Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer

被引:33
|
作者
Gao, Feng [1 ]
Liu, Hu [1 ]
Zhao, Qing [1 ]
Pan, Yingzhe [1 ]
机构
[1] Hubei Univ Med, Peoples Hosp Xiangyang 1, Dept Ophthalmol, 15 Jiefang Rd, Xiangyang 441000, Hubei, Peoples R China
关键词
iCare rebound tonometer; Goldmann applanation tonometry; intraocular pressure; central corneal thickness; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE; GLAUCOMA;
D O I
10.3892/etm.2017.4164
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7-15 mmHg, n=74; group B, 16-22 mmHg, n=218; and group C, 23-50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30 +/- 5.10 and 18.52 +/- 4.46 mmHg, respectively. There were no significant differences between them (t=-1.31, P=0.19). The 95% confidence interval of the differences between the two devices was -5.80-6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=-2.84, P=0.007) lower (-1.66 +/- 3.87 mmHg) than those obtained with GAT when GAT =23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.
引用
收藏
页码:1912 / 1916
页数:5
相关论文
共 50 条
  • [21] TONOMAT APPLANATION TONOMETER - A COMPARISON WITH GOLDMANN APPLANATION TONOMETER AND APPLANOMETER
    POSNER, A
    INGLIMA, R
    EYE EAR NOSE AND THROAT MONTHLY, 1969, 48 (03): : 189 - &
  • [22] Evaluation of rebound tonometer iCare IC200 as compared with IcarePRO and Goldmann applanation tonometer in patients with glaucoma
    Shunsuke Nakakura
    Ryo Asaoka
    Etsuko Terao
    Yuki Nagata
    Yasuko Fukuma
    Satomi Oogi
    Miku Shiraishi
    Yoshiaki Kiuchi
    Eye and Vision, 8
  • [23] Evaluation of rebound tonometer iCare IC200 as compared with IcarePRO and Goldmann applanation tonometer in patients with glaucoma
    Nakakura, Shunsuke
    Asaoka, Ryo
    Terao, Etsuko
    Nagata, Yuki
    Fukuma, Yasuko
    Oogi, Satomi
    Shiraishi, Miku
    Kiuchi, Yoshiaki
    EYE AND VISION, 2021, 8 (01)
  • [24] COMPARISON OF THE PULSAIR NONCONTACT TONOMETER AND THE GOLDMANN APPLANATION TONOMETER
    CLIMENHAGA, H
    PLUCINSKA, H
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1989, 24 (01): : 7 - 9
  • [25] Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer
    Sachdeva, Robin
    Iordanous, Yiannis
    Lin, Tony
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2023, 58 (05): : 426 - 432
  • [26] COMPARISON OF A NEW TONOMETER (PROTON) WITH THE GOLDMANN APPLANATION TONOMETER
    GRAF, M
    WASSILL, H
    DICK, B
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1995, 206 (04) : 255 - 261
  • [27] Comparison of IOP Measurement by Goldmann Applanation Tonometer, ICare Rebound Tonometer, and Tono-Pen in Keratoconus Patients after MyoRing Implantation
    Rateb, Mahmoud
    Abdel-Radi, Mahmoud
    Eldaly, Zeiad
    Elmohamady, Mohamed Nagy
    El Din, Asaad Noor
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [28] Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects
    Guler, Mete
    Bilak, Semsettin
    Bilgin, Burak
    Simsek, Ali
    Capkin, Musa
    Reyhan, Ali Hakim
    JOURNAL OF GLAUCOMA, 2015, 24 (08) : 613 - 618
  • [29] Comparison of Intraocular Pressure Measurements and Assessment of Intraobserver and Interobserver Reproducibility With the Portable ICare Rebound Tonometer and Goldmann Applanation Tonometer in Glaucoma Patients
    Salim, Sarwat
    Du, Haiming
    Wan, Jim
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 325 - 329
  • [30] Comparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in patients with glaucoma
    Vandewalle, Evelien
    Vandenbroeck, Sofie
    Stalmans, Ingeborg
    Zeyen, Thierry
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (05) : 783 - 789