Evaluating the impact of x-ray spectral shape on image quality in flat-panel CT breast imaging

被引:48
|
作者
Glick, Stephen J. [1 ]
Thacker, Samta
Gong, Xing
Liu, Bob
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02172 USA
[3] Rush Univ, Med Ctr, Dept Med Phys & Radiat Oncol, Chicago, IL 60612 USA
[4] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
D O I
10.1118/1.2388574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years, there has been an increasing interest in exploring the feasibility of dedicated computed tomography (CT) breast imaging using a flat-panel digital detector in a truncated cone-beam imaging, geometry. Preliminary results are promising and it appears as if three-dimensional tomographic imaging of the breast has great potential for reducing the masking effect of superimposed parenchymal structure typically observed with conventional mammography. In this study, a mathematical framework used for determining optimal design and acquisition parameters for such a CT breast imaging system is described. The ideal observer signal-to-noise ratio (SNR) is used as a figure of merit, under the assumptions that the imaging system is linear and shift invariant. Computation of the ideal observer SNR used a parallel-cascade model to predict signal and noise propagation through the detector, as well as a realistic model of the lesion detection task in breast imaging. For all evaluations, the total mean glandular dose for a CT breast imaging study was constrained to be approximately equivalent to that of a two-view conventional mammography study. The framework presented was used to explore the effect of x-ray spectral shape across an extensive ran-e of kVp settings, filter material types, and filter thicknesses. The results give an indication of how spectral shape can affect image quality in flat-panel CT breast imaging. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:5 / 24
页数:20
相关论文
共 50 条
  • [41] Development of flat panel X-ray image sensors
    Izumi, Y.
    Teranuma, O.
    Sato, T.
    Uehara, K.
    Okada, H.
    Tokuda, S.
    Sato, T.
    Shapu Giho/Sharp Technical Journal, 2001, (80): : 25 - 30
  • [42] Determination of point spread function for a flat-panel X-ray imager and its application in image restoration
    Jeon, Sungchae
    Cho, Gyuseong
    Huh, Young
    Jin, Seungoh
    Park, Jongduk
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 167 - 171
  • [43] Flat-panel X-ray Image Sensor Using Thin Film Transistors and Field Emitter Arrays
    Zhao, W.
    Rowlands, J. A.
    2013 INTERNATIONAL CONFERENCE ON SEMICONDUCTOR TECHNOLOGY FOR ULTRA LARGE SCALE INTEGRATED CIRCUITS AND THIN FILM TRANSISTORS (ULSIC VS. TFT 4), 2013, 54 (01): : 305 - 309
  • [44] Investigation of time-resolved proton radiography using x-ray flat-panel imaging system
    Jee, K-W
    Zhang, R.
    Bentefour, E. H.
    Doolan, P. J.
    Cascio, E.
    Sharp, G.
    Flanz, J.
    Lu, H-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05): : 1905 - 1919
  • [45] Real-time flat-panel pixel imaging system and control for X-ray and neutron detection
    Chapuy, S
    Dimcovski, M
    Dimcovski, Z
    Lehmann, EH
    Pachoud, M
    Valley, JF
    Verdun, FR
    Vontobel, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2357 - 2364
  • [46] Performance quantification of a flat-panel imager in industrial mega-voltage X-ray imaging systems
    Stritt, Carina
    Plamondon, Mathieu
    Hofmann, Jurgen
    Fliseh, Alexander
    Sennhauser, Urs
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 848 : 73 - 80
  • [47] Optimisation of radiological protocols for chest imaging using computed radiography and flat-panel X-ray detectors
    Compagnone, G.
    Baleni, M. Casadio
    Di Nicola, E.
    Valentino, M.
    Benati, M.
    Calzolaio, L. F.
    Oberhofer, N.
    Fabbri, E.
    Domenichelli, S.
    Barozzi, L.
    RADIOLOGIA MEDICA, 2013, 118 (04): : 540 - 554
  • [48] Image quality evaluation of flat panel and image intensifier digital magnification in x-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    MEDICAL PHYSICS, 2002, 29 (07) : 1611 - 1621
  • [49] Addressable flat-panel x-ray sources for medical, security and industrial applications
    Travish, Gil
    Rangel, Felix. J.
    Evans, Mark Andrew
    Hollister, Ben
    Schmiedehausen, Kristin
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VII, 2012, 8502
  • [50] Characterization of a flat-panel amorphous silicon detector for X-ray computed tomography
    Lee, H.-R.
    Ellingson, W.