A comparison of conventional versus locking plates in intraarticular calcaneus fractures: A biomechanical study in human cadavers

被引:51
|
作者
Stoffel, Karl
Booth, Grant
Rohrl, Stephan M.
Kuster, Markus
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle, WA 6160, Australia
[2] Kantonsspital St Gallen, Dept Orthopaed, CH-9007 St Gallen, Switzerland
关键词
calcaneal fracture; plate fixation; locked screws; conventional screws; biomechanical testing;
D O I
10.1016/j.clinbiomech.2006.07.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Internal fixation of displaced intraarticular calcaneal fractures in patients older than 50 years remains controversial. This is, in many cases, due to fear of loss of fixation and the risk of implant failure in osteoporotic bone. It is the objective of this study to compare the fixation strength obtained using calcaneal plates with and without locking screws, in the fixation of osteoporotic cadaveric intraarticular calcaneal fractures. Methods. In seven pairs of fresh frozen lower limbs cadavers, intraarticular calcaneal fractures were created with a dynamic single impact loading device and stabilized using either the low profile locking plate, or the conventional calcaneus plate. Radiographs were obtained to assess reduction. The specimens were then subjected to cyclic loading followed by loading to failure, using matched pairs of cadaveric lower limbs. The Wilcoxon signed rank test was used to test for differences in the results. Findings. The locking plate showed a significant lower irreversible deformation during cyclic loading and a significant higher load to failure. The difference between the ultimate displacement, and work to failure was not significant. A low bone mineral content in the area of the posterior facet correlated only in the conventional plate group with increased irreversible deformation. Interpretation. This study supports the mechanical viability of using locking calcancal plates for the fixation of intraarticular calcaneal fractures in elderly patients. Crown Copyright (c) 2006 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [21] A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    Korner, J
    Diederichs, G
    Arzdorf, M
    Lill, H
    Josten, C
    Schneider, E
    Linke, B
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (05) : 286 - 293
  • [22] A biomechanical comparison of posterior malleolar fracture fixation using screws and locking plates in Trimalleolar fractures: a finite element study
    Chang, Chih-Wei
    Chen, Yen-Nien
    Jhong, Guan-Heng
    Su, Kuo-Chih
    Li, Chun-Ting
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [23] Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
    Ramos Gloria, Jose Cristiano
    Fernandes, Ighor Andrade
    da Silveira, Esmeralda Maria
    de Souza, Glaciele Maria
    Rocha, Ricardo Lopes
    Galvao, Endi Lanza
    Moreira Falci, Saulo Gabriel
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2018, 22 (02) : 181 - 189
  • [24] Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
    Erden, Tunay
    Kapicioglu, Mehmet
    Demirtas, Abdullah
    Bilsel, Kerem
    Akpinar, Fuat
    Kuduz, Hacer
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2019, 53 (06) : 490 - 496
  • [25] Volar versus dorsal latest-generation variable-angle locking plates for the fixation of AO type 23C 2.1 distal radius fractures: A biomechanical study in cadavers
    Rausch, Sascha
    Schlonski, Olaf
    Klos, Kajetan
    Gras, Florian
    Gueorguiev, Boyko
    Hofmann, Gunther O.
    Mueckley, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 523 - 526
  • [26] Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: A biomechanical study
    Trease, C
    McIff, T
    Toby, EB
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 756 - 763
  • [27] Biomechanical analysis of a novel locking plate with smooth pegs versus a conventional locking plate with threaded screws for proximal humerus fractures
    Yamamoto, Nobuyuki
    Hongo, Michio
    Berglund, Lawrence J.
    Sperling, John W.
    Cofield, Robert H.
    An, Kai-Nan
    Steinmann, Scott P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (04) : 445 - 450
  • [28] Fixation of distal clavicle fractures with coracoclavicular instability - A comparative biomechanical study in human cadavers
    Laux, Christoph J.
    Borbas, Paul
    Villefort, Christina
    Hofstede, Simon
    Ernstbrunner, Lukas
    Wieser, Karl
    SWISS MEDICAL WEEKLY, 2021, 151 : 11S - 11S
  • [29] Stiffness of Locking and Conventional Plates in Fixation of Distal Fibula Fractures; A Finite Element Study
    Patel, Bipin
    Gustafson, Peter A.
    Jastifer, James
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 2, 2012, : 439 - +
  • [30] Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures:: A biomechanical study
    Mueller, L. P.
    Klitscher, D.
    Rudig, L.
    Mehler, D.
    Rommens, P. M.
    Prommersberger, K. J.
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2006, 31B (05): : 556 - 561