Phase imaging with multiple phase-cycled balanced steady-state free precession at 9.4T

被引:0
|
作者
Kim, Jae-Woong [1 ]
Kim, Seong-Gi [2 ,3 ]
Park, Sung-Hong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon, South Korea
[2] Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon, South Korea
[3] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
基金
新加坡国家研究基金会;
关键词
balanced steady-state free precession; functional MRI; gradient echo; high field; neuronal fiber; phase cycling; phase imaging; susceptibility; HIGH-FIELD MRI; HUMAN BRAIN; SUSCEPTIBILITY CONTRAST; BOLD SIGNALS; IRON CONTENT; SSFP FMRI; ECHO; RAT; SUPPRESSION; MICROSCOPY;
D O I
10.1002/nbm.3699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
While phase imaging with a gradient echo (GRE) sequence is popular, phase imaging with balanced steady-state free precession (bSSFP) has been underexplored. The purpose of this study was to investigate anatomical and functional phase imaging with multiple phase-cycled bSSFP, in expectation of increasing spatial coverage of steep phase-change regions of bSSFP. Eight different dynamic 2D pass-band bSSFP studies at four phase-cycling (PC) angles and two T-E/T-R values were performed on rat brains at 9.4T with electrical forepaw stimulation, in comparison with dynamic 2D GRE. Anatomical and functional phase images were obtained by averaging the dynamic phase images and mapping correlation between the dynamic images and the stimulation paradigm, and were compared with their corresponding magnitude images. Phase imaging with 3D pass-band and 3D transition-band bSSFP was also performed for comparison with 3D GRE phase imaging. Two strategies of combining the multiple phase-cycled bSSFP phase images were also proposed. Contrast between white matter and gray matter in bSSFP phase images significantly varied with PC angle and became twice as high as that of GRE phase images at a specific PC angle. With the same total scan time, the combined bSSFP phase images provided stronger phase contrast and visualized neuronal fiber-like structures more clearly than the GRE phase images. The combined phase images of both 3D pass-band and 3D transition-band bSSFP showed phase contrasts stronger than those of the GRE phase images in overall brain regions, even at a longer T-E of 20ms. In contrast, phase functional MRI (fMRI) signals were weak overall and mostly located in draining veins for both bSSFP and GRE. Multiple phase-cycled bSSFP phase imaging is a promising anatomical imaging technique, while its usage as fMRI does not seem desirable with the current approach.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Intrinsic diffusion sensitivity of the balanced steady-state free precession (bSSFP) imaging sequence
    Baer, Sebastien
    Weigel, Matthias
    von Elverfeldt, Dominik
    Hennig, Juergen
    Leupold, Jochen
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1383 - 1392
  • [32] Analytical Solution to the Transient Phase of Steady-State Free Precession Sequences
    Ganter, Carl
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 149 - 164
  • [33] Revisiting the Potential of Alternating Repetition Time Balanced Steady-State Free Precession Imaging of the Abdomen at 3 T
    Gurney-Champion, Oliver J.
    Nederveen, Aart J.
    Klaassen, Remy
    Engelbrecht, Marc R.
    Bel, Arjan
    van Laarhoven, Hanneke W. M.
    Stoker, Jaap
    Goncalves, Sonia I.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 560 - 568
  • [34] Phase-cycled balanced SSFP imaging for non-contrast-enhanced functional lung imaging
    Ilicak, Efe
    Ozdemir, Safa
    Schad, Lothar R.
    Weis, Meike
    Schoenberg, Stefan O.
    Zoellner, Frank G.
    Zapp, Jascha
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1764 - 1774
  • [35] Quantitative diffusion imaging with steady-state free precession
    Deoni, SCL
    Peters, TM
    Rutt, BK
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 428 - 433
  • [36] Phase-Cycled Simultaneous Multislice Balanced SSFP Imaging with CAIPIRINHA for Efficient Banding Reduction
    Wang, Yi
    Shao, Xingfeng
    Martin, Thomas
    Moeller, Steen
    Yacoub, Essa
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (06) : 1764 - 1774
  • [37] Flow effects in balanced steady state free precession imaging
    Markl, M
    Alley, MT
    Elkins, CJ
    Pelc, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 892 - 903
  • [38] Starter sequence for steady-state free precession imaging
    Foxall, DL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 919 - 929
  • [39] Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Robert R. Edelman
    Marcos Botelho
    Amit Pursnani
    Shivraman Giri
    Ioannis Koktzoglou
    Journal of Cardiovascular Magnetic Resonance, 18
  • [40] Positive susceptibility-based contrast imaging with dephased balanced steady-state free precession
    Faust, Jonas Frederik
    Speier, Peter
    Krafft, Axel Joachim
    Patil, Sunil
    Seethamraju, Ravi Teja
    Ladd, Mark E.
    Maier, Florian
    MAGNETIC RESONANCE IN MEDICINE, 2025,