Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation

被引:20
|
作者
Bernhardt, Peter [1 ]
Rodewald, Christoph [1 ]
Seeger, Julia [1 ]
Gonska, Birgid [1 ]
Buckert, Dominik [1 ]
Radermacher, Michael [1 ]
Hombach, Vinzenz [1 ]
Rottbauer, Wolfgang [1 ]
Woehrle, Jochen [1 ]
机构
[1] Univ Ulm, Dept Internal Med 2, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Magnetic resonance imaging; Transcatheter aortic valve implantation; ACUTE KIDNEY INJURY; MR-ANGIOGRAPHY; STENOSIS; ECHOCARDIOGRAPHY; ACETYLCYSTEINE; QUANTIFICATION; DISEASE; ANNULUS; RISK;
D O I
10.1007/s00392-015-0920-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Correct sizing of the aortic annulus in aortic valve stenosis is crucial for successful transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) seems to be most promising imaging modality for this pre-interventional diagnostic work-up, but has the disadvantage of exposing mostly co-morbid patients to iodine and nephrotoxic contrast agents. To establish a useful sizing method for TAVI without the use of contrast media, we compared measurements of a non-contrast magnetic resonance imaging (MRI) technique with MSCT serving as the reference standard. Fifty-two patients who underwent TAVI were previously examined with MSCT and MRI, respectively. MRI examination included a 3D steady-state free-precession sequence covering the entire ascending aorta. Perimeter and area of the aortic root were analyzed by two blinded readers in consensus using a dedicated software. Decisions for Sapien 3 valve size of both imaging modalities were compared using the mean derived annulus diameter. Mean age of the study cohort was 82.2 +/- A 4.9 years, log EuroScore was 25.2 +/- A 4.8 %. Mean aortic annulus perimeter as measured by MSCT was 76.7 +/- A 6.9 mm. MRI yielded a mean perimeter of 76.5 +/- A 6.7 mm with a good correlation coefficient (r = 0.93, p < 0.0001). Decision for valve size showed good correlation between both imaging modalities (r = 0.94, p < 0.0001). In conclusion, non-contrast MRI shows good correlation to MSCT in the assessment of the aortic annulus and valve sizing. This non-contrast technique might be a reasonable alternative for aortic root sizing before TAVI without the use of nephrotoxic contrast agents, especially in patients with severely reduced kidney function.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [21] FIBROCALCIFIC VOLUME IN AORTIC VALVE STENOSIS USING CONTRAST-ENHANCED COMPUTED TOMOGRAPHY
    Joshi, Shruti
    Lembo, Maria
    Bing, Rong
    Carnevale, Lorenzo
    Tzolos, Evangelos
    Pawade, Tania A.
    Doris, Mhairi K.
    Dey, Damini
    Newby, David E.
    Dweck, Marc R.
    HEART, 2022, 108 : A106 - A108
  • [22] Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy
    Trinh, Brian
    Dubin, Iram
    Rahman, Ozair
    Botelho, Marcos P. Ferreira
    Naro, Nicholas
    Carr, James C.
    Collins, Jeremy D.
    Barker, Alex J.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (04) : 216 - 222
  • [23] Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children
    Zhong, Yumin
    Jaffe, Richard B.
    Zhu, Ming
    Sun, Aimin
    Li, Yuhua
    Gao, Wei
    PEDIATRIC RADIOLOGY, 2007, 37 (03) : 256 - 263
  • [24] Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children
    Yumin Zhong
    Richard B. Jaffe
    Ming Zhu
    Aimin Sun
    Yuhua Li
    Wei Gao
    Pediatric Radiology, 2007, 37 : 256 - 263
  • [25] Feasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement: A Comparison With Contrast-Enhanced Computed Tomography
    Suh, Young Joo
    Lee, Sak
    Hong, Geu-Ru
    Ko, Young-Guk
    Hong, Myeong-Ki
    Kim, Young Jin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 50 - 55
  • [26] Non-contrast-enhanced magnetic resonance angiography: techniques and applications
    Blankholm, Anne Dorte
    Ringgaard, Steffen
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2012, 10 (01) : 75 - 88
  • [27] Sex difference in aortic valve fibrosis assessed by contrast-enhanced computed tomography in severe aortic stenosis
    Myasoedova, V.
    Fraschini, E.
    Mostardini, G.
    Bonfanti, L.
    Chiesa, M.
    De Pasquale, C.
    Olivares, P.
    Trabattoni, D.
    Bartorelli, A. L.
    Andreini, D.
    Poggio, P.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1618 - 1618
  • [28] Contrast-Enhanced Magnetic Resonance Angiography
    Vasile, Julie V.
    Newman, Tiffany M.
    Prince, Martin R.
    Rusch, David G.
    Greenspun, David T.
    Allen, Robert J.
    Levine, Joshua L.
    CLINICS IN PLASTIC SURGERY, 2011, 38 (02) : 263 - +
  • [29] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +
  • [30] Contrast-enhanced magnetic resonance angiography
    Roditi, G
    BRITISH JOURNAL OF SURGERY, 2002, 89 (07) : 817 - 820