Qualitative Assessment of Color M-Mode Signals in the Evaluation of Left Ventricular Diastolic Function: A Proof of Concept Study

被引:1
|
作者
Hernandez-Suarez, Dagmar F. [1 ]
Kim, Yeunjung [2 ]
Lopez, Francisco Menendez [3 ]
Ramakrishna, Harish [4 ]
Lopez-Candales, Angel [1 ]
机构
[1] Univ Puerto Rico, Sch Med, Cardiovasc Med Div, Med Sci Bldg,POB 365067, San Juan, PR 00936 USA
[2] Yale Univ, Sch Med, Dept Med, Div Cardiovasc Med, New Haven, CT 06510 USA
[3] Univ Cincinnati, Coll Med, Div Cardiovasc Hlth & Dis, Cincinnati, OH USA
[4] Mayo Clin, Div Cardiovasc & Thorac Anesthesiol, Phoenix, AZ USA
基金
美国国家卫生研究院;
关键词
diastolic function; color M-mode; qualitative assessment echocardiography; HEART-FAILURE; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; ECHOCARDIOGRAPHY; RECOMMENDATIONS; PROPAGATION; PROGNOSIS; UPDATE;
D O I
10.1053/j.jvca.2019.05.047
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: Although the most recent American Society of Echocardiography guidelines are a major step forward in echocardiographic evaluation of diastolic function, the ability to differentiate between normal and abnormal function remains challenging. The authors aimed to determine whether qualitative assessments of color M-mode flow displays could be a useful parameter in the evaluation of left ventricular (LV) diastolic dysfunction. Design: Retrospective observational study. Setting: Tertiary care level hospital. Participants: The study comprised echocardiographic data from 105 consecutive patients. Intervention: None. Measurements and Main Results: Patients were allocated into the following 3 groups according to the LV diastolic function based on current American Society of Echocardiography recommendation guidelines for LV diastolic dysfunction classification: group I-normal function (n = 40); group II-early relaxation abnormalities (grade I) (n = 50), and group Ill-elevated LV pressures (grade II) (n = 15). Patients with nor- mal diastolic function were younger (45 +/- 14 y) than those with diastolic dysfunction (group II: 64 +/- 10 y and group 56 +/- 15 y) (p < 0.05). Volumetric echocardiographic parameters and mitral inflow and mitral annulus tissue Doppler imaging measures were significantly different among the 3 studied groups (p < 0.05). Interestingly, qualitative assessment of color M-mode flows displayed distinctive signals based on the left ventricle filling properties. Intraobserver and interobserver variability to determine the reliability of these signals were robust (weighted kappa 0.84 +/- 0.11 and 0.65 +/- 0.13, respectively). Conclusion: Qualitative assessment of color M-mode flow displays offers simple and reliable information of potential usefulness in the evaluation of LV diastolic function. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2658 / 2662
页数:5
相关论文
共 50 条
  • [41] Influence of left ventricular systolic function on flow propagation during early diastolic filling assessed by color M-mode Doppler
    Dennig, K
    Haase, UH
    Schömig, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 465A - 465A
  • [42] Evaluation of beat-to-beat change in left ventricular diastolic function during atrial fibrillation by color M-mode (CMM) flow propagation velocity
    Han, PK
    Tabata, T
    Watanabe, J
    Cheong, B
    Greenberg, NL
    Klein, AL
    Thomas, JD
    Grimm, RA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 398A - 398A
  • [43] Abnormal left ventricular diastolic function and filling pressure in cardiomyopathic mice revealed by tissue Doppler and color M-mode Doppler echocardiography
    Tsujita, Y
    Kato, T
    Considine, K
    Sussman, MA
    CIRCULATION, 2003, 108 (17) : 277 - 277
  • [44] Assessment of left ventricular diastolic function in never-treated essential hypertensives: comparison of digitized M-mode and Doppler echocardiography
    Grandi, AM
    Imperiale, D
    Santillo, R
    Bertolini, A
    Broggi, R
    Colombo, S
    Selva, E
    Jessula, A
    Guasti, L
    Venco, A
    EUROPEAN HEART JOURNAL, 2000, 21 : 684 - 684
  • [45] Characteristics of left ventricular aneurysm by color M-mode echocardiography: A chronic animal study
    Watanabe, J
    Johns, M
    Shiota, T
    Tsujino, H
    Zetts, AD
    Qin, JX
    Cardon, LA
    Sitges, M
    Bauer, F
    Kim, YJ
    Garcia, MJ
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 418A - 418A
  • [46] Assessment of left Ventricular Function in Children with Myocardial Disease Using M-mode Echocardiography
    Tang Shengcai
    et al. Department of Pediatrics
    West China University of Medical Sciences
    华西医科大学学报, 1988, (02) : 127 - 127
  • [47] Anatomic M-mode: A new technique for quantitative assessment of left ventricular size and function
    Mele, D
    Pedini, I
    Alboni, P
    Levine, RA
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12A): : 82G - 85G
  • [48] Developmental changes in the left ventricular diastolic wall strain on M-mode echocardiography
    Suzue M.
    Mori K.
    Inoue M.
    Hayabuchi Y.
    Nakagawa R.
    Kagami S.
    Journal of Echocardiography, 2014, 12 (3) : 98 - 105
  • [49] EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN INSULIN-DEPENDENT DIABETIC CHILDREN BY M-MODE AND DOPPLER-ECHOCARDIOGRAPHY
    CERUTTI, F
    VIGO, A
    SACCHETTI, C
    BESSONE, A
    BARATTIA, G
    MORELLO, M
    CASALUCCI, D
    GASTALDI, L
    PANMINERVA MEDICA, 1994, 36 (03) : 109 - 114
  • [50] DIASTOLIC DISEASE IN LEFT-VENTRICULAR HYPERTROPHY - COMPARISON OF M-MODE AND DOPPLER ECHOCARDIOGRAPHY FOR THE ASSESSMENT OF RAPID VENTRICULAR FILLING
    LEE, CH
    HOGAN, JC
    GIBSON, DG
    BRITISH HEART JOURNAL, 1991, 65 (04): : 194 - 200