Evaluating the impact of x-ray spectral shape on image quality in flat-panel CT breast imaging

被引:48
|
作者
Glick, Stephen J. [1 ]
Thacker, Samta
Gong, Xing
Liu, Bob
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02172 USA
[3] Rush Univ, Med Ctr, Dept Med Phys & Radiat Oncol, Chicago, IL 60612 USA
[4] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
D O I
10.1118/1.2388574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years, there has been an increasing interest in exploring the feasibility of dedicated computed tomography (CT) breast imaging using a flat-panel digital detector in a truncated cone-beam imaging, geometry. Preliminary results are promising and it appears as if three-dimensional tomographic imaging of the breast has great potential for reducing the masking effect of superimposed parenchymal structure typically observed with conventional mammography. In this study, a mathematical framework used for determining optimal design and acquisition parameters for such a CT breast imaging system is described. The ideal observer signal-to-noise ratio (SNR) is used as a figure of merit, under the assumptions that the imaging system is linear and shift invariant. Computation of the ideal observer SNR used a parallel-cascade model to predict signal and noise propagation through the detector, as well as a realistic model of the lesion detection task in breast imaging. For all evaluations, the total mean glandular dose for a CT breast imaging study was constrained to be approximately equivalent to that of a two-view conventional mammography study. The framework presented was used to explore the effect of x-ray spectral shape across an extensive ran-e of kVp settings, filter material types, and filter thicknesses. The results give an indication of how spectral shape can affect image quality in flat-panel CT breast imaging. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:5 / 24
页数:20
相关论文
共 50 条
  • [21] IQI-sensitivity and applications of flat-panel detectors and X-ray image intensifiers - a comparison
    Purschke, M
    INSIGHT, 2002, 44 (10) : 628 - 630
  • [22] IQI-sensitivity and applications of flat-panel detectors and X-ray image intensifiers - A comparison
    Purschke, Matthias
    Insight: Non-Destructive Testing and Condition Monitoring, 2002, 44 (10): : 628 - 630
  • [23] Dynamic Properties of Flat-Panel X-Ray Image Sensors With Mercury Iodide Photoconductors Undergoing Repeated X-Ray Irradiation
    Park, Jae Chul
    Ahn, Seung-Eon
    IEEE JOURNAL OF THE ELECTRON DEVICES SOCIETY, 2017, 5 (05): : 400 - 403
  • [24] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [25] The use of a flat-panel detector for seven-beam x-ray coherent scatter imaging
    Foran, Kelly A.
    Johns, Paul C.
    MEDICAL PHYSICS, 2017, 44 (08) : 4377 - 4377
  • [26] Medical imaging with mercuric iodide direct digital radiography flat-panel X-ray detectors
    Schieber, M
    Hermon, H
    Zentai, G
    Partain, L
    Street, RA
    Gilboa, H
    RADIOLOGY, 2001, 221 : 464 - 464
  • [27] Medical imaging with mercuric iodide direct digital radiography flat-panel X-ray detectors
    Gilboa, H
    Zuck, A
    Dagan, O
    Vilensky, A
    Breen, BN
    Taieb, A
    Reisman, B
    Hermon, H
    Zentai, G
    Partain, L
    Street, R
    Ready, S
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 315 - 325
  • [28] Optimal x-ray imaging geometry for flat-panel cone-beam computed tomography
    Siewerdsen, JH
    Jaffray, DA
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 106 - 107
  • [29] X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays
    Munro, P
    Bouius, DC
    MEDICAL PHYSICS, 1998, 25 (05) : 689 - 702
  • [30] Comparison of image quality using a X-ray stereotactical whole-body system and a direct flat-panel X-ray device in examinations of the pelvis and knee
    Krug, K. B.
    Weber, C.
    Schwabe, H.
    Sinzig, N. -M.
    Wein, B.
    Mueller, D.
    Wegmann, K.
    Peters, S.
    Sendler, V.
    Ewen, K.
    Hellmich, M.
    Maintz, D.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (01): : 67 - 76