Numerical investigation on the capacity and efficiency of a deep enhanced U-tube borehole heat exchanger system for building heating

被引:53
|
作者
Chen, Chaofan [1 ,2 ]
Cai, Wanlong [1 ,3 ]
Naumov, Dmitri [1 ,4 ]
Tu, Kun [5 ,6 ]
Zhou, Hongwei [6 ]
Zhang, Yuping [3 ,7 ]
Kolditz, Olaf [1 ,2 ]
Shao, Haibing [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[2] Tech Univ Dresden, Appl Environm Syst Anal, D-01069 Dresden, Germany
[3] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[4] Freiberg Univ Min & Technol, D-09599 Freiberg, Germany
[5] Univ Calif Riverside, Dept Environm Sci, Riverside, CA 92521 USA
[6] China Univ Min & Technol Beijing, Beijing 100083, Peoples R China
[7] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Geothermal energy; Building heating; Enhanced U-tube borehole heat exchanger; Long-term thermal performance; Efficiency; THERMAL PERFORMANCE; BEND PIPE; SUSTAINABILITY; EXTRACTION; EQUATIONS; MODEL; FLUID; FIELD; FLOW; MASS;
D O I
10.1016/j.renene.2021.01.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Deep geothermal energy has become widely exploited in recent years through the use of closed loop systems for building heating. Intended to meet high heating demand in densely populated neighbourhoods, an enhanced U-tube borehole heat exchanger (EUBHE) system, in which a deviated deep borehole is connected with another vertical one to form a closed loop, is introduced in this work. For capacity and efficiency analysis of applying EUBHE systems to extract deep geothermal energy, a 3D numerical model is implemented and established based on the OpenGeoSys software. Through evaluation by thermal performance tests and thermal response tests on the EUBHE system, the maximum sustainable heat extraction rate is found to be 1.2 MW in a single heating season and 1.1 MW in 10 years, which can provide heating to more than 35,000 m(2) of residential buildings located in northern China. Moreover, the 10-year system thermal performance and efficiency are evaluated when coupled with a ground source heat pump (GSHP), and compared with the two deep borehole heat exchanger (2-DBHE) array system that has the same total borehole length as the EUBHE system. Results show that GSHP-coupled EUBHE system is more efficient than the 2-DBHE array system, as it consumes 27% less electricity. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:557 / 572
页数:16
相关论文
共 50 条
  • [41] Performance of a hybrid heating system based on enhanced deep borehole heat exchanger and solar energy
    Yujiang He
    Xianbiao Bu
    Geothermal Energy, 10
  • [42] Analysis of deep borehole heat exchanger with horizontal branch wells for building heating
    Li, Huashan
    Huang, Sihao
    Bu, Xianbiao
    Wang, Lingbao
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (04) : 1164 - 1169
  • [43] Transient heat transfer simulation, analysis and thermal performance study of double U-tube borehole heat exchanger based on numerical heat transfer model
    Kerme, Esa Dube
    Fung, Alan S.
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [44] Theoretical Study on Arrangement Depth of U-Tube Heat Exchanger under Building Foundation
    Song, Wei
    Zheng, Tuanfeng
    Wang, Meilin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3164 - 3171
  • [45] Short-term fluid temperature variations in either a coaxial or U-tube borehole heat exchanger
    Gordon, David
    Bolisetti, Tirupati
    Ting, David S. -K.
    Reitsma, Stanley
    GEOTHERMICS, 2017, 67 : 29 - 39
  • [46] New g-functions for the hourly simulation of double U-tube borehole heat exchanger fields
    Zanchini, E.
    Lazzari, S.
    ENERGY, 2014, 70 : 444 - 455
  • [47] Thermo-Hydraulic Performance of U-Tube Borehole Heat Exchanger with Different Cross-Sections
    Zhou, Aizhao
    Huang, Xianwen
    Wang, Wei
    Jiang, Pengming
    Li, Xinwei
    SUSTAINABILITY, 2021, 13 (06)
  • [48] Numerical analysis of characteristics of a single U-tube downhole heat exchanger in a geothermal well
    Lyu, Zehao
    Song, Xianzhi
    Li, Gensheng
    Shi, Yu
    Mu, Zihan
    GEOTHERMICS, 2018, 72 : 15 - 23
  • [49] New global thermal numerical model of vertical U-tube ground heat exchanger
    Chwieduk, Michal
    RENEWABLE ENERGY, 2021, 168 : 343 - 352
  • [50] Numerical simulation on heat transfer performance of vertical U-tube with different borehole fill materials
    Fang Liu
    Tao Guo
    Yong Wang
    Miao-cheng Weng
    Journal of Central South University of Technology, 2006, 13 : 234 - 237