Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer

被引:33
|
作者
Gao, Feng [1 ]
Liu, Hu [1 ]
Zhao, Qing [1 ]
Pan, Yingzhe [1 ]
机构
[1] Hubei Univ Med, Peoples Hosp Xiangyang 1, Dept Ophthalmol, 15 Jiefang Rd, Xiangyang 441000, Hubei, Peoples R China
关键词
iCare rebound tonometer; Goldmann applanation tonometry; intraocular pressure; central corneal thickness; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE; GLAUCOMA;
D O I
10.3892/etm.2017.4164
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7-15 mmHg, n=74; group B, 16-22 mmHg, n=218; and group C, 23-50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30 +/- 5.10 and 18.52 +/- 4.46 mmHg, respectively. There were no significant differences between them (t=-1.31, P=0.19). The 95% confidence interval of the differences between the two devices was -5.80-6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=-2.84, P=0.007) lower (-1.66 +/- 3.87 mmHg) than those obtained with GAT when GAT =23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.
引用
收藏
页码:1912 / 1916
页数:5
相关论文
共 50 条
  • [1] Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists
    L M Abraham
    N C R Epasinghe
    D Selva
    R Casson
    Eye, 2008, 22 : 503 - 506
  • [2] Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists
    Abraham, L. M.
    Epasinghe, N. C. R.
    Selva, D.
    Casson, R.
    EYE, 2008, 22 (04) : 503 - 506
  • [3] Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range
    Munkwitz, S.
    Elkarmouty, A.
    Hoffmann, E. M.
    Pfeiffer, N.
    Thieme, H.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (06) : 875 - 879
  • [4] Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range
    S. Munkwitz
    A. Elkarmouty
    E. M. Hoffmann
    N. Pfeiffer
    H. Thieme
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2008, 246 : 875 - 879
  • [5] Evaluation of a New Rebound Self-tonometer, Icare HOME: Comparison With Goldmann Applanation Tonometer
    Takagi, Daisuke
    Sawada, Akira
    Yamamoto, Tetsuya
    JOURNAL OF GLAUCOMA, 2017, 26 (07) : 613 - 618
  • [6] Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients
    Brusini, P
    Salvetat, ML
    Zeppieri, M
    Tosoni, C
    Parisi, L
    JOURNAL OF GLAUCOMA, 2006, 15 (03) : 213 - 217
  • [7] Comparison of Rebound Tonometer Icare-Pro and Goldmann Handheld Applanation Tonometer in Congenital Glaucoma
    Morales-Fernandez, Laura
    Borrego, Lara
    Martinez de la Casa, Jose
    Saenz-Frances, Federico
    Garcia-Feijoo, Julian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] Comparison of the rebound tonometer with the Goldmann applanation tonometer in glaucoma patients
    Sahin, Afsun
    Niyaz, Leyla
    Yildirim, Nilgun
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (04): : 335 - 339
  • [9] Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population
    Fernandes, P
    Díaz-Rey, JA
    Queirós, A
    Gonzalez-Meijome, JM
    Jorge, J
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (05) : 436 - 440
  • [10] Clinical comparison of the Icare tonometer and Goldmann applanation tonometry
    Pakrou, Nima
    Gray, Tim
    Mills, Richard
    Landers, John
    Craig, Jamie
    JOURNAL OF GLAUCOMA, 2008, 17 (01) : 43 - 47