Phase imaging with multiple phase-cycled balanced steady-state free precession at 9.4T

被引:0
|
作者
Kim, Jae-Woong [1 ]
Kim, Seong-Gi [2 ,3 ]
Park, Sung-Hong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon, South Korea
[2] Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon, South Korea
[3] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
基金
新加坡国家研究基金会;
关键词
balanced steady-state free precession; functional MRI; gradient echo; high field; neuronal fiber; phase cycling; phase imaging; susceptibility; HIGH-FIELD MRI; HUMAN BRAIN; SUSCEPTIBILITY CONTRAST; BOLD SIGNALS; IRON CONTENT; SSFP FMRI; ECHO; RAT; SUPPRESSION; MICROSCOPY;
D O I
10.1002/nbm.3699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
While phase imaging with a gradient echo (GRE) sequence is popular, phase imaging with balanced steady-state free precession (bSSFP) has been underexplored. The purpose of this study was to investigate anatomical and functional phase imaging with multiple phase-cycled bSSFP, in expectation of increasing spatial coverage of steep phase-change regions of bSSFP. Eight different dynamic 2D pass-band bSSFP studies at four phase-cycling (PC) angles and two T-E/T-R values were performed on rat brains at 9.4T with electrical forepaw stimulation, in comparison with dynamic 2D GRE. Anatomical and functional phase images were obtained by averaging the dynamic phase images and mapping correlation between the dynamic images and the stimulation paradigm, and were compared with their corresponding magnitude images. Phase imaging with 3D pass-band and 3D transition-band bSSFP was also performed for comparison with 3D GRE phase imaging. Two strategies of combining the multiple phase-cycled bSSFP phase images were also proposed. Contrast between white matter and gray matter in bSSFP phase images significantly varied with PC angle and became twice as high as that of GRE phase images at a specific PC angle. With the same total scan time, the combined bSSFP phase images provided stronger phase contrast and visualized neuronal fiber-like structures more clearly than the GRE phase images. The combined phase images of both 3D pass-band and 3D transition-band bSSFP showed phase contrasts stronger than those of the GRE phase images in overall brain regions, even at a longer T-E of 20ms. In contrast, phase functional MRI (fMRI) signals were weak overall and mostly located in draining veins for both bSSFP and GRE. Multiple phase-cycled bSSFP phase imaging is a promising anatomical imaging technique, while its usage as fMRI does not seem desirable with the current approach.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Use of simulated annealing for the design of multiple repetition time balanced steady-state free precession imaging
    Lee, Kuan J.
    Lee, Hsu-Lei
    Hennig, Juergen
    Leupold, Jochen
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 220 - 226
  • [22] Fat-suppressed steady-state free precession imaging using phase detection
    Hargreaves, BA
    Vasanawala, SS
    Nayak, KS
    Hu, BS
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 210 - 213
  • [23] Dynamically Phase-Cycled Radial Balanced SSFP Imaging for Efficient Banding Removal
    Benkert, Thomas
    Ehses, Philipp
    Blaimer, Martin
    Jakob, Peter M.
    Breuer, Felix A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 182 - 194
  • [24] Diffusion Imaging with Balanced Steady State Free Precession
    Cheung, Matthew M.
    Wu, Ed X.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 90 - 93
  • [25] Improved cerebrospinal fluid flow measurements using phase contrast balanced steady-state free precession
    McCormack, Erin J.
    Egnor, Michael R.
    Wagshul, Mark E.
    MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 172 - 182
  • [26] On the application of balanced steady-state free precession to MR microscopy
    Baer, Sebastien
    Oerther, Thomas
    Weigel, Matthias
    Mueller, Angelina
    Hucker, Patrick
    Korvink, Jan G.
    Ko, Cheng-Wen
    Wapler, Matthias C.
    Leupold, Jochen
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (04) : 437 - 447
  • [27] FMRI using balanced steady-state free precession (SSFP)
    Miller, Karla L.
    NEUROIMAGE, 2012, 62 (02) : 713 - 719
  • [28] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [29] Getting the phase consistent: The importance of phase description in balanced steady-state free precession MRI of multi-compartment systems
    Plahn, Nils M. J.
    Poli, Simone
    Peper, Eva S.
    Acikgoz, Berk C.
    Kreis, Roland
    Ganter, Carl
    Bastiaansen, Jessica A. M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (01) : 215 - 225
  • [30] On the application of balanced steady-state free precession to MR microscopy
    Sébastien Bär
    Thomas Oerther
    Matthias Weigel
    Angelina Müller
    Patrick Hucker
    Jan G. Korvink
    Cheng-Wen Ko
    Matthias C. Wapler
    Jochen Leupold
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 437 - 447