Diffuse luminance flicker increases retinal vessel diameter in humans

被引:89
|
作者
Formaz, F
Riva, CE
Geiser, M
机构
[1] INST RECH OPHTALMOL,CH-1950 SION 4,SWITZERLAND
[2] UNIV LAUSANNE,SCH MED,CH-1015 LAUSANNE,SWITZERLAND
[3] ECOLE INGN VALAIS,SION,SWITZERLAND
关键词
retinal diameter; flicker; neuronal activity; retinal blood flow;
D O I
10.1076/ceyr.16.12.1252.5021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To determine retinal vessel diameter variations in response to neuronal activity induced by diffuse luminance flicker. Methods. The diameter of retinal arteries and veins was measured in 9 normal subjects by computer analysis of fundus pictures taken in monochromatic light under normal conditions of illumination and after 1 min of sinusoidally varying diffuse luminance flicker at 10 Hz. Results. The diameter immediately after flicker was significantly larger than the pre-stimulus diameter by 4.2 +/- 2.2% for the retinal arteries and 2.7 +/- 1.7% for the retinal veins (mean +/- SD). Six s after cessation of the flicker, arterial diameter was not significantly different from that of pre-flicker value. Conclusions. Diffuse luminance flicker induces an increase in retinal vessel diameter. This increase most probably reflects an increase in retinal blood flow previously evidenced in humans by the blue field simulation technique. The technique needs to be optimized in terms of flicker parameters, to determine whether flicker-evoked retinal diameter changes could represent a useful clinical measure of the capability of the retinal vascular system to vasodilate.
引用
收藏
页码:1252 / 1257
页数:6
相关论文
共 50 条
  • [21] Retinal vessel diameter - Author reply
    Wong, TY
    OPHTHALMOLOGY, 2006, 113 (05) : 887 - 887
  • [22] Retinal Vessel Diameter at High Altitude
    Willmann, Gabriel
    Schatz, Andreas
    Fischer, M. Dominik
    Schommer, Kai
    Zrenner, Eberhart
    Bartz-Schmidt, Karl-Ulrich
    Gekeler, Florian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [23] Influence of luminance flicker on blood velocity of the central retinal artery and vein
    Harazny, J
    Michelson, G
    Patzelt, A
    Welzenbach, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3614 - 3614
  • [24] SENSITIVITY OF MACAQUE RETINAL GANGLION-CELLS TO CHROMATIC AND LUMINANCE FLICKER
    LEE, BB
    MARTIN, PR
    VALBERG, A
    JOURNAL OF PHYSIOLOGY-LONDON, 1989, 414 : 223 - 243
  • [25] Influence of diffuse luminance flicker on choroidal and optic nerve head blood flow
    Garhöfer, G
    Huemer, KH
    Zawinka, C
    Schmetterer, L
    Dorner, GT
    CURRENT EYE RESEARCH, 2002, 24 (02) : 109 - 113
  • [26] Retinal vessel oxygen saturation and vessel diameter in high myopia
    Zheng, Qishan
    Zong, Yao
    Li, Li
    Huang, Xia
    Lin, Leilei
    Yang, Wei
    Yuan, Yongguang
    Li, Yujie
    He, Huining
    Gao, Qianying
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2015, 35 (05) : 562 - 569
  • [27] Retinal vessel oxygen saturation and vessel diameter in retinitis pigmentosa
    Eysteinsson, Thor
    Hardarson, Sveinn H.
    Bragason, David
    Stefansson, Einar
    ACTA OPHTHALMOLOGICA, 2014, 92 (05) : 449 - 453
  • [28] A method of vessel tracking for vessel diameter measurement on retinal images
    Gao, XH
    Bharath, A
    Stanton, A
    Hughes, A
    Chapman, N
    Thom, S
    2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2001, : 881 - 884
  • [29] Effect of Diffuse Luminance Flicker Light Stimulation on Total Retinal Blood Flow Assessed With Dual-Beam Bidirectional Doppler OCT
    Aschinger, Gerold C.
    Schmetterer, Leopold
    Fondi, Klemens
    Dos Santos, Valentin Aranha
    Seidel, Gerald
    Garhofer, Gerhard
    Werkmeister, Rene M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (02) : 1167 - 1178
  • [30] ADAPTATION OF A COLOR-OPPONENT MECHANISM INCREASES PARAFOVEAL SENSITIVITY TO LUMINANCE FLICKER
    COLETTA, NJ
    ADAMS, AJ
    VISION RESEARCH, 1986, 26 (08) : 1241 - 1248