrast and triggering for preprocedural planning of transcatheter aortic valve implantation
    Wang, Rui
    Liu, Xinmin
    Yao, Jing
    Schoepf, U. Joseph
    Griffith, Joseph
    Wang, Jiayang
    Lian, Jianxiu
    Jiang, Ke
    Song, Guangyuan
    Xu, Lei
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [47] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, Oliver
    Holzamer, Andreas
    Resch, Markus
    Endemann, Dierk H.
    Nunez, Julio
    Bodi, Vicente
    Schmid, Christof
    Riegger, Guenter A. J.
    Goessmann, Holger
    Hamer, Okka
    Stroszczynski, Christian
    Luchner, Andreas
    Hilker, Michael
    Hengstenberg, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3431 - 3438
  • [48] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, O.
    Holzamer, A.
    Nunez, J.
    Bodi, V.
    Schmid, C.
    Riegger, G. A. J.
    Hamer, O.
    Stroszczynski, C.
    Hilker, M.
    Hengstenberg, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 577 - 577
  • [49] ACCURACY AND REPRODUCIBILITY OF CONTRAST ENHANCED AND NON-ENHANCED COMPUTED TOMOGRAPHY FOR PREDICTING THE ANGIOGRAPHIC DEPLOYMENT ANGLE IN TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR)
    Dao, Catherine N.
    Blake, Theodore
    Liang, David
    Fischbein, Michael P.
    Yeung, Alan
    Fearon, William
    Miller, D. Craig
    Fleischmann, Dominik
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1195 - E1195
  • [50] Preparative fasting before contrast-enhanced computed tomography
    Yong, Hwan Seok
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2020, 63 (03): : 151 - 154