Qualitative Assessment of Color M-Mode Signals in the Evaluation of Left Ventricular Diastolic Function: A Proof of Concept Study

被引:1
|
作者
Hernandez-Suarez, Dagmar F. [1 ]
Kim, Yeunjung [2 ]
Lopez, Francisco Menendez [3 ]
Ramakrishna, Harish [4 ]
Lopez-Candales, Angel [1 ]
机构
[1] Univ Puerto Rico, Sch Med, Cardiovasc Med Div, Med Sci Bldg,POB 365067, San Juan, PR 00936 USA
[2] Yale Univ, Sch Med, Dept Med, Div Cardiovasc Med, New Haven, CT 06510 USA
[3] Univ Cincinnati, Coll Med, Div Cardiovasc Hlth & Dis, Cincinnati, OH USA
[4] Mayo Clin, Div Cardiovasc & Thorac Anesthesiol, Phoenix, AZ USA
基金
美国国家卫生研究院;
关键词
diastolic function; color M-mode; qualitative assessment echocardiography; HEART-FAILURE; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; ECHOCARDIOGRAPHY; RECOMMENDATIONS; PROPAGATION; PROGNOSIS; UPDATE;
D O I
10.1053/j.jvca.2019.05.047
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: Although the most recent American Society of Echocardiography guidelines are a major step forward in echocardiographic evaluation of diastolic function, the ability to differentiate between normal and abnormal function remains challenging. The authors aimed to determine whether qualitative assessments of color M-mode flow displays could be a useful parameter in the evaluation of left ventricular (LV) diastolic dysfunction. Design: Retrospective observational study. Setting: Tertiary care level hospital. Participants: The study comprised echocardiographic data from 105 consecutive patients. Intervention: None. Measurements and Main Results: Patients were allocated into the following 3 groups according to the LV diastolic function based on current American Society of Echocardiography recommendation guidelines for LV diastolic dysfunction classification: group I-normal function (n = 40); group II-early relaxation abnormalities (grade I) (n = 50), and group Ill-elevated LV pressures (grade II) (n = 15). Patients with nor- mal diastolic function were younger (45 +/- 14 y) than those with diastolic dysfunction (group II: 64 +/- 10 y and group 56 +/- 15 y) (p < 0.05). Volumetric echocardiographic parameters and mitral inflow and mitral annulus tissue Doppler imaging measures were significantly different among the 3 studied groups (p < 0.05). Interestingly, qualitative assessment of color M-mode flows displayed distinctive signals based on the left ventricle filling properties. Intraobserver and interobserver variability to determine the reliability of these signals were robust (weighted kappa 0.84 +/- 0.11 and 0.65 +/- 0.13, respectively). Conclusion: Qualitative assessment of color M-mode flow displays offers simple and reliable information of potential usefulness in the evaluation of LV diastolic function. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2658 / 2662
页数:5
相关论文
共 50 条
  • [21] Clincial utilty of color Doppler M-mode in the routine assessment of diastolic function
    Scalia, GM
    Melville, RE
    Burstow, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 418A - 418A
  • [22] STUDY OF LEFT-VENTRICULAR FUNCTION BY M-MODE ECHOCARDIOGRAPHY
    GIBSON, DG
    ACTA MEDICA SCANDINAVICA, 1979, : 87 - 92
  • [23] Application of color Doppler M-mode echocardiography in the assessment of ventricular diastolic function - Analysis of the spatiotemporal velocity distribution
    Thomas, JD
    Vandervoort, PM
    Greenberg, NL
    Ares, M
    Adams, MS
    SYSTOLIC AND DIASTOLIC FUNCTION OF THE HEART, 1996, 21 : 149 - 156
  • [24] Usefulness of early diastolic flow propagation velocity measured by color M-mode Doppler technique for the assessment of left ventricular diastolic function in patients with hypertrophic cardiomyopathy
    Nishihara, K
    Mikami, T
    Takatsuji, H
    Onozuka, H
    Saito, N
    Yamada, S
    Urasawa, K
    Kitabatake, A
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (09) : 801 - 808
  • [25] QUALITATIVE ASSESSMENT OF LEFT-VENTRICULAR FUNCTION BY 2 DIMENSIONAL VERSUS QUANTITATIVE ASSESSMENT BY M-MODE ECHOCARDIOGRAPHY
    STRATMANN, HG
    WILLIAMS, GA
    WALTER, KE
    CLINICAL RESEARCH, 1984, 32 (02): : A209 - A209
  • [26] Right and left ventricular diastolic dysfunction in patients with myocardial infarction:: A color M-mode analysis
    Selton-Suty, C
    Houplon, P
    Grentzinger, A
    Preiss, JP
    Jacquemin, L
    Angioï, M
    Juillière, Y
    Danchin, N
    Cherrier, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 296A - 296A
  • [27] COMPUTERIZED M-MODE ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS WITH FAMILIAL AMYLOID POLYNEUROPATHY
    HONGO, M
    MISAWA, T
    KINOSHITA, O
    YAMADA, H
    KONO, J
    OKUBO, S
    SEKIGUCHI, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1990, 54 (01): : 32 - 42
  • [28] M-MODE AND DOPPLER-ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PRIMARY ANTIPHOSPHOLIPID SYNDROME
    COUDRAY, N
    DEZUTTERE, D
    BLETRY, O
    PIETTE, JC
    WECHSLER, B
    GODEAU, P
    POURNY, JC
    LECARPENTIER, Y
    CHEMLA, D
    BRITISH HEART JOURNAL, 1995, 74 (05): : 531 - 535
  • [29] Progression of left ventricular diastolic function in the neonate and early childhood from transmitral color M-mode filling analysis
    Collin T. Erickson
    Brett Meyers
    Ling Li
    Mary Craft
    Vivek Jani
    John Bliamptis
    Karl Stessy Bisselou Moukagna
    David A. Danford
    Pavlos Vlachos
    Shelby Kutty
    Pediatric Research, 2021, 89 : 987 - 995
  • [30] 2-Dimensional Echocardiography and M-Mode Doppler of the Interatrial Septum for Assessment of Left Ventricular Diastolic Function
    Neema, Praveen Kumar
    Misra, Satyajeet
    Manikandan, Sethuraman
    Rathod, Ramesh Chandra
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 588 - 589