Diffuse luminance flicker increases retinal vessel diameter in humans

被引:89
|
作者
Formaz, F
Riva, CE
Geiser, M
机构
[1] INST RECH OPHTALMOL,CH-1950 SION 4,SWITZERLAND
[2] UNIV LAUSANNE,SCH MED,CH-1015 LAUSANNE,SWITZERLAND
[3] ECOLE INGN VALAIS,SION,SWITZERLAND
关键词
retinal diameter; flicker; neuronal activity; retinal blood flow;
D O I
10.1076/ceyr.16.12.1252.5021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To determine retinal vessel diameter variations in response to neuronal activity induced by diffuse luminance flicker. Methods. The diameter of retinal arteries and veins was measured in 9 normal subjects by computer analysis of fundus pictures taken in monochromatic light under normal conditions of illumination and after 1 min of sinusoidally varying diffuse luminance flicker at 10 Hz. Results. The diameter immediately after flicker was significantly larger than the pre-stimulus diameter by 4.2 +/- 2.2% for the retinal arteries and 2.7 +/- 1.7% for the retinal veins (mean +/- SD). Six s after cessation of the flicker, arterial diameter was not significantly different from that of pre-flicker value. Conclusions. Diffuse luminance flicker induces an increase in retinal vessel diameter. This increase most probably reflects an increase in retinal blood flow previously evidenced in humans by the blue field simulation technique. The technique needs to be optimized in terms of flicker parameters, to determine whether flicker-evoked retinal diameter changes could represent a useful clinical measure of the capability of the retinal vascular system to vasodilate.
引用
收藏
页码:1252 / 1257
页数:6
相关论文
共 50 条
  • [31] Dynamic retinal vessel response to flicker in obesity: A methodological approach
    Kotliar, Konstantin E.
    Lanzl, Ines M.
    Schmidt-Trucksaess, Arno
    Sitnikova, Diana
    Ali, Mohammad
    Blume, Katharina
    Halle, Martin
    Hanssen, Henner
    MICROVASCULAR RESEARCH, 2011, 81 (01) : 123 - 128
  • [32] Feature Extraction Method of Retinal Vessel Diameter
    Hoque, Mohammed Enamul
    Kipli, Kuryati
    Zulcaffle, Tengku Mohd Afendi
    Sapawi, Rohana
    Joseph, Annie
    Abidin, Wan Azlan Wan Zainal
    Sahari, Siti Kudnie
    2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2018, : 279 - 283
  • [33] RETINAL VESSEL DIAMETER CHANGES IN THE CARDIAC CYCLE
    CHEN, HC
    WIEK, J
    RASSAM, SMB
    PATEL, V
    KOHNER, EM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 811 - 811
  • [34] Method for retinal vessel detection and diameter measurement
    Li, XK
    Fang, T
    Tyan, JK
    Fang, M
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1746 - 1754
  • [35] Reliability of vessel diameter measurements with a retinal oximeter
    Renata Blondal
    Margret Kara Sturludottir
    Sveinn Hakon Hardarson
    Gisli Hreinn Halldorsson
    Einar Stefánsson
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 1311 - 1317
  • [36] Reliability of vessel diameter measurements with a retinal oximeter
    Blondal, Renata
    Sturludottir, Margret Kara
    Hardarson, Sveinn Hakon
    Halldorsson, Gisli Hreinn
    Stefansson, Einar
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) : 1311 - 1317
  • [37] Retinal vessel diameter measurement in multimodal imaging
    Seidel, Gerald
    Singer, Christoph
    Herzog, Sereina Annik
    Garhofer, Gerhard
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [38] Retinal Vessel Oxygen Saturation and Vessel Diameter in Inactive Graves Ophthalmopathy
    Yang, Xiaonan
    Huang, Danping
    Ai, Siming
    Liang, Xuanwei
    Zhao, Jing
    Fang, Lei
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (06): : 459 - 465
  • [39] Retinal Venous Oxygen Saturation Increases by Flicker Light Stimulation
    Hammer, Martin
    Vilser, Walthard
    Riemer, Thomas
    Liemt, Fanny
    Jentsch, Susanne
    Dawczynski, Jens
    Schweitzer, Dietrich
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (01) : 274 - 277
  • [40] Raspberry Pi controlled flicker stimulation in dynamic retinal vessel analysis
    Link, Dietmar
    Klee, Sascha
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)