Establishment of inherent stability on piracetam by UPLC/HPLC and development of a validated stability-indicating method

被引:4
|
作者
Sahu, Kapendra [1 ]
Shaharyar, Mohammad [1 ]
Siddiqui, Anees A. [1 ]
Sahu, Shikha [2 ]
机构
[1] Jamia Hamdard, Dept Pharmaceut Chem, Fac Pharm, New Delhi 110062, India
[2] Govt Autonomous Girls PG Coll Excellence, Dept Chem, Sagar 470002, Madhya Pradesh, India
关键词
Piracetam; Stress testing; Stability indicating assay; Validation; UPLC; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; STRESS DEGRADATION; ICH GUIDANCE; ASSAY;
D O I
10.1016/j.arabjc.2012.11.003
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel comparative force degradation UPLC assay method was developed and validated for Piracetam and its degradation products. Piracetam was subjected to acid (5M HCl), neutral (water) and alkaline (0.5 MNaOH) hydrolytic conditions at 80 degrees C, as well as to oxidative decomposition (H2O2) at room temperature. Photolytic studies were carried out by exposing this drug into sunlight (60,000-70,000 lux) for 2 d. Additionally, the solid drug was subjected to 50 degrees C for 60 days in a hot air oven for thermal degradation. The UPLC chromatographic separation was performed on Acquity UPLC BEH C18 column (1.7 mu m, 2.1 mm x 150 mm) using isocratic mode (ACN: water, 25: 75 v/v) at a flow rate of 0.15 mL min(-1) and HPLC chromatographic separation was achieved on phenomenex C18 using isocratic mode (ACN: 10 mM ammonium acetate, pH 5.0, 20: 80 v/v) at a flow rate of 0.9 mL/min. Piracetam was found to degrade only in the base and shows stable behavior under all stress conditions. The UPLC and HPLC linearity of the proposed method was investigated in the range of 10-50 mu g mL(-1). The r(2) value of UPLC and HPLC was found to be 0.999 and 0.999, respectively. Method detection limit (MDL) and Method quantification limit (MQL) were found to be 0.180 mu g mL(-1) and 1.10 mu g mL(-1) for UPLC and 0.500 mu g mL(-1) and 1.700 mu g mL(-1) for HPLC respectively. The % RSD values for intra-day and inter-day precision were < 1.2%, confirming that the method was sufficiently precise. The validation studies were carried out fulfilling ICH requirements. The developed method was simple, fast, accurate and precise and hence could be applied for routine quality control analysis of Piracetam in solid dosage forms. (C) 2012 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:S576 / S582
页数:7
相关论文
共 50 条
  • [41] A stability-indicating HPLC assay method for budesonide
    Hou, SG
    Hindle, M
    Byron, PR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (03) : 371 - 380
  • [42] A Validated and Stability-Indicating LC Assay Method for Valdecoxib
    T. Satyanarayana Raju
    K. S. V. Raghavachary
    A. Raghupathi Reddy
    M. Satish Varma
    M. Ravikumar
    P. Yadagiri Swamy
    Chromatographia, 2009, 69 : 507 - 511
  • [43] A validated, stability-indicating, LC method for rabeprazole sodium
    Buchireddy, Reguri
    Mukkanti, Khagga
    Srinivasulu, Polisetty
    Srinivas, Koduri S. V.
    CHROMATOGRAPHIA, 2008, 68 (3-4) : 275 - 280
  • [44] Validated stability-indicating TLC method for the determination of noscapine
    Ashour, Ahmed
    Hegazy, Maha Abdel Monem
    Moustafa, Azza Aziz
    Kelani, Khadiga Omar
    Fattah, Laila Elsayed Abdel
    DRUG TESTING AND ANALYSIS, 2009, 1 (7-8) : 327 - 338
  • [45] A Validated, Stability-Indicating, LC Method for Rabeprazole Sodium
    Reguri Buchireddy
    Khagga Mukkanti
    Polisetty Srinivasulu
    Koduri S. V. Srinivas
    Chromatographia, 2008, 68 : 275 - 280
  • [46] A Validated, Stability-Indicating HPTLC Method for Analysis of Doxofylline
    Narendra G. Patre
    L. Sathiyanarayanan
    Mahadeo V. Mahadik
    Sunil R. Dhaneshwar
    JPC – Journal of Planar Chromatography – Modern TLC, 2009, 22 : 345 - 348
  • [47] A Validated, Stability-Indicating HPTLC Method for Analysis of Doxofylline
    Patre, Narendra G.
    Sathiyanarayanan, L.
    Mahadik, Mahadeo V.
    Dhaneshwar, Sunil R.
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2009, 22 (05) : 345 - 348
  • [48] A Validated Stability-indicating RP-HPLC Method for Analysis of Azelaic Acid in Pharmaceuticals
    Malik, D. S.
    Kaur, G.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 80 (03) : 503 - 509
  • [49] Validated Stability-Indicating HPLC Method for the Separation of Pindolol Enantiomers and Its Related Substances
    Pujeri, S. S.
    Khader, A. M. A.
    Seetharamappa, J.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2011, 19 (01) : 73 - 84
  • [50] Validated Stability-Indicating HPLC Method for the Determination of Mesna in Presence of Its Degradation Products
    Rizk, Mohamed
    Taha, Elham A.
    Mowaka, Shereen
    Abdallah, Youmna M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (05) : 742 - 748