Establishment of inherent stability on piracetam by UPLC/HPLC and development of a validated stability-indicating method

被引:4
|
作者
Sahu, Kapendra [1 ]
Shaharyar, Mohammad [1 ]
Siddiqui, Anees A. [1 ]
Sahu, Shikha [2 ]
机构
[1] Jamia Hamdard, Dept Pharmaceut Chem, Fac Pharm, New Delhi 110062, India
[2] Govt Autonomous Girls PG Coll Excellence, Dept Chem, Sagar 470002, Madhya Pradesh, India
关键词
Piracetam; Stress testing; Stability indicating assay; Validation; UPLC; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; STRESS DEGRADATION; ICH GUIDANCE; ASSAY;
D O I
10.1016/j.arabjc.2012.11.003
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel comparative force degradation UPLC assay method was developed and validated for Piracetam and its degradation products. Piracetam was subjected to acid (5M HCl), neutral (water) and alkaline (0.5 MNaOH) hydrolytic conditions at 80 degrees C, as well as to oxidative decomposition (H2O2) at room temperature. Photolytic studies were carried out by exposing this drug into sunlight (60,000-70,000 lux) for 2 d. Additionally, the solid drug was subjected to 50 degrees C for 60 days in a hot air oven for thermal degradation. The UPLC chromatographic separation was performed on Acquity UPLC BEH C18 column (1.7 mu m, 2.1 mm x 150 mm) using isocratic mode (ACN: water, 25: 75 v/v) at a flow rate of 0.15 mL min(-1) and HPLC chromatographic separation was achieved on phenomenex C18 using isocratic mode (ACN: 10 mM ammonium acetate, pH 5.0, 20: 80 v/v) at a flow rate of 0.9 mL/min. Piracetam was found to degrade only in the base and shows stable behavior under all stress conditions. The UPLC and HPLC linearity of the proposed method was investigated in the range of 10-50 mu g mL(-1). The r(2) value of UPLC and HPLC was found to be 0.999 and 0.999, respectively. Method detection limit (MDL) and Method quantification limit (MQL) were found to be 0.180 mu g mL(-1) and 1.10 mu g mL(-1) for UPLC and 0.500 mu g mL(-1) and 1.700 mu g mL(-1) for HPLC respectively. The % RSD values for intra-day and inter-day precision were < 1.2%, confirming that the method was sufficiently precise. The validation studies were carried out fulfilling ICH requirements. The developed method was simple, fast, accurate and precise and hence could be applied for routine quality control analysis of Piracetam in solid dosage forms. (C) 2012 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:S576 / S582
页数:7
相关论文
共 50 条
  • [21] Establishment of inherent stability of pramipexole and development of validated stability indicating LC-UV and LC-MS method
    Shubhangi M.Pawar
    Laxman D.Khatal
    Satish Y.Gabhe
    Sunil R.Dhaneshwar
    JournalofPharmaceuticalAnalysis, 2013, 3 (02) : 109 - 117
  • [22] Establishment of inherent stability of pramipexole and development of validated stability indicating LC-UV and LC-MS method
    Pawar, Shubhangi M.
    Khatal, Laxman D.
    Gabhe, Satish Y.
    Dhaneshwar, Sunil R.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2013, 3 (02) : 109 - 117
  • [23] A validated stability-indicating HPLC method for analysis of glabridin prodrugs in hydrolysis studies
    Jirawattanapong, Warunee
    Saifah, Ekarin
    Patarapanich, Chamnan
    DRUG DISCOVERIES AND THERAPEUTICS, 2009, 3 (03): : 97 - 103
  • [24] A validated stability-indicating HPLC method for the determination of PEGylated puerarin in aqueous solutions
    Liu, Xinyi
    Yu, Boyang
    Wang, Naijie
    Zhang, Bei
    Du, Feng
    He, Cheng
    Ye, Zuguang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (23): : 2061 - 2066
  • [25] A validated stability-indicating HPLC method for determination of varenicline in its bulk and tablets
    Kadi, Adnan A.
    Mohamed, Mostafa S.
    Kassem, Mohamed G.
    Darwish, Ibrahim A.
    CHEMISTRY CENTRAL JOURNAL, 2011, 5
  • [26] A validated HPLC stability-indicating method for the determination of diacerhein in bulk drug substance
    Giannellini, V
    Salvatore, F
    Bartolucci, G
    Coran, SA
    Bambagiotti-Alberti, M
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 776 - 780
  • [27] A VALIDATED, STABILITY-INDICATING HPLC METHOD FOR THE DETERMINATION OF FELODIPINE AND ITS RELATED SUBSTANCES
    Hu, Liandong
    Hu, Qiaofeng
    Gao, Na
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2013, 4 (09): : 3369 - 3374
  • [28] A validated stability-indicating HPLC method for determination of varenicline in its bulk and tablets
    Adnan A Kadi
    Mostafa S Mohamed
    Mohamed G Kassem
    Ibrahim A Darwish
    Chemistry Central Journal, 5
  • [29] A validated stability-indicating UPLC method for desloratadine and its impurities in pharmaceutical dosage forms
    Rao, Dantu Durga
    Satyanarayana, N. V.
    Reddy, A. Malleswara
    Sait, Shakil S.
    Chakole, Dinesh
    Mukkanti, K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (03) : 736 - 742
  • [30] Forced degradation of gliquidone and development of validated stability-indicating HPLC and TLC methods
    El-Ghobashy, Mohamed Refaat
    Yehia, Ali Mohamed
    Helmy, Aya Helmy
    Youssef, Nadia Fayek
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 54 (03)