A comparison of conventional versus locking plates in intraarticular calcaneus fractures: A biomechanical study in human cadavers

被引:51
|
作者
Stoffel, Karl
Booth, Grant
Rohrl, Stephan M.
Kuster, Markus
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle, WA 6160, Australia
[2] Kantonsspital St Gallen, Dept Orthopaed, CH-9007 St Gallen, Switzerland
关键词
calcaneal fracture; plate fixation; locked screws; conventional screws; biomechanical testing;
D O I
10.1016/j.clinbiomech.2006.07.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Internal fixation of displaced intraarticular calcaneal fractures in patients older than 50 years remains controversial. This is, in many cases, due to fear of loss of fixation and the risk of implant failure in osteoporotic bone. It is the objective of this study to compare the fixation strength obtained using calcaneal plates with and without locking screws, in the fixation of osteoporotic cadaveric intraarticular calcaneal fractures. Methods. In seven pairs of fresh frozen lower limbs cadavers, intraarticular calcaneal fractures were created with a dynamic single impact loading device and stabilized using either the low profile locking plate, or the conventional calcaneus plate. Radiographs were obtained to assess reduction. The specimens were then subjected to cyclic loading followed by loading to failure, using matched pairs of cadaveric lower limbs. The Wilcoxon signed rank test was used to test for differences in the results. Findings. The locking plate showed a significant lower irreversible deformation during cyclic loading and a significant higher load to failure. The difference between the ultimate displacement, and work to failure was not significant. A low bone mineral content in the area of the posterior facet correlated only in the conventional plate group with increased irreversible deformation. Interpretation. This study supports the mechanical viability of using locking calcancal plates for the fixation of intraarticular calcaneal fractures in elderly patients. Crown Copyright (c) 2006 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [31] Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures:: A biomechanical study
    Müller, LP
    Prommersberger, KJ
    Mehler, D
    Krummenauer, F
    Rommens, PM
    PROCEEDINGS OF THE 9TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR SURGERY OF THE HAND, 2004, : 571 - 576
  • [32] Outcomes of Pin and Plaster Versus Locking Plate in Distal Radius Intraarticular Fractures
    Bahari-Kashani, Mahmoud
    Taraz-Jamshidy, Mohammad Hosein
    Rahimi, Hassan
    Ashraf, Hami
    Mirkazemy, Masoud
    Fatehi, Amirreza
    Asadian, Mariam
    Rezazade, Jafar
    TRAUMA MONTHLY, 2013, 17 (04) : 380 - 385
  • [33] Locking intramedullary nails versus locking plates for the treatment of proximal humerus fractures
    Gracitelli, Mauro E. C.
    Malavolta, Eduardo A.
    Assuncao, Jorge H.
    Ferreira Neto, Arnaldo A.
    Silva, Jorge S.
    Hernandez, Arnaldo Jose
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (09) : 733 - 739
  • [34] Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study
    Dietz, Sven-Oliver
    Hartmann, Frank
    Schwarz, Thomas
    Nowak, Tobias E.
    Enders, Annalisa
    Kuhn, Sebastian
    Hofmann, Alexander
    Rommens, Pol Maria
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (05) : 618 - 624
  • [35] A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation
    Mehin, Ramin
    Jones, Bryn
    Zhu, Qingan
    Broekhuyse, Henry
    CANADIAN JOURNAL OF SURGERY, 2009, 52 (03) : 221 - 228
  • [36] Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures
    Otto, Randall J.
    Moed, Berton R.
    Bledsoe, J. Gary
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 645 - 652
  • [37] Comparison Between Conventional and Variable-Angle Locking Compression Plates in Complex Proximal Tibia Fractures
    Singh, Prashant P.
    Kumar, Sunil
    Kumar, Dinesh
    Gupta, Pradeep K.
    Joshi, Sanjeev
    Kumar, Rajeev
    Kumar, Harish
    Deen, Gaya
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [38] Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures
    Doht, Stefanie
    Meffert, Rainer H.
    Raschke, Michael J.
    Blunk, Torsten
    Ochman, Sabine
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [39] Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes
    Padolino A.
    Porcellini G.
    Guollo B.
    Fabbri E.
    Kiran Kumar G.N.
    Paladini P.
    Merolla G.
    MUSCULOSKELETAL SURGERY, 2018, 102 (Suppl 1) : 49 - 56
  • [40] Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: A cadaveric model
    Dougherty, Paul J.
    Kim, Do-Gyoon
    Meisterling, Steve
    Wybo, Christopher
    Yeni, Yener
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (06) : 399 - 403